{"id":3591,"date":"2015-06-03T16:15:17","date_gmt":"2015-06-03T16:15:17","guid":{"rendered":"https:\/\/www.listeninc.com\/zh-hans\/new-features-by-version\/"},"modified":"2026-11-09T15:44:35","modified_gmt":"2026-11-09T19:44:35","slug":"new-features-by-version","status":"publish","type":"page","link":"https:\/\/www.listeninc.com\/zh-hans\/new-features-by-version\/","title":{"rendered":"SoundCheck New Features"},"content":{"rendered":"<div id='layer_slider_1'  class='avia-layerslider main_color avia-shadow  avia-builder-el-0  el_before_av_one_full  avia-builder-el-first  container_wrap sidebar_right'  style='height: 234px; max-width: 1610px; margin: 0 auto;'  ><\/div><div id='after_layer_slider_1'  class='main_color av_default_container_wrap container_wrap sidebar_right'  ><div class='container av-section-cont-open' ><div class='template-page content  av-content-small alpha units'><div class='post-entry post-entry-type-page post-entry-3591'><div class='entry-content-wrapper clearfix'>\n<div  class='flex_column av-18ycq50-60b63022eb5a2632b8752506a8d76936 av_one_full  avia-builder-el-1  el_after_av_layerslider  el_before_av_one_full  avia-builder-el-first  first flex_column_div  '     ><section  class='av_textblock_section av-18486xg-7078bb0ad5e22f530668adba307d8af1 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><h1>SoundCheck: What&#8217;s New?<\/h1>\n<h3>A summary of new features by version<\/h3>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-16gkk44-753ba37e3d38181daec53e0888056600 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p>A new version of SoundCheck is released each year. New features range from the inclusion of new algorithms, to improved functionality, tighter integration with hardware, and improved user interface.<\/p>\n<p>Scroll through the list below to learn about new features by release.<\/p>\n<\/div><\/section><\/p><\/div>\n<div  class='flex_column av-av_one_full-048119fdb636ea3d70edc0b975509c6c av_one_full  avia-builder-el-4  el_after_av_one_full  el_before_av_one_full  first flex_column_div  column-top-margin'     ><section  class='av_textblock_section av-mw9nqzdm-cd144b924b0559e08ae6a4ce7b8bfff8 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><h1>Why Upgrade SoundCheck?<\/h1>\n<h3>Is your SoundCheck system keeping pace with your measurement needs?<\/h3>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-mw9nxcr1-1226dab784c7de908e5f958bde9ceb20 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><iframe loading=\"lazy\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/ipOPmeaWs2Q?si=llxhfCg81zU6M32u\" width=\"400\" height=\"225\" frameborder=\"0\" align=\"right\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n<p style=\"text-align: left;\"><em><strong>If you&#8217;re using an older version of SoundCheck, you may be missing out on capabilities that could make your testing faster, easier, and more effective. The past few releases bring some significant changes ranging from new perceptual measurement techniques to faster sequence development and easier integration into both R&amp;D and production environments. Watch the video for a look at the highlights.<\/strong><\/em><\/p>\n<\/div><\/section><br \/>\n<div  class='hr av-av_hr-91d7ccd583a503147498e120fee2ff9b hr-default  avia-builder-el-7  el_after_av_textblock  avia-builder-el-last '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><\/p><\/div><div  class='flex_column av-4x6nic-ea70444349649db2966e3efbd902215c av_one_full  avia-builder-el-8  el_after_av_one_full  el_before_av_one_full  first flex_column_div  column-top-margin'     ><section  class='av_textblock_section av-mrjg8cqe-4c472bf3a7727ff663e6b81f8ea13c0f '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>SoundCheck New Features: Version 24 (2026)<\/h3>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-mrjgan9q-d9aad3194fdd521d8c40373ca9388a52 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><iframe loading=\"lazy\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/I9VQffTWecU\" width=\"400\" height=\"225\" frameborder=\"0\" align=\"right\" allowfullscreen=\"allowfullscreen\"><\/iframe><em><strong>SoundCheck 24 shortens test development time and improves ease of use. A new streamlined interface enables quick measurements without configuring test sequences. Calibration and graphing updates accelerate workflow, and new algorithms and displays increase the capabilities of your system.<\/strong><\/em><\/p>\n<\/div><\/section><br \/>\n<div  class='hr av-1v96dg-d03412b4be441b0150794bf61d3418af hr-default  avia-builder-el-11  el_after_av_textblock  el_before_av_textblock '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n<section  class='av_textblock_section av-mrjgd0o7-cf7b68aa285e5169a9c1d31875f57eec '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><b>FastTrak <\/b><span style=\"font-weight: 400;\">FastTrak is a new, streamlined interface for quick measurements with SoundCheck and Listen audio interfaces. It accelerates the learning curve and offers rapid data collection and comparison without the overhead of<img decoding=\"async\" class=\"size-medium wp-image-21576 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/FastTrak-300x220.jpg\" alt=\"\" width=\"300\" height=\"220\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/FastTrak-300x220.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/FastTrak-1300x952.jpg 1300w, https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/FastTrak-768x562.jpg 768w, https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/FastTrak-705x516.jpg 705w, https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/FastTrak.jpg 1446w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/> full sequence development. The entire test setup is managed from a single window, including hardware selection and configuration, microphone calibration, stimulus configuration, and measurement selection. Basic measurements such as frequency response, total harmonic distortion (THD), and rub and buzz are made using stepped sine or logarithmic sweep signals, and displayed on screen. Data can be saved and FastTrack tests can be exported to regular SoundCheck sequences if customization or additional test capabilities are required. This feature is initially focused on loudspeaker testing, with additional applications coming soon.<\/span><\/p>\n<p><b>Streamlined Calibration Interface <\/b><span style=\"font-weight: 400;\">Calibration Profiles increase flexibility and ease-of-use when managing calibrated devices and signal paths across multiple test environments. Profiles can be created for different test rooms, fixtures, operators, or measurement applications. Each profile can assign different calibrated devices to the same signal path names, allowing the same sequences to be reused without modification while calibration assignments change. This avoids duplicating signal paths or manually changing calibration assignments when switching hardware. Profiles can also include only the signal paths required for a particular application, reducing clutter in Virtual Instruments and simplifying navigation.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">A new unified interface streamlines calibration by combining the calibration table and signal path views into a single window. Selecting any signal path immediately displays its configuration for editing, making it faster to review<img decoding=\"async\" class=\"size-medium wp-image-21580 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Headphone_Calibration_Profile-300x181.jpg\" alt=\"\" width=\"300\" height=\"181\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Headphone_Calibration_Profile-300x181.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Headphone_Calibration_Profile-768x463.jpg 768w, https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Headphone_Calibration_Profile-705x425.jpg 705w, https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Headphone_Calibration_Profile.jpg 1267w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/> and modify system settings without switching between views. New multi-selection options allow changes to be applied more efficiently across multiple signal paths, and additional context menu commands further simplify common workflows. A particularly valuable addition is \u2018Read All TEDS Microphones\u2019, which automatically reads TEDS information from every connected TEDS-enabled microphone and assigns the appropriate calibrated devices to their corresponding signal paths. Also new is the ability to calibrate any device in an open sequence directly from the setup menu.<\/span><\/p>\n<p><b>Directivity Plots (p\/n 2011 required) <\/b><span style=\"font-weight: 400;\">Directivity Plots provide a new way to visualize directional measurement data. In addition to the traditional polar plot, showing level versus<img decoding=\"async\" class=\"size-medium wp-image-21570 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Screenshot-directivity-300x183.png\" alt=\"\" width=\"300\" height=\"183\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Screenshot-directivity-300x183.png 300w, https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Screenshot-directivity-1300x795.png 1300w, https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Screenshot-directivity-768x470.png 768w, https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Screenshot-directivity-1536x939.png 1536w, https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Screenshot-directivity-1500x917.png 1500w, https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Screenshot-directivity-705x431.png 705w, https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Screenshot-directivity.png 2030w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/> angle at selected frequencies, a Directivity Plot displays frequency on the x-axis and angle on the y-axis, with color representing the measured level. This shows the complete frequency and angular response at a glance, making it easier to identify directional behavior or areas of interest. The Polar Plot and Directivity Plot are fully synchronized; dragging cursors in a Directivity Plot automatically updates the Polar Plot frequency slices for more detail.<\/span><\/p>\n<p><b>Multi-Instrument Enhancements\u00a0<\/b><\/p>\n<p><span style=\"font-weight: 400;\">New Multi-instrument functionality includes:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">A new Power Sum calculation to measure the overall level of a power-averaged spectrum in real time. This is useful for multi-channel<img decoding=\"async\" class=\"size-medium wp-image-21568 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Power_Sum-300x150.png\" alt=\"\" width=\"300\" height=\"150\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Power_Sum-300x150.png 300w, https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Power_Sum-768x383.png 768w, https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Power_Sum-705x352.png 705w, https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Power_Sum.png 1068w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/> applications such as automotive measurements, where the head unit\u2019s volume level needs to be adjusted to a target sound level.\u00a0<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">A new Track Maximum cursor automatically follows the dominant peak as it moves. The harmonic cursors will also update relative to the new peak , making it easy to monitor harmonics and THD in real time.\u00a0<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">A new method for handling grouped measurements in the multi-instrument for faster test development.<\/span><\/li>\n<\/ul>\n<p><b>Enhanced Graph Legends and Curve Display <\/b><span style=\"font-weight: 400;\">Graph legends may now be placed anywhere inside the graph area, allowing more screen space for the graph, while still keeping the<img decoding=\"async\" class=\"size-medium wp-image-21582 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Legend_in_graph-300x181.jpg\" alt=\"\" width=\"300\" height=\"181\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Legend_in_graph-300x181.