Complete Test Sequence

The purpose of this sequence is to perform a full suite of basic measurements for a loudspeaker. A 500 mV stepped sine sweep from 20 kHz to 50 Hz is played through the speaker and measured via two channels of the audio interface. A calibrated reference microphone is connected to one of the channels, and an impedance reference is connected to the other.

A HarmonicTrak™ analysis step analyzes the recorded waveform from the reference microphone, and outputs frequency response, THD, Rub & Buzz, and various harmonic curves. A second analysis step analyzes the waveform from the impedance reference and outputs a curve of impedance versus frequency. A post processing step is used to estimate the characteristics of the impedance curve and calculates the max impedance, resonance frequency, and the Q of the resonance peak.