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Legend_in_graph-768x463.jpg 768w, https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Legend_in_graph-705x425.jpg 705w, https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Legend_in_graph.jpg 1109w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/> legend visible. Curves can also instantly be shown or hidden by checking or unchecking the box next to each trace on the legend. This makes it faster to compare measurements, isolate individual traces, or temporarily hide outliers.<\/span><\/p>\n<p><b>Updated Harmonic Analysis Options <\/b><span style=\"font-weight: 400;\">Outputting harmonics to the memory list can now be suppressed, but still used for calculations such as THD and Rub &amp; Buzz. This keeps the Memory List focused and clean, especially in applications with high channel counts or when analyzing many harmonics for Rub &amp; Buzz calculations. Harmonic analysis minimum and maximum frequencies can also be set to restrict\u00a0the range of harmonics that are included in analysis calculations such as THD.<\/span><\/p>\n<p><b>Algorithm Enhancements\u00a0<\/b><\/p>\n<p><img decoding=\"async\" class=\"size-medium wp-image-21578 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Harmonics_SC24-143x300.jpg\" alt=\"\" width=\"143\" height=\"300\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Harmonics_SC24-143x300.jpg 143w, https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Harmonics_SC24-337x705.jpg 337w, https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/Harmonics_SC24.jpg 339w\" sizes=\"(max-width: 143px) 100vw, 143px\" \/><\/p>\n<p><span style=\"font-weight: 400;\">Algorithm enhancements include:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Crest Factor calculations with continuous log sweeps in addition to stepped sine sweeps<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Maximum and minimum curve outputs from Crest Factor\u2019s high pass filter for looking at Impulsive Distortion Peak. With the high-pass filter disabled, it can also be used for looking at cone displacement max. and min. versus frequency.\u00a0<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Extended bandwidth for Log Sweep distortion measurements up to the Nyquist frequency instead of the<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u00a0maximum stimulus frequency for users working with high sampling rates.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">User-configurable fade-in and fade-out duration for the Farina Log Sweep, to minimize ringing at the beginning or end of the sweep<\/span><\/li>\n<\/ul>\n<p><b>TCP\/IP and Automation Enhancements<\/b><\/p>\n<p><span style=\"font-weight: 400;\">New TCP\/IP commands to simplify control of automated and headless test systems include:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Hardware Refresh to trigger detection of newly connected devices through the TCP\/IP interface.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\"><img decoding=\"async\" class=\"size-medium wp-image-21572 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/WAV_start_stop-300x271.jpg\" alt=\"\" width=\"300\" height=\"271\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/WAV_start_stop-300x271.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/WAV_start_stop-705x636.jpg 705w, https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/WAV_start_stop.jpg 707w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/>Support for new calibration features including updating calibrated device assignments, and reading all TEDS devices without opening the Calibration Table.<\/span><\/li>\n<\/ul>\n<p><b>Additional Stimulus Flexibility<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Stimulus options now include:\u00a0<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">WAV file start and stop times defined directly in the Stimulus editor, making it easy to play only the desired portion of a recording.\u00a0<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">A specified seed value for white and pink noise generation, ensuring the same noise signal is used for every measurement.<\/span><\/li>\n<\/ul>\n<p>Download SoundCheck 24 New Features PDF \u00a0<a href=\"https:\/\/www.listeninc.com\/wp\/media\/2026\/07\/SC24_New-Features.pdf\"><img decoding=\"async\" class=\"alignnone wp-image-2556 size-full\" src=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg\" alt=\"\" width=\"50\" height=\"50\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg 50w, https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon-36x36.jpg 36w\" sizes=\"(max-width: 50px) 100vw, 50px\" \/><\/a><\/p>\n<\/div><\/section><\/p><\/div><\/p>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-4km6xg-b4faa336545fafae1c1fb4a8d673f902\">\n.flex_column.av-4km6xg-b4faa336545fafae1c1fb4a8d673f902{\nborder-radius:0px 0px 0px 0px;\npadding:0px 0px 0px 0px;\n}\n<\/style>\n<div  class='flex_column av-4km6xg-b4faa336545fafae1c1fb4a8d673f902 av_one_full  avia-builder-el-13  el_after_av_one_full  el_before_av_one_full  first flex_column_div av-zero-column-padding  column-top-margin'     ><section  id=\"version_20\"  class='av_textblock_section av-mb7zdith-0165a0adacae78f6f9bbfe8f334bead1 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>SoundCheck New Features: Version 23 (2025)<\/h3>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-mb7zftt8-4bad61b2e56b1412fe516d16b822e6a2 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><iframe loading=\"lazy\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/Y7OUdZ6FH3Y\" width=\"400\" height=\"225\" frameborder=\"0\" align=\"right\" allowfullscreen=\"allowfullscreen\"><\/iframe><strong><em>SoundCheck 23 breaks new ground in perceptual audio analysis with real-time tonal masking curves for detailed insight into audibility. It also offers a new multi-channel oscilloscope, a new time\/ frequency cursor for recorded Stweep waveforms, and support for AudioConnect 8&#215;8, Listen\u2019s newest multi-channel interface. Functionality improvements include enhanced display performance and sequence editor upgrades to accelerate sequence development.<\/em><\/strong><\/p>\n<\/div><\/section><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-2a9q90-e28b1f3def93686ed6da886191d60dcb\">\n#top .hr.hr-invisible.av-2a9q90-e28b1f3def93686ed6da886191d60dcb{\nheight:25px;\n}\n<\/style>\n<div  class='hr av-2a9q90-e28b1f3def93686ed6da886191d60dcb hr-invisible  avia-builder-el-16  el_after_av_textblock  el_before_av_textblock '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n<section  class='av_textblock_section av-mb811z7k-def25f2580a46a35c153251065c39006 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><strong><img decoding=\"async\" class=\"alignright wp-image-17591\" src=\"https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Masking-Curves-Arrow.png\" alt=\"\" width=\"338\" height=\"165\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Masking-Curves-Arrow.png 1364w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Masking-Curves-Arrow-300x146.png 300w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Masking-Curves-Arrow-1300x634.png 1300w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Masking-Curves-Arrow-768x374.png 768w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Masking-Curves-Arrow-705x344.png 705w\" sizes=\"(max-width: 338px) 100vw, 338px\" \/>Masking Curves <\/strong>SoundCheck is the first audio measurement software to offer real-time tonal masking and threshold-of-hearing curves in a spectrum analyzer. This demonstrates where a dominant tone is audibly masking other frequencies and noise to provide a clear visual correlation of measurements to audibility. The masking and threshold-of-hearing curves can be superimposed on any sound level spectrum measurement. They automatically track the dominant tone, making any harmonics above the masking and threshold-of-hearing curves clearly visible. This simplifies diagnosis of the mechanisms causing the distortion. In R&amp;D, this helps balance component quality or size with cost, avoiding audible distortion while not over-designing to reduce inaudible distortion. In production applications, this feature helps identify the root cause of audible distortion if the loudspeaker fails a perceptual Rub &amp; Buzz (ePRB) test on the production line.<\/p>\n<p><strong><img decoding=\"async\" class=\"alignright wp-image-17593\" src=\"https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Stimulus-Frequency-Counter-1.png\" alt=\"\" width=\"362\" height=\"150\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Stimulus-Frequency-Counter-1.png 2388w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Stimulus-Frequency-Counter-1-300x124.png 300w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Stimulus-Frequency-Counter-1-1300x539.png 1300w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Stimulus-Frequency-Counter-1-768x318.png 768w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Stimulus-Frequency-Counter-1-1536x637.png 1536w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Stimulus-Frequency-Counter-1-2048x849.png 2048w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Stimulus-Frequency-Counter-1-1500x622.png 1500w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Stimulus-Frequency-Counter-1-705x292.png 705w\" sizes=\"(max-width: 362px) 100vw, 362px\" \/>Stimulus Frequency Cursor <\/strong><span style=\"font-weight: 400;\">The new stimulus frequency cursor in stepped-sine measurement waveform graphs lets you quickly identify the frequency at which an event occurs. Simply position the cursor over the relevant event in the waveform graph for a clear on-screen display of the stimulus frequency. This can be used with the Enhanced Loose Particles Algorithm to easily identify the frequencies at which transients occur.<\/span><\/p>\n<p><b><img decoding=\"async\" class=\"alignright size-medium wp-image-17596\" src=\"https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Frequency-Counter-300x159.png\" alt=\"\" width=\"300\" height=\"159\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Frequency-Counter-300x159.png 300w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Frequency-Counter-1300x691.png 1300w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Frequency-Counter-768x408.png 768w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Frequency-Counter-1536x816.png 1536w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Frequency-Counter-2048x1089.png 2048w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Frequency-Counter-1500x797.png 1500w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Frequency-Counter-710x375.png 710w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Frequency-Counter-705x375.png 705w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/b><strong>Frequency Counter<\/strong> <span style=\"font-weight: 400;\">SoundCheck\u2019s frequency counter can now convert frequency in Hertz to alternative units such as RPM. This enables sound and vibration characteristics to be plotted in relation to parameters such as fan speed, or allows road noise to be mapped to the speed of the car.<\/span><\/p>\n<p><b><img decoding=\"async\" class=\"alignright size-medium wp-image-17598\" src=\"https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Oscope-2ch-sine-300x132.png\" alt=\"\" width=\"300\" height=\"132\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Oscope-2ch-sine-300x132.png 300w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Oscope-2ch-sine-768x337.png 768w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Oscope-2ch-sine-705x309.png 705w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Oscope-2ch-sine.png 1211w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/b><b>Multichannel Oscilloscope<\/b> <span style=\"font-weight: 400;\">SoundCheck\u2019s oscilloscope is now integrated into the multi-instrument. Like the FFT and RTA, it features full multichannel capability, displaying multiple<\/span>\u00a0live waveforms on the same graph. A shared trigger between oscilloscope channels as well as the RTA and FFT enables synchronized display of all three results simultaneously. This is useful for examining measured parameters in both the time and frequency domains, e.g. interchannel time delays and crosstalk.<\/p>\n<p><strong><a href=\"https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/SC23-New-Features-Enhanced-Display-Performance.bmp\"><img decoding=\"async\" class=\"wp-image-17600 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/SC23-New-Features-Enhanced-Display-Performance.bmp\" alt=\"\" width=\"300\" height=\"175\" \/><\/a>Enhanced Display Performance <\/strong><span style=\"font-weight: 400;\">SoundCheck\u2019s Displays are improved with increased speed and stability for large data sets, for example when displaying multiple graphs or multiple curves on a graph. Additional functionality includes the ability to zoom using a mouse scroll-wheel and panning using either mouse or keyboard controls.<\/span><\/p>\n<p><strong>Sequence Editor Improvements <\/strong>SoundCheck 23 offers easier and faster sequence development with enhancements including:<\/p>\n<ul>\n<li><span style=\"font-weight: 400;\">Copy and paste steps: A timesaver when creating many similar steps in a sequence.<\/span><\/li>\n<li><span style=\"font-weight: 400;\">Enable and disable steps with a simple mouse click or shortcut key: Specific parts of a sequence can now be tested without the need to run the entire sequence, and steps can be toggled on and off for troubleshooting. <\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Downstream Updating: If any curve, value, or result names change when editing a step, those changed names are now automatically updated in any sequential steps. This makes editing sequences considerably faster and ensures that workflows are not accidentally interrupted by renaming data in a Step Editor.<\/span><\/li>\n<\/ul>\n<p><strong><img decoding=\"async\" class=\"wp-image-17602 size-medium alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Loudness-108x300.png\" alt=\"\" width=\"108\" height=\"300\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Loudness-108x300.png 108w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Loudness-469x1300.png 469w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Loudness-555x1536.png 555w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Loudness-542x1500.png 542w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Loudness-255x705.png 255w, https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/Loudness.png 700w\" sizes=\"(max-width: 108px) 100vw, 108px\" \/>Loudness<\/strong> <span style=\"font-weight: 400;\">ISO 532-3 loudness measurements are now included in optional module 2031 Loudness Standards. This enables calculation of perceived loudness in phons or sones over time for complex and sine-based waveforms such as music and noise according to this new international standard.<\/span><\/p>\n<p><strong>Expanded Online Statistics<\/strong> <span style=\"font-weight: 400;\">Statistics may now be run across multiple signal paths, for example multiple microphones in an array.<\/span><\/p>\n<p><strong>Metadata in Autosave<\/strong> <span style=\"font-weight: 400;\">Metadata capability is now extended to autosave formats including text and Excel.<\/span><\/p>\n<p><b>MDT-4000 Ethernet support<\/b> <span style=\"font-weight: 400;\">A new custom step permits control of the MDT-4000 turntable via ethernet. This is useful for applications where the turntable is not located close to the SoundCheck computer, for example in an anechoic chamber.<\/span><\/p>\n<p><strong>AudioConnect 8&#215;8 Support <\/strong>SoundCheck 23 includes full support for AudioConnect 8&#215;8, Listen\u2019s newest multi-channel audio interface. This high resolution interface offers 8 analog input and output channels plus 2 S\/PDIF channels for digital signals. All input channels provide microphone power (constant voltage and constant current) and TEDS calibration support. Up to four AudioConnect 8&#215;8\u2019s can be connected for up to 32 synchronized analog input and output channels. AudioConnect 8&#215;8 is fully configured via the software, making setup fast and easy, and allowing advanced features such as auto-ranging for maximum dynamic range measurements.<\/p>\n<p><strong><img decoding=\"async\" class=\"alignright wp-image-17289 size-medium\" src=\"https:\/\/www.listeninc.com\/wp\/media\/2025\/04\/AC_8X8_front_trans-1-scaled-e1745944947972-300x70.png\" alt=\"\" width=\"300\" height=\"70\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2025\/04\/AC_8X8_front_trans-1-scaled-e1745944947972-300x70.png 300w, https:\/\/www.listeninc.com\/wp\/media\/2025\/04\/AC_8X8_front_trans-1-scaled-e1745944947972-1300x303.png 1300w, https:\/\/www.listeninc.com\/wp\/media\/2025\/04\/AC_8X8_front_trans-1-scaled-e1745944947972-768x179.png 768w, https:\/\/www.listeninc.com\/wp\/media\/2025\/04\/AC_8X8_front_trans-1-scaled-e1745944947972-1536x358.png 1536w, https:\/\/www.listeninc.com\/wp\/media\/2025\/04\/AC_8X8_front_trans-1-scaled-e1745944947972-2048x477.png 2048w, https:\/\/www.listeninc.com\/wp\/media\/2025\/04\/AC_8X8_front_trans-1-scaled-e1745944947972-1500x350.png 1500w, https:\/\/www.listeninc.com\/wp\/media\/2025\/04\/AC_8X8_front_trans-1-scaled-e1745944947972-705x164.png 705w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/strong><\/p>\n<p><b>\u00a0<\/b><\/p>\n<p>Download SoundCheck 23 New Features PDF <a href=\"https:\/\/www.listeninc.com\/wp\/media\/2025\/05\/SC23_New-Features.pdf\"><img decoding=\"async\" class=\"alignnone wp-image-2556 size-full\" src=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg\" alt=\"download_pdf_icon\" width=\"50\" height=\"50\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg 50w, https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon-36x36.jpg 36w\" sizes=\"(max-width: 50px) 100vw, 50px\" \/><\/a><\/p>\n<\/div><\/section><\/p><\/div>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-awps7o-eef6e4fdba311cce34bfb14c6b0e59e9\">\n.flex_column.av-awps7o-eef6e4fdba311cce34bfb14c6b0e59e9{\nborder-radius:0px 0px 0px 0px;\npadding:0px 0px 0px 0px;\n}\n<\/style>\n<div  class='flex_column av-awps7o-eef6e4fdba311cce34bfb14c6b0e59e9 av_one_full  avia-builder-el-18  el_after_av_one_full  el_before_av_one_full  first flex_column_div av-zero-column-padding  column-top-margin'     ><section  id=\"version_20\"  class='av_textblock_section av-l0l5jkn2-a6f9fe73b660d9040d8d2d651a166b3f '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>SoundCheck New Features: Version 22 (2024)<\/h3>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-l48k3y0r-67aad33b08241c198059d31b3ec1df76 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><iframe loading=\"lazy\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/KNaQMRLUT0U\" width=\"400\" height=\"225\" frameborder=\"0\" align=\"right\" allowfullscreen=\"allowfullscreen\"><\/iframe> <em><strong>SoundCheck 22 leads the way in production line testing with Python integration, sequence versioning, more powerful metadata options and enhanced statistics functionality. R&amp;D users also see a capability-boost with crest factor analysis, new post-processing functionality and upgraded virtual instruments.<\/strong><\/em><\/p>\n<\/div><\/section><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-lt3e8bgm-badb3169f0129155294323c878101cad\">\n#top .hr.hr-invisible.av-lt3e8bgm-badb3169f0129155294323c878101cad{\nheight:25px;\n}\n<\/style>\n<div  class='hr av-lt3e8bgm-badb3169f0129155294323c878101cad hr-invisible  avia-builder-el-21  el_after_av_textblock  el_before_av_textblock '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n<section  class='av_textblock_section av-l0l5opfj-a89ca092c50a4568e67a08344deee034 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><strong><img decoding=\"async\" class=\"alignright wp-image-15334\" src=\"..\/media\/2024\/05\/Python_custom_step.png\" alt=\"\" width=\"350\" height=\"178\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/Python_custom_step.png 751w, https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/Python_custom_step-300x153.png 300w, https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/Python_custom_step-705x360.png 705w\" sizes=\"(max-width: 350px) 100vw, 350px\" \/>Python Custom Step (optional module #2042)<\/strong> The new Python custom step module (part #2042) enables users to call custom Python functions from a SoundCheck sequence. This makes it easy to pass data and variables between SoundCheck and other devices or programs. Applications include sending custom commands to put a device into diagnostic mode or playing a test signal from a device. It also enables communication with custom databases, and passing directional measurements to programs such as VACS and EASE for balloon analysis. Users can also call MATLAB functions via Python for automated MATLAB analysis of SoundCheck measurements. The Python custom step module avoids requiring LabVIEW to integrate with other programs, simplifying programming and maintenance.<\/p>\n<p><strong>Crest Factor Analysis<\/strong> <img decoding=\"async\" class=\"alignright wp-image-15336\" src=\"..\/media\/2024\/05\/sequence_versioning.png\" alt=\"\" width=\"250\" height=\"179\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/sequence_versioning.png 697w, https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/sequence_versioning-300x214.png 300w, https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/sequence_versioning-260x185.png 260w\" sizes=\"(max-width: 250px) 100vw, 250px\" \/>Crest factor analysis is a technique that measures peak-to-RMS ratio to evaluate impulsive distortion and analyze the dynamic range of real signals. It complements SoundCheck\u2019s unique enhanced Loose Particle algorithm for transient distortion measurement and enables comparison of the two methods using the same measured data. Crest factor can be calculated and displayed via a multimeter on the input signal path as well as in the analysis step.<\/p>\n<p><strong>Sequence Versioning<\/strong> Sequence versioning makes it easy to track changes made to a sequence to ensure that colleagues and contract manufacturers are using the correct version. Comment fields make it easy to document changes, and the sequence history view provides a log of historical changes. Archiving functionality allows the sequence to be backed up while it is being developed, so changes can easily be rolled back while retaining the versioning information. <strong><strong data-wp-editing=\"1\"><img decoding=\"async\" class=\"alignright wp-image-15338\" src=\"..\/media\/2024\/05\/Statistics_SC22.png\" alt=\"\" width=\"300\" height=\"281\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/Statistics_SC22.png 816w, https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/Statistics_SC22-300x281.png 300w, https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/Statistics_SC22-768x718.png 768w, https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/Statistics_SC22-705x659.png 705w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/strong><\/strong><\/p>\n<p><strong>New Statistics Module<\/strong> SoundCheck\u2019s statistics module is completely overhauled to make it more powerful and intuitive. A new layout makes data selection easier, and curves, values, and results can now simply be dragged and dropped from the memory list into the statistics editor. A new \u2018Reset Statistics\u2019 step allows statistics to be reset during a sequence. This is useful when applying statistical analysis to data from a sequence loop or a fixed number of measurements, as the statistics data and sample count can be automatically cleared, ready for the next measurement once the desired settings have been reached. Enhanced searching, including meta-data, makes it easy to select groups of curves from the memory list, and it is now even possible to specify a frequency range within which to run statistics.<\/p>\n<p><strong>Powerful New Post-Processing Tools<\/strong> New powerful post-processing tools expand SoundCheck\u2019s calculation capabilities and simplify complex applications. These include:<\/p>\n<p><img decoding=\"async\" class=\"alignright wp-image-15342\" src=\"..\/media\/2024\/05\/Post-processing_ignore_units.png\" alt=\"\" width=\"400\" height=\"189\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/Post-processing_ignore_units.png 777w, https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/Post-processing_ignore_units-300x142.png 300w, https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/Post-processing_ignore_units-768x364.png 768w, https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/Post-processing_ignore_units-705x334.png 705w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/p>\n<ul>\n<li>Logarithm and Exponent calculation using base 2, 10, or custom values, in addition to the existing base e.<\/li>\n<li>Leq (equivalent continuous sound level) versus Time option for use in noise monitoring, communications applications, and many standards.<\/li>\n<li>A new &#8216;Intersection Modes&#8217; option for greater specificity in the choice of finding intersection points.<\/li>\n<li>An option to ignore units in arithmetic and constant post-processing. This facilitates simple mathematical calculations, for example, quickly subtracting a fixed number of dB to correct sound level from the near field to the far field.<\/li>\n<li>A &#8216;Cosine Taper&#8217; custom window in post-processing FFT which allows leading and trailing taper widths to be customized. This is useful for time-windowed measurements.<\/li>\n<\/ul>\n<p><strong>Metadata Enhancements<\/strong> Additional metadata functionality makes this feature even more powerful. New system metadata options include Sound-Check version, sequence version, start and save date and time. Metadata can now be applied either during the run of a sequence or appended at the end, and the metadata may be applied to either a single measurement or a batch of measurements. This allows the addition of specific test condition information to an entire batch of measurements or allows a user to input information regarding the DUT at the end of the test, for example, a subjective opinion on sound quality. Metadata can even be loaded from a file, saving time and eliminating errors. It is easy to identify results by metadata as this can now be searched in the memory list, and the metadata of any selected curve can be displayed simply by selecting it in a display window.<\/p>\n<p><strong>Upgraded Signal Generator and Multimeter<img decoding=\"async\" class=\"alignright wp-image-15346\" src=\"..\/media\/2024\/05\/Strip-Chart-Accelerometer-1.png\" alt=\"\" width=\"400\" height=\"213\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/Strip-Chart-Accelerometer-1.png 992w, https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/Strip-Chart-Accelerometer-1-300x160.png 300w, https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/Strip-Chart-Accelerometer-1-768x410.png 768w, https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/Strip-Chart-Accelerometer-1-705x376.png 705w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/strong> The signal generator and multimeter offer added support for accelerometers and shakers in applications where haptic, or both acoustic and haptic, measurements need to be made. These include fan noise measurements, vibrating car seats, and MEMS microphone\/accelerometer combinations. Acceleration units can now be calibrated in g as well as m\/s\u00b2, and offer the option to integrate acceleration to velocity in the multimeter. The signal generator now allows maximum and minimum output levels and frequencies to be set. This limits the range of the signal path to help prevent accidental equipment damage. These levels are retained when the configuration is saved or used in a sequence, but levels can still be manually adjusted within these ranges. Waveforms can now be played back at their original recorded level with no gain applied. This is useful for listening tests.<\/p>\n<p><strong>Multi-Instrument Enhancements<\/strong><strong><img decoding=\"async\" class=\"alignright wp-image-15344\" src=\"..\/media\/2024\/05\/multi-instrument_enhancements.png\" alt=\"\" width=\"400\" height=\"301\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/multi-instrument_enhancements.png 893w, https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/multi-instrument_enhancements-300x226.png 300w, https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/multi-instrument_enhancements-768x579.png 768w, https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/multi-instrument_enhancements-705x531.png 705w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/strong> The multi-instrument, which includes both an RTA and FFT analyzer, now includes additional display and calculation options. A single multi-instrument can have multiple simultaneous display windows. These are now detached from the control panel, and can be re-sized and re-positioned for unlimited desktop layout flexibility. Multi-instrument windows can now also be used in a sequence step to offer a clear readout of results while the sequence is running. Real time calculation can be implemented on a combination of live and stored (active and static) curves simultaneously which enables clear display of the difference between live results and a reference curve. Finally, a new dB addition option expands its calculation capabilities.<\/p>\n<p><strong>Apple Silicon Support<\/strong> <img decoding=\"async\" class=\"alignright size-thumbnail wp-image-15340\" src=\"..\/media\/2024\/05\/M-Series_Logo-80x80.png\" alt=\"\" width=\"80\" height=\"80\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/M-Series_Logo-80x80.png 80w, https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/M-Series_Logo-36x36.png 36w, https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/M-Series_Logo-180x180.png 180w\" sizes=\"(max-width: 80px) 100vw, 80px\" \/>SoundCheck displays significant speed and performance benefits on Apple computers with M processors. Step and sequence editing, in particular, are considerably faster.<\/p>\n<p>Download SoundCheck 22 New Features PDF <a href=\"https:\/\/www.listeninc.com\/wp\/media\/2024\/05\/SC22_New_Features.pdf\"><img decoding=\"async\" class=\"alignnone wp-image-2556 size-full\" src=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg\" alt=\"download_pdf_icon\" width=\"50\" height=\"50\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg 50w, https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon-36x36.jpg 36w\" sizes=\"(max-width: 50px) 100vw, 50px\" \/><\/a><\/p>\n<\/div><\/section><\/p><\/div>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-z4uac-dbf647fa659c6250069fa8ebe0f5e2fc\">\n.flex_column.av-z4uac-dbf647fa659c6250069fa8ebe0f5e2fc{\nborder-radius:0px 0px 0px 0px;\npadding:0px 0px 0px 0px;\n}\n<\/style>\n<div  class='flex_column av-z4uac-dbf647fa659c6250069fa8ebe0f5e2fc av_one_full  avia-builder-el-23  el_after_av_one_full  el_before_av_hr  first flex_column_div av-zero-column-padding  column-top-margin'     ><section  id=\"version_20\"  class='av_textblock_section av-7zlpd0-43d8e026046b76ac40966c77f87af15b '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>SoundCheck New Features: Version 21 (2023)<\/h3>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-61u4p0-ae0756ea75f185cefa199d8572cf4273 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><iframe loading=\"lazy\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/a6gkJ7eSrI8\" width=\"400\" height=\"225\" frameborder=\"0\" align=\"right\" allowfullscreen=\"allowfullscreen\"><\/iframe> <em><strong>SoundCheck 21 introduces our new enhanced Loose Particles algorithm for transient distortion measurement in a wide range of devices. It also offers increased multichannel measurement capability with the new multichannel FFT analyzer. Other enhancements such as the ability to save metadata, sequence protection and AudioConnect 2 control round out the increased functionality of this year\u2019s update.<\/strong><\/em><\/p>\n<\/div><\/section><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-3t8w90-16dafa0da514de30c0981d20b2c49b6b\">\n#top .hr.hr-invisible.av-3t8w90-16dafa0da514de30c0981d20b2c49b6b{\nheight:25px;\n}\n<\/style>\n<div  class='hr av-3t8w90-16dafa0da514de30c0981d20b2c49b6b hr-invisible  avia-builder-el-26  el_after_av_textblock  el_before_av_textblock '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n<section  class='av_textblock_section av-22439g-d570401af64b425afcbfd672a60e5f19 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><strong><a href=\"https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/ePL.png\"><img decoding=\"async\" class=\"alignright wp-image-11714\" src=\"https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/ePL-246x300.png\" alt=\"\" width=\"190\" height=\"231\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/ePL-246x300.png 246w, https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/ePL-1067x1300.png 1067w, https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/ePL-768x935.png 768w, https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/ePL-1261x1536.png 1261w, https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/ePL-1232x1500.png 1232w, https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/ePL-579x705.png 579w, https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/ePL.png 1638w\" sizes=\"(max-width: 190px) 100vw, 190px\" \/><\/a>Enhanced Loose Particle Detection<\/strong><br \/>\nA new enhanced Loose Particle detection algorithm for measurement of transient distortion is more accurate and offers improved correlation to subjective listening. The new algorithm builds on the success of Listen\u2019s original 2005 algorithm, the first method developed for detecting random transient production line defects such as rattling parts, loose particles and other foreign material in the voice coil gap. Based on the same time-envelope analysis, it introduces advanced algorithmic techniques to better highlight the loose particle defects while minimizing other artifacts. Advanced filtering methods enable the stimulus to be removed from the response so only the defects can be heard. This makes it easy to set limits in line with subjective tests. In addition to identifying distortion caused by foreign material in the voice coil gap of a speaker, it is also valuable for detecting rattling buttons on smart devices and Bluetooth speakers, and identifying buzz, squeak and rattle in automotive audio applications.<\/p>\n<p><b><a href=\"https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/Mutli-Spectrum-Analyzer.png\"><img decoding=\"async\" class=\"alignright size-medium wp-image-11720\" src=\"https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/Mutli-Spectrum-Analyzer-300x146.png\" alt=\"\" width=\"300\" height=\"146\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/Mutli-Spectrum-Analyzer-300x146.png 300w, https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/Mutli-Spectrum-Analyzer-1300x634.png 1300w, https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/Mutli-Spectrum-Analyzer-768x374.png 768w, https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/Mutli-Spectrum-Analyzer-1536x749.png 1536w, https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/Mutli-Spectrum-Analyzer-2048x998.png 2048w, https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/Mutli-Spectrum-Analyzer-1500x731.png 1500w, https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/Mutli-Spectrum-Analyzer-705x344.png 705w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a>Multichannel Spectrum Analyzer<br \/>\n<\/b>A new multi-channel FFT analyzer replaces SoundCheck\u2019s original single channel spectrum analyzer. This high resolution constant bandwidth linear filter analyzer enables any number of live FFT spectra to be simultaneously viewed in real time on the same graph. It offers many\u00a0 options including standard and custom <b><\/b>windows and various weighting options. Averaging times and resolution are continuously variable and can be user-specified. Average, maximum and minimum levels can be identified, and overload and real time indicators highlight any problematic signals. Channel subtraction, maximum, minimum and power average can be calculated and displayed in real time. This saves screen space and allows direct comparisons when making multiple FFT measurements. Live FFT curves are displayed in the memory list and can be dragged and dropped into any graph for easy comparison to limits and reference curves. SoundCheck\u2019s multichannel FFT and RTA can be viewed simultaneously, either side by side or superimposed on one another. This enables both high resolution spectra and constant percentage bandwidth resolution (eg. 1\/12th Octave) measurements to be viewed at the same time. Typical applications include analyzing broadband speech signals while accurately identifying single frequency interference tones, or analyzing intermodulation distortion in the presence of speech or music.<a href=\"https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/Metadata.png\"><img decoding=\"async\" class=\"alignright wp-image-11718\" src=\"https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/Metadata-206x300.png\" alt=\"\" width=\"160\" height=\"233\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/Metadata-206x300.png 206w, https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/Metadata-485x705.png 485w, https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/Metadata.png 636w\" sizes=\"(max-width: 160px) 100vw, 160px\" \/><\/a><\/p>\n<p><strong><b>Metadata for Simplified Data Collection and Recall<\/b><\/strong><br \/>\nSoundCheck\u2019s new Metadata feature simplifies data collection and documentation. Curves, values, results and waveforms can now be saved to a single TDMS file, along with all test parameters acquired during the sequence\u00a0run such as test conditions, test sequence used, operator, serial number, microphone position, data entered via a message step and more. Both system fields (e.g. sequence name, operator, SoundCheck serial number) and user-defined fields can be stored. This data can be viewed or recalled in SoundCheck, as well as by certain other applications such as excel. The TDMS format used to save the data is a fast binary format, minimizing read and write times when a sequence is running. This feature has many uses in both R&amp;D and production applications.<\/p>\n<p><strong><b><a href=\"https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/Sequence-Protection.png\"><img decoding=\"async\" class=\"alignright wp-image-11722\" src=\"https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/Sequence-Protection-175x300.png\" alt=\"\" width=\"130\" height=\"223\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/Sequence-Protection-175x300.png 175w, https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/Sequence-Protection-411x705.png 411w, https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/Sequence-Protection.png 558w\" sizes=\"(max-width: 130px) 100vw, 130px\" \/><\/a>Sequence Protection<\/b><\/strong><br \/>\nSequence protection guards your intellectual property and adds an additional level of assurance that your tests are run as-intended by your production facility or contract manufacturer. Any test sequence can now be locked and password protected before distribution. Once in a locked state, it can be run, but sequence steps and limits cannot be edited without the password. Furthermore the sequence steps cannot even be viewed, protecting the intellectual property in your sequences. Sequences can also be configured to only run on a particular SoundCheck system, or block of systems. This further protects against unauthorized use and helps ensure the end-to-end integrity of your tests when working with contract manufacturers, guaranteeing that your products are tested exactly as you planned.<\/p>\n<p><a href=\"https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/ac2-front-right.jpg\"><img decoding=\"async\" class=\"alignright wp-image-11665\" src=\"https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/ac2-front-right-300x108.jpg\" alt=\"\" width=\"330\" height=\"118\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/ac2-front-right-300x108.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/ac2-front-right-768x275.jpg 768w, https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/ac2-front-right-705x253.jpg 705w, https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/ac2-front-right.jpg 1200w\" sizes=\"(max-width: 330px) 100vw, 330px\" \/><\/a><\/p>\n<p><strong><b>AudioConnect 2 Support<\/b><\/strong><br \/>\nSoundCheck 21 supports AudioConnect 2<sup>TM<\/sup>, Listen\u2019s new compact and high resolution (up to 192 kHz) dual-channel audio interface. AudioConnect 2 is designed for measurements anywhere from the production line to out in the field. With the option to power it via a laptop USB-C port, it is compact, portable, and easy to use. Set-up and configuration is extremely simple and fast with full plug-and-play functionality and TEDS support for automatic identification, configuration and calibration of microphones and accelerometers. AudioConnect 2 has no front panel controls; it is exclusively configured via the SoundCheck software. This provides an added level of test integrity by ensuring that settings cannot be inadvertently adjusted outside of your test configuration.<\/p>\n<p><a href=\"https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/SC21_New-Features.pdf\">Download SoundCheck 21 New Features PDF<\/a> <a href=\"https:\/\/www.listeninc.com\/wp\/media\/2023\/02\/SC21_New-Features.pdf\"><img decoding=\"async\" class=\"alignnone wp-image-2556 size-full\" src=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg\" alt=\"download_pdf_icon\" width=\"50\" height=\"50\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg 50w, https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon-36x36.jpg 36w\" sizes=\"(max-width: 50px) 100vw, 50px\" \/><\/a><\/p>\n<\/div><\/section><\/p><\/div>\n<div  class='hr av-lt3e98q3-82b10691064494998817efe0ef2d81a6 hr-default  avia-builder-el-28  el_after_av_one_full  el_before_av_one_full '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div>\n<div  class='flex_column av-15c0idw-17f3f734c53e7a30209e533abf191ae2 av_one_full  avia-builder-el-29  el_after_av_hr  el_before_av_one_full  first flex_column_div  '     ><section  id=\"version_20\"  class='av_textblock_section av-l0l5jkn2-26-051b6a85e241729f1888d97e855aba4c '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>SoundCheck New Features: Version 20 (2022)<\/h3>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-l48k3y0r-25-4409f3531b849e005d65390d6ef05e27 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><iframe loading=\"lazy\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/rqjYnbyPDxI\" width=\"400\" height=\"225\" frameborder=\"0\" align=\"right\" allowfullscreen=\"allowfullscreen\"><\/iframe><em><strong>SoundCheck 20 introduces our state-of-the-art perceptual distortion algorithm for end-of-line testing &#8211; Enhanced Perceptual Rub &amp; Buzz. It also includes a host of new features for multichannel and communications testing, increasing its capabilities for audio measurement of smart speakers, infotainment systems, headphones and hearables, and other voice-activated and multichannel devices.<\/strong><\/em><\/p>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-l0l5opfj-24-cffe44a2d23f3029969e4f85752cab50 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><strong>Enhanced Perceptual Rub &amp; Buzz<\/strong><br \/>\n<a href=\"https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/ePRB_Algorithm_Comparison_outline.png\"><img decoding=\"async\" class=\"alignright size-medium wp-image-9608\" src=\"https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/ePRB_Algorithm_Comparison_outline-300x138.png\" alt=\"\" width=\"300\" height=\"138\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/ePRB_Algorithm_Comparison_outline-300x138.png 300w, https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/ePRB_Algorithm_Comparison_outline-768x353.png 768w, https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/ePRB_Algorithm_Comparison_outline-705x324.png 705w, https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/ePRB_Algorithm_Comparison_outline.png 1107w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a>Listen\u2019s new Perceptual Rub &amp; Buzz algorithm is a reliable and repeatable method of detecting audible Rub &amp; Buzz faults on the production line. This offers manufactures the option to increase yield by rejecting only those devices with audible distortion defects. Based on the sound psychoacoustic principles used in Listen\u2019s industry-standard 2011 Perceptual Rub &amp; Buzz algorithm, the new refinements improve listener correlation and demonstrate significantly better noise rejection to offer unrivaled repeatability. This makes limit setting easier and increases reliability, especially in production environments. The algorithm measures perceptual Rub &amp; Buzz at the same time as all other end-of-line measurements with a single stepped sine wave stimulus, enabling this valuable analysis to be added to production line tests with no extension in test time.<\/p>\n<p><strong id=\"mrta\">New Multichannel RTA functionality<\/strong><\/p>\n<p><a href=\"https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/Multi-RTA-Headph-Seal-W-target.png\"><img decoding=\"async\" class=\"alignright size-medium wp-image-9604\" src=\"https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/Multi-RTA-Headph-Seal-W-target-300x146.png\" alt=\"\" width=\"300\" height=\"146\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/Multi-RTA-Headph-Seal-W-target-300x146.png 300w, https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/Multi-RTA-Headph-Seal-W-target-768x374.png 768w, https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/Multi-RTA-Headph-Seal-W-target-705x344.png 705w, https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/Multi-RTA-Headph-Seal-W-target.png 1085w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a>The multichannel Real Time Analyzer now includes expanded functionality for real time observation of audio signals. It displays multiple channels simultaneously, and offers real time calculation and display of channel addition, subtraction, maximum, minimum and power average. Applications for this new feature include real-time observation of active noise cancellation, automotive industry standard 6-microphone array infotainment measurements, validating headphone seal on a test head prior to measurement by comparing left and right earphone response, and more. Paired with the AmpConnect 621 multichannel audio interface, it offers unmatched functionality for multichannel measurements on a wide array of devices, especially those featuring dynamic signal processing. RTA curves are now seamlessly integrated with SoundCheck\u2019s standard graphs. Live curves from the RTA are displayed in the memory list and can be dragged and dropped into any graph for easy comparison to limits and reference curves. This is useful for quick comparisons to reference standards or golden units, tuning automotive infotainment systems, and more.<\/p>\n<p><strong>Updated Signal Generator<a href=\"https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/Sig-Gen-SC20-WAV-Play-Start-Stop.png\"><img decoding=\"async\" class=\"alignright wp-image-9610\" src=\"https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/Sig-Gen-SC20-WAV-Play-Start-Stop-165x300.png\" alt=\"\" width=\"120\" height=\"218\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/Sig-Gen-SC20-WAV-Play-Start-Stop-165x300.png 165w, https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/Sig-Gen-SC20-WAV-Play-Start-Stop.png 291w\" sizes=\"(max-width: 120px) 100vw, 120px\" \/><\/a><\/strong><br \/>\nA complete overhaul of the signal generator brings additional functionality and simplified operation, particularly when using wav files. In addition to standard audio stimuli (sine, white noise, pink noise) with user-selected sampling rates and resolution, it can play any wav file, any memory list file, and any complex waveform created by the stimulus editor. The level can be referenced to Peak, dB or RMS. The signal can be equalized in real time, and custom EQ curves applied, which is useful when using a non-flat source such as a mouth simulator. A specific portion of a waveform can be selected to play, either by selecting a start and stop time in seconds, or by examining the waveform. Outputs from 2 or more signal generators can be mixed on the same channel. Waveforms from multiple signal generators can be synchronized, or a delay added for non-coherent playback, for example when generating background noise. Signals may be played for a fixed duration, a fixed number of times, or in a continuous loop. Slider control, in addition to numerical entry, simplifies use.<\/p>\n<p><strong>POLQA<\/strong><br \/>\n<a href=\"https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/POLQA-Step-and-Data.png\"><img decoding=\"async\" class=\"alignright wp-image-9612\" src=\"https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/POLQA-Step-and-Data-203x300.png\" alt=\"\" width=\"180\" height=\"267\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/POLQA-Step-and-Data-203x300.png 203w, https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/POLQA-Step-and-Data-476x705.png 476w, https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/POLQA-Step-and-Data.png 538w\" sizes=\"(max-width: 180px) 100vw, 180px\" \/><\/a>The optional POLQA (Perceptual Objective Listening Quality Analysis) module brings POLQA analysis right into SoundCheck, for perceptual measurements of speech degradation in communications applications ranging from telephones to smart devices. It may be used to assess the impact of noise reduction algorithms, evaluate Bluetooth degradation due to packet loss, or to analyze distortions introduced into the audio path. Naturally, it can be used within sequences to accelerate and simplify test procedures.<\/p>\n<p><strong>Batch Processing of external files<\/strong><br \/>\nWhile SoundCheck has offered batch processing of collected data since 2012, version 20 extends this with the ability to automatically load and process external data. This is useful in any application where it is desirable to automate the testing of a large number of external data files via a sequence, for example wav files of speech recordings. This has many uses in communications testing, for example in testing the Mean Opinion Score (MOS) of degraded speech files.<\/p>\n<p><strong>New Features for Communications Testing<\/strong><br \/>\n<a href=\"https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/Communications-Doubletalk-Level-vs-Time-Example.png\"><img decoding=\"async\" class=\"alignright size-medium wp-image-9614\" src=\"https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/Communications-Doubletalk-Level-vs-Time-Example-300x249.png\" alt=\"\" width=\"300\" height=\"249\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/Communications-Doubletalk-Level-vs-Time-Example-300x249.png 300w, https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/Communications-Doubletalk-Level-vs-Time-Example.png 542w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a>New stimulus steps and post-processing capabilities support communications testing needs, for example, measurement of Doubletalk and other speech transmission parameters. These include a silence stimulus step, and RMS level versus time and histogram post-processing steps. A pre-written test sequence for categorizing Doubletalk performance to two international standards, ITU-T P.502 and ETSI TS 126 132 (part #3114) is also available.<br \/>\nThe silence step inserts a user-defined zero-amplitude signal before or between active signal levels of a compound stimulus step. This is used to synchronize two or more signals in a stimulus step based on measured delays in the device under test.<br \/>\nThe Level vs Time Post Processing step computes the RMS level over time of the selected waveform or group of waveforms within a sequence.<br \/>\nThe Histogram Post Processing step calculates the histogram of a waveform and outputs two curves, the histogram, and the complementary cumulative distribution. This is used for any non-stationary signal analysis such as echo detection in telecommunications or background noise evaluation.<\/p>\n<p><strong>Stimulus editor upgrade<\/strong><br \/>\nThe stimulus editor can now create a stimulus from any waveform in the memory list and equalize and adjust its level, for example using active speech level. This enables such adjustments to be made to externally acquired test signals, such as those imported into SoundCheck via TCP\/IP or recall steps. This is particularly useful for smart device certification testing.<\/p>\n<p><strong>Saving Multichannel Wav files<\/strong><br \/>\nIt is now possible to export multiple SoundCheck recorded waveforms to a single multichannel wav file. This is useful for maintaining channel identification when playing back a multichannel wav file on a device that can only play wav files.<\/p>\n<p><strong>Hardware Reset<\/strong><br \/>\nA new hardware reset option in the set-up wizard allows audio interfaces to be changed without the need to reconfigure channels, and offers a fast way of restoring hardware to a known configuration.<\/p>\n<p><a href=\"https:\/\/www.listeninc.com\/wp\/media\/2022\/07\/SC20_New-Features_20220705.pdf\">Download SoundCheck 20 New Features PDF <\/a> <a href=\"https:\/\/www.listeninc.com\/wp\/media\/2022\/03\/SC20_New-Features.pdf\"><img decoding=\"async\" class=\"alignnone wp-image-2556 size-full\" src=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg\" alt=\"download_pdf_icon\" width=\"50\" height=\"50\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg 50w, https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon-36x36.jpg 36w\" sizes=\"(max-width: 50px) 100vw, 50px\" \/><\/a><\/p>\n<\/div><\/section><br \/>\n<div  class='hr av-lt3e9i3a-5a9a712f1d78dbd1cec5da160fd0afe0 hr-default  avia-builder-el-33  el_after_av_textblock  el_before_av_textblock '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n<section  id=\"version_19\"  class='av_textblock_section av-12ldevo-8ae8f1042d04566a039da97fb724712a '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>SoundCheck New Features: Version 19 (2021)<\/h3>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-l48k3y0r-23-ad8c3e937a7b9c073c15984c2d850b12 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><iframe loading=\"lazy\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/UNZ12w94X9A\" width=\"400\" height=\"225\" frameborder=\"0\" align=\"right\" allowfullscreen=\"allowfullscreen\"><\/iframe><strong><em>SoundCheck 19 builds on recent releases with additional functionality for multichannel measurements, including the new Multi-channel RTA, WASAPI-exclusive mode and AmpConnect 621 control. The incorporation of room acoustics measurements offers increased capability for those looking to evaluate devices in real-world situations. Many of these features also add value on the production line, minimizing setup time, reducing the opportunity for user-errors and ensuring smoother operation in automated situations. <\/em><\/strong><\/p>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-119xt44-bc2c2fddf016ffa9d3fe69f368ac6405 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><strong>Multi-RTA<br \/>\n<\/strong><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC19_MultiRTA.png\"><img decoding=\"async\" class=\"alignright size-medium wp-image-8268\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC19_MultiRTA-300x149.png\" alt=\"\" width=\"300\" height=\"149\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC19_MultiRTA-300x149.png 300w, https:\/\/www.listeninc.com\/wp\/media\/SC19_MultiRTA-768x382.png 768w, https:\/\/www.listeninc.com\/wp\/media\/SC19_MultiRTA-705x351.png 705w, https:\/\/www.listeninc.com\/wp\/media\/SC19_MultiRTA.png 1079w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a>The single-channel RTA is replaced with a new multi-channel version, which enables viewing of multiple signal paths simultaneously. The ability to display multiple channels or signal paths presents a convenient view of many measurements across a wide range of applications. These include overlaying left and right earphone responses to check for fit and seal, microphone array captures (e.g. in-vehicle cabin measurements), real time adjustment of active noise cancellation filter, and more.<br \/>\nSpectrum settings such as gain, octave band, weighting, averaging and time-weighting can be set independently for each channel for complete measurement flexibility. The new Multi RTA also supports a power averaging calculation on the signal paths which can be used for spatial and sound power measurements. All multi-channel RTA functionality can also be used within a test sequence for automation. It conforms to the ANSI S1.11-2004 Class 0 standard.<\/p>\n<p><strong>Room Acoustics RT60 (part # 2050, requires TSR Module Part # 2006)<\/strong><br \/>\n<a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC19_room_acoustics_graph.png\"><img decoding=\"async\" class=\"alignright size-medium wp-image-8270\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC19_room_acoustics_graph-300x130.png\" alt=\"\" width=\"300\" height=\"130\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC19_room_acoustics_graph-300x130.png 300w, https:\/\/www.listeninc.com\/wp\/media\/SC19_room_acoustics_graph.png 613w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a>The optional RT60 Room Acoustics module enables measurement of the reverberation time (signal decay time) and clarity (ratio of early reverberations to late reverberations) of any room or space. This functionality is useful for quantifying how speaker(s) will interact with the acoustics of a particular type of room. It can also help identify problems with room acoustics so that the floor, ceiling and walls can be treated accordingly. The integration of the RT60 functionality within SC provides the user the assurance that measurements can be performed with calibrated signal paths.<br \/>\nSoundCheck offers extremely fast measurements using a continuous sine sweep with the Log TSR algorithm to obtain the impulse response. The reverberation decay curve is calculated from the backwards integrated impulse response. Aside from its speed, this method offers other significant advantages over the traditional direct method &#8211; it requires just one measurement at each location, and minimizes the effect of noise and distortion on the measurement.<\/p>\n<p><strong>WASAPI Exclusive-Mode<\/strong><br \/>\n<a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC19_WASAPI_AC621.png\"><img decoding=\"async\" class=\"alignright size-medium wp-image-8264\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC19_WASAPI_AC621-300x215.png\" alt=\"\" width=\"300\" height=\"215\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC19_WASAPI_AC621-300x215.png 300w, https:\/\/www.listeninc.com\/wp\/media\/SC19_WASAPI_AC621-768x551.png 768w, https:\/\/www.listeninc.com\/wp\/media\/SC19_WASAPI_AC621-260x185.png 260w, https:\/\/www.listeninc.com\/wp\/media\/SC19_WASAPI_AC621-705x505.png 705w, https:\/\/www.listeninc.com\/wp\/media\/SC19_WASAPI_AC621.png 894w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a>SoundCheck now offers the option to operate in WASAPI-exclusive mode. This advanced interface offers superior communication with audio devices in recent versions of Windows, giving SoundCheck greater control over the audio stream. WASAPI-exclusive mode bypasses the Windows audio engine, sending audio streams directly to the device. This delivers lower latency and ensures that sample rate conversion from the built-in Windows audio engine will not occur. It also enables SoundCheck to put an exclusive lock on the audio interface so that a measurement cannot be disrupted by system sounds. It offers significant advantages for multichannel applications, particularly where the channel count requires multiple audio interfaces. Multiple WASAPI devices may be used simultaneously, whereas ASIO driver restrictions prevent this. It is also possible to combine WASAPI and ASIO devices to increase channel availability.<\/p>\n<p><strong>AmpConnect 621 Control<\/strong><br \/>\n<a href=\"https:\/\/www.listeninc.com\/wp\/media\/AmpConnect621_front_angle_sm-1.jpg\"><img decoding=\"async\" class=\"alignright wp-image-8243\" src=\"https:\/\/www.listeninc.com\/wp\/media\/AmpConnect621_front_angle_sm-1-300x112.jpg\" alt=\"\" width=\"400\" height=\"149\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/AmpConnect621_front_angle_sm-1-300x112.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/AmpConnect621_front_angle_sm-1.jpg 400w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/a>SoundCheck 19 supports AmpConnect 621, Listen\u2019s new high resolution (up to 192kHz) multichannel audio interface. AmpConnect 621 has no front panel controls; it is exclusively configured via the SoundCheck 19 software. Set-up and configuration is extremely simple and fast with full plug-and-play functionality and TEDS support for automatic identification, configuration and calibration of microphones and accelerometers. Naturally, the absence of front panel knobs also provides an added level of test integrity by ensuring that settings cannot be inadvertently adjusted outside of your test configuration. SoundCheck 19 with AmpConnect 621 is a simple and cost-effective solution for automotive measurements with a 6-microphone array, sound power measurements, or for measuring devices with multiple speakers such as smartphones or sound bars.<\/p>\n<p><strong>Diagnostic Window<\/strong><br \/>\n<a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC19_Diagnostic_window.png\"><img decoding=\"async\" class=\"alignright size-medium wp-image-8266\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC19_Diagnostic_window-300x84.png\" alt=\"\" width=\"300\" height=\"84\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC19_Diagnostic_window-300x84.png 300w, https:\/\/www.listeninc.com\/wp\/media\/SC19_Diagnostic_window-710x201.png 710w, https:\/\/www.listeninc.com\/wp\/media\/SC19_Diagnostic_window-705x196.png 705w, https:\/\/www.listeninc.com\/wp\/media\/SC19_Diagnostic_window.png 722w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a>The new Diagnostic Window enables the user to suppress warning dialog windows when running a sequence and instead log the errors, warnings, and information in a separate diagnostic window. This is useful when Soundcheck is run in unattended or in highly automated situations (for example, on a production line) where dialog windows would interrupt the execution of a sequence. The error log is easily emailed to the Listen support team to facilitate troubleshooting. The user has full control over what types of errors and warnings are displayed in real time, and which are written to the log.<\/p>\n<p><strong>USB Controller Knob Compatibility<\/strong><br \/>\n<a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC19_USB_Knob.png\"><img decoding=\"async\" class=\"alignright wp-image-8262\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC19_USB_Knob-300x267.png\" alt=\"\" width=\"200\" height=\"178\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC19_USB_Knob-300x267.png 300w, https:\/\/www.listeninc.com\/wp\/media\/SC19_USB_Knob-768x684.png 768w, https:\/\/www.listeninc.com\/wp\/media\/SC19_USB_Knob-705x627.png 705w, https:\/\/www.listeninc.com\/wp\/media\/SC19_USB_Knob.png 900w\" sizes=\"(max-width: 200px) 100vw, 200px\" \/><\/a>SoundCheck now allows use of the Drok USB Controller Knob in both Windows and MacOS to adjust the SoundCheck Signal Generator and simulate the feel of a manual analog signal generator. Used in conjunction with other virtual instruments such as the RTA, spectrum analyzer and distortion meter, this offers a rapid way to identify defects by observing the response while manually fine-tuning the signal generator. The default knob settings can be changed to use keyboard shortcuts built into SoundCheck.<\/p>\n<p><a href=\"https:\/\/content.listeninc.com\/sc19nf\">Download SoundCheck 19 New Features PDF <\/a> <a href=\"https:\/\/content.listeninc.com\/sc19nf\"><img decoding=\"async\" class=\"alignnone wp-image-2556 size-full\" src=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg\" alt=\"download_pdf_icon\" width=\"50\" height=\"50\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg 50w, https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon-36x36.jpg 36w\" sizes=\"(max-width: 50px) 100vw, 50px\" \/><\/a><\/p>\n<\/div><\/section><br \/>\n<div  class='hr av-kmuudd6j-3d4ad98f2e00542eea50c7a97b6a0f80 hr-default  avia-builder-el-37  el_after_av_textblock  el_before_av_textblock '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n<section  id=\"version_19\"  class='av_textblock_section av-12ldevo-22-2b0d7a5d591e252e122f635606c4080e '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>SoundCheck New Features: Version 18 (2020)<\/h3>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-l48k3y0r-21-dcaac267bb2e029616b71f8f47997310 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><iframe loading=\"lazy\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/LUH2WVv_jOI\" width=\"400\" height=\"225\" frameborder=\"0\" align=\"right\" allowfullscreen=\"allowfullscreen\"><\/iframe><strong><em>SoundCheck 18\u2019s new features focus on automation and simplicity. Automation features include the ability to pass test configuration data to and from external programs, and control of MEMS interfaces via a sequence. Setup and test development is simplified with \u2018plug and play\u2019 functionality for Listen hardware, simplified gain control, and improved sampling rate management. <\/em><\/strong><\/p>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-119xt44-20-066f4331270a21f1fbf27109763a7cb3 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><strong>Improved Automation Simplifies Test Sequences<br \/>\n<\/strong><a href=\"https:\/\/www.listeninc.com\/wp\/media\/Sequence_Parameters.png\"><img decoding=\"async\" class=\"alignright size-medium wp-image-6410\" src=\"https:\/\/www.listeninc.com\/wp\/media\/Sequence_Parameters-300x106.png\" alt=\"\" width=\"300\" height=\"106\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/Sequence_Parameters-300x106.png 300w, https:\/\/www.listeninc.com\/wp\/media\/Sequence_Parameters-768x273.png 768w, https:\/\/www.listeninc.com\/wp\/media\/Sequence_Parameters-1300x461.png 1300w, https:\/\/www.listeninc.com\/wp\/media\/Sequence_Parameters-1500x532.png 1500w, https:\/\/www.listeninc.com\/wp\/media\/Sequence_Parameters-705x250.png 705w, https:\/\/www.listeninc.com\/wp\/media\/Sequence_Parameters-1210x423.png 1210w, https:\/\/www.listeninc.com\/wp\/media\/Sequence_Parameters-450x160.png 450w, https:\/\/www.listeninc.com\/wp\/media\/Sequence_Parameters.png 1660w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a>Soundcheck\u2019s new sequence parameter feature allows the user to pass test configuration data into the memory list from external programs using TCP\/IP commands. By externally storing parameters such as limits, test levels, and test signals, a single sequence can be used for multiple products, simplifying the number of sequences that a large organization needs to maintain, and reducing test configuration time.<\/p>\n<p>It is also useful for applications where a sequence needs to be run many times with different parameters, for example, testing voice recognition with a range of voices or test levels. This functionality is particularly useful where SoundCheck tests are run as part of a larger automated test framework controlled using Python, C#, Visual Basic, LabVIEW, etc.<\/p>\n<p><strong>Reduced Set Up Time with Plug and Play Listen Hardware<br \/>\n<\/strong><a href=\"https:\/\/www.listeninc.com\/wp\/media\/Plug-n-Play_2.png\"><img decoding=\"async\" class=\"alignright wp-image-6406\" src=\"https:\/\/www.listeninc.com\/wp\/media\/Plug-n-Play_2-242x300.png\" alt=\"\" width=\"170\" height=\"210\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/Plug-n-Play_2-242x300.png 242w, https:\/\/www.listeninc.com\/wp\/media\/Plug-n-Play_2-768x950.png 768w, https:\/\/www.listeninc.com\/wp\/media\/Plug-n-Play_2-570x705.png 570w, https:\/\/www.listeninc.com\/wp\/media\/Plug-n-Play_2-450x557.png 450w, https:\/\/www.listeninc.com\/wp\/media\/Plug-n-Play_2.png 872w\" sizes=\"(max-width: 170px) 100vw, 170px\" \/><\/a>Improved hardware setup enables you to plug in and make measurements faster. Listen and Portland Tool &amp; Die Hardware are now true \u2018plug-and-play\u2019 which minimizes configuration time, particularly with multichannel interfaces. Simply connect your AmpConnect, BTC-4149 or other Listen interface via the USB cable and the software auto-populates parameters such as sampling rate and calibration values, and creates input and output signal paths.Multiple hardware items are stored within the software, so that they are immediately recognized when connected, and the software will automatically default to the correct device.When substituting devices of the same type, SoundCheck will re-use the configuration previously set up, either manually or during a sequence, so that signal paths and sequence configurations do not need to be updated. This makes deploying a sequence over multiple stations simpler and faster and will offer significant time-savings for large-scale operations who need to configure multiple stations or move hardware around between stations.<\/p>\n<p><strong>Simplified Gain Control Selection<br \/>\n<\/strong><a href=\"https:\/\/www.listeninc.com\/wp\/media\/Gain_Control_1.png\"><img decoding=\"async\" class=\"alignright wp-image-6402\" src=\"https:\/\/www.listeninc.com\/wp\/media\/Gain_Control_1-162x300.png\" alt=\"\" width=\"132\" height=\"244\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/Gain_Control_1-162x300.png 162w, https:\/\/www.listeninc.com\/wp\/media\/Gain_Control_1-381x705.png 381w, https:\/\/www.listeninc.com\/wp\/media\/Gain_Control_1-450x833.png 450w, https:\/\/www.listeninc.com\/wp\/media\/Gain_Control_1.png 500w\" sizes=\"(max-width: 132px) 100vw, 132px\" \/><\/a>Auto read and auto range gain settings are now easily accessible as drop-down options in the gain menu in the acquisition step editor, and auto-read is available in virtual instruments. Setting the gain to auto-read, means that SoundCheck will automatically adjust the gain based on manual input from the user, making it much faster to make quick gain adjustments while developing sequences. When the gain is set to auto range, SoundCheck will automatically identify the correct level of gain to optimize the measurement signal to noise ratio. This makes it fast and simple to optimize tests in the R&amp;D lab for the correct gain before transferring them to production.<\/p>\n<p><strong>Improved sampling rate management<br \/>\n<\/strong>Many audio interfaces have a latency that is dependent on the sampling rate, and SoundCheck 18 brings improved communication with these devices. Firstly, for any hardware device, the user can specify the latencies for various sampling rates, either by entering them manually or importing from a file. SoundCheck will then automatically use the correct latency for any sampling rate specified in the stimulus editor. Secondly, the sampling rate can now be set in the stimulus editor. This is useful for users who need to do iterative tests involving multiple sampling rates and\/or set the <a href=\"https:\/\/www.listeninc.com\/wp\/media\/Sampling_rates_2.png\"><img decoding=\"async\" class=\"alignright wp-image-6408\" src=\"https:\/\/www.listeninc.com\/wp\/media\/Sampling_rates_2-300x292.png\" alt=\"\" width=\"263\" height=\"256\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/Sampling_rates_2-300x292.png 300w, https:\/\/www.listeninc.com\/wp\/media\/Sampling_rates_2-768x746.png 768w, https:\/\/www.listeninc.com\/wp\/media\/Sampling_rates_2-1300x1263.png 1300w, https:\/\/www.listeninc.com\/wp\/media\/Sampling_rates_2-36x36.png 36w, https:\/\/www.listeninc.com\/wp\/media\/Sampling_rates_2-705x685.png 705w, https:\/\/www.listeninc.com\/wp\/media\/Sampling_rates_2-450x437.png 450w, https:\/\/www.listeninc.com\/wp\/media\/Sampling_rates_2.png 1311w\" sizes=\"(max-width: 263px) 100vw, 263px\" \/><\/a>sampling rate via a sequence. Finally, when using WAV files, the sampling rate no longer needs to be manually set to match the sampling rate of the WAV file. This makes it simpler to switch between WAV files, and is useful for anyone making measurements with wave file signals such as speech or music.<\/p>\n<p><strong>New Digital I\/O Control<br \/>\n<\/strong>Digital I\/O control is now a separate message step. This means that all controls for I\/O settings are completely separate from other AmpConnect settings, minimizing the possibility of other parameters such as gain or routing being accidentally modified. The new settings offer a uniform appearance and switching scheme across all devices with digital I\/O control, so that sequences written, for example, with NI hardware, are easily converted to work with AmpConnect.<\/p>\n<p><strong>MEMS Interface control<br \/>\n<\/strong>The Portland Tool &amp; Die MEMS microphone interfaces can now be fully <a href=\"https:\/\/www.listeninc.com\/wp\/media\/Digital_IO.png\"><img decoding=\"async\" class=\"alignright wp-image-6400\" src=\"https:\/\/www.listeninc.com\/wp\/media\/Digital_IO-300x295.png\" alt=\"\" width=\"254\" height=\"250\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/Digital_IO-300x295.png 300w, https:\/\/www.listeninc.com\/wp\/media\/Digital_IO-80x80.png 80w, https:\/\/www.listeninc.com\/wp\/media\/Digital_IO-36x36.png 36w, https:\/\/www.listeninc.com\/wp\/media\/Digital_IO-450x443.png 450w, https:\/\/www.listeninc.com\/wp\/media\/Digital_IO.png 692w\" sizes=\"(max-width: 254px) 100vw, 254px\" \/><\/a>controlled from within SoundCheck. This offers faster setup of the measurement interfaces with SoundCheck as well as greater measurement reliability as the device settings can be built into the test sequence. Sequences using the R&amp;D grade DCC-1448 interface will also work seamlessly with the production-grade PQC-1448, making it much simpler to transition sequences from the R&amp;D lab to the production line.<\/p>\n<p><strong>TEDS support<br \/>\n<\/strong>TEDS Support (with compatible Listen hardware) enables automatic identification, configuration and calibration of TEDS microphones and accelerometers, saving time on initial hardware setup and whenever hardware is changed.<\/p>\n<p><strong>WASAPI Driver support<br \/>\n<\/strong>SoundCheck 18 now includes WASAPI driver support in Windows 10. This driver offers full multichannel support, allowing each individual channel to display separately in the hardware editor, rather than as channel pairs.<\/p>\n<p><strong>AmpConnect 621 Control (New in Version 18.1)<br \/>\n<\/strong>SoundCheck 18.1 introduces control for the new AmpConnect 621 interface. This all-in-one multichannel interface (6-in, 2-out) has no front-panel controls and is exclusively controlled via the software. This minimizes potential operator error and ensures seamless integration with test sequences and virtual instruments.<\/p>\n<p><strong>New Auto Delay+ Algorithm (New in Version 18.1)<br \/>\n<\/strong>The new Auto Delay+ algorithm offers increased accuracy for open loop measurements, especially in cases where the delay is longer than 1 second. It is particularly useful for measuring smart devices such as smart speakers, automotive audio, hearables, etc., where test signals are sent via the cloud.<\/p>\n<p><a href=\"https:\/\/content.listeninc.com\/sc18nf\">Download SoundCheck 18 New Features PDF <\/a> <a href=\"https:\/\/content.listeninc.com\/sc18nf\"><img decoding=\"async\" class=\"alignnone wp-image-2556 size-full\" src=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg\" alt=\"download_pdf_icon\" width=\"50\" height=\"50\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg 50w, https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon-36x36.jpg 36w\" sizes=\"(max-width: 50px) 100vw, 50px\" \/><\/a><\/p>\n<\/div><\/section><br \/>\n<div  class='hr av-kmuudd6j-19-735a9a4732c5128be6560677ebcdaa38 hr-default  avia-builder-el-41  el_after_av_textblock  el_before_av_textblock '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n<section  id=\"version_19\"  class='av_textblock_section av-12ldevo-18-7125afc73a255dc52d9dadebb260877d '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>SoundCheck New Features: Version 17 (2019)<\/h3>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-l48k3y0r-17-7b2851dd957d808d4e5cfe92167cb8b1 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><iframe loading=\"lazy\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/krYEQWZcFAY\" width=\"400\" height=\"225\" frameborder=\"0\" align=\"right\" allowfullscreen=\"allowfullscreen\"><\/iframe><strong><em>This new Windows\/Mac release offers many features to simplify multi-channel and voice controlled testing, such as a new level and cross-correlation trigger, average curve\/waveform post-processing functionality, the ability to easily read and work with multichannel wavefiles, multiple DC Connect control, and enhanced database options (useful when processing data from a large number of channels). On the usability side, SoundCheck 17 offers increased flexibility in color pallets, save to MATLAB option, and the ability to recall CSV formatted text files.<\/em><\/strong><\/p>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-119xt44-16-771e3d86bd340ae6f20345fd7148dcdf '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><div id=\"attachment_5602\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC17_new_color_palette.png\"><img decoding=\"async\" aria-describedby=\"caption-attachment-5602\" class=\"wp-image-5602 size-medium\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC17_new_color_palette-300x283.png\" alt=\"\" width=\"300\" height=\"283\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC17_new_color_palette-300x283.png 300w, https:\/\/www.listeninc.com\/wp\/media\/SC17_new_color_palette-450x424.png 450w, https:\/\/www.listeninc.com\/wp\/media\/SC17_new_color_palette.png 554w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-5602\" class=\"wp-caption-text\">New Color Palette<\/p><\/div>\n<p><strong>Improved Display Color Palettes<\/strong><br \/>\nImproved color pallets offer ultimate flexibility in defining colors for backgrounds, grids, cursors and graph lines. New default color palettes are included, and user-defined palettes can be saved as pre-set files which will be applied to any new display created. Multiple palettes can be saved, for example allowing different color sets for different applications.<\/p>\n<p><strong>Save to MATLAB<\/strong><br \/>\nAll data including memory list curves and Soundmap (time frequency analysis) data can now be saved to MATLAB for additional processing. Data is saved as a standard MAT file and can be manually or automatically saved in this format.<\/p>\n<p><strong>Level &amp; Cross-Correlation Trigger<\/strong><br \/>\n(requires optional module 2006 \u2013 Time Selective Response)<br \/>\nA new cross-correlation \u2018smart trigger\u2019 offers improved performance for open loop measurements. By using a chirp-based conditioning tone and searching for the exact log sweep frequency, it is more robust and less<\/p>\n<div id=\"attachment_5606\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC17_save_to_matlab.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-5606\" class=\"wp-image-5606 size-medium\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC17_save_to_matlab-300x194.jpg\" alt=\"\" width=\"300\" height=\"194\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC17_save_to_matlab-300x194.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/SC17_save_to_matlab-768x498.jpg 768w, https:\/\/www.listeninc.com\/wp\/media\/SC17_save_to_matlab-1300x843.jpg 1300w, https:\/\/www.listeninc.com\/wp\/media\/SC17_save_to_matlab-1500x972.jpg 1500w, https:\/\/www.listeninc.com\/wp\/media\/SC17_save_to_matlab-705x457.jpg 705w, https:\/\/www.listeninc.com\/wp\/media\/SC17_save_to_matlab-450x292.jpg 450w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-5606\" class=\"wp-caption-text\">Save To MATLAB<\/p><\/div>\n<p>susceptible to false triggers than simpler level and frequency triggers. This feature requires optional module 2006 (time selective response) to be installed.<\/p>\n<p><strong>Enhanced Database (optional module)<\/strong><br \/>\nThe improved database module is a powerful data management tool for customers testing modern audio products with multiple transducers (microphone arrays, multiple speakers, etc.), as these frequently generate large volumes of data. It is also extremely valuable for production line users who need to retain complete test data for full traceability. Enhancements in version 17 make it 4x faster and 3x more space-efficient than previous versions. Such speed is achieved by saving to a binary format; SQL and Python tools are provided to facilitate data extraction so that detailed analysis and graphical representation may be implemented in your Business Intelligence (BI) system of choice (e.g. Tableau, Qlik,etc.).<\/p>\n<p><div id=\"attachment_5598\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC17_Level_and_Cross_Correlation_Stweep.png\"><img decoding=\"async\" aria-describedby=\"caption-attachment-5598\" class=\"wp-image-5598 size-medium\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC17_Level_and_Cross_Correlation_Stweep-300x254.png\" alt=\"\" width=\"300\" height=\"254\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC17_Level_and_Cross_Correlation_Stweep-300x254.png 300w, https:\/\/www.listeninc.com\/wp\/media\/SC17_Level_and_Cross_Correlation_Stweep-705x597.png 705w, https:\/\/www.listeninc.com\/wp\/media\/SC17_Level_and_Cross_Correlation_Stweep-450x381.png 450w, https:\/\/www.listeninc.com\/wp\/media\/SC17_Level_and_Cross_Correlation_Stweep.png 709w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-5598\" class=\"wp-caption-text\">New Level and Cross-Correlation Trigger<\/p><\/div><br \/>\n<div id=\"attachment_5604\" style=\"width: 234px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC17_Save_to_DB.png\"><img decoding=\"async\" aria-describedby=\"caption-attachment-5604\" class=\"wp-image-5604 size-medium\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC17_Save_to_DB-224x300.png\" alt=\"\" width=\"224\" height=\"300\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC17_Save_to_DB-224x300.png 224w, https:\/\/www.listeninc.com\/wp\/media\/SC17_Save_to_DB-768x1027.png 768w, https:\/\/www.listeninc.com\/wp\/media\/SC17_Save_to_DB-527x705.png 527w, https:\/\/www.listeninc.com\/wp\/media\/SC17_Save_to_DB-450x602.png 450w, https:\/\/www.listeninc.com\/wp\/media\/SC17_Save_to_DB.png 891w\" sizes=\"(max-width: 224px) 100vw, 224px\" \/><\/a><p id=\"caption-attachment-5604\" class=\"wp-caption-text\">Autosave to Database<\/p><\/div><\/p>\n<p><strong>Read Multichannel WAV Files<\/strong><br \/>\nTesting of multichannel devices such as microphone or speaker arrays is much easier and faster as SoundCheck now reads multichannel WAV files from the memory list, signal generator and stimulus steps; there is no need to de-interleave the files in a separate utility before importing into SoundCheck. When opening a multichannel WAV file in the Memory list, each WAV file channel is named using the file name and channel number, and all channels are automatically grouped together.<\/p>\n<p><strong>Control Multiple DC Connects<\/strong><br \/>\nAlso for testing multi-channel devices, multiple DC Connects can now be controlled and used for data acquisition within SoundCheck. Separate DC Connect message steps can be used to configure each DC connect (output modes, signal level, polarity, voltage level, current level etc.) independently.<\/p>\n<p><strong>Average Curve\/Waveform<\/strong><br \/>\nAverage Curve\/WFM is a new post processing function that allows you to obtain the average curve (or waveform) of a selected group of data in the Memory List. It is particularly useful for power averaging selected curves, averaging curves from different spatial positions (e.g. microphone arrays), and complex averaging of multiple measurements with background noise.<\/p>\n<p><strong>Supports New APTX HD Codec<\/strong><br \/>\nThe new APTX HD codec for high resolution Bluetooth testing is supported in the SoundCheck software, and also in the newest version of the BTC Bluetooth Interface, which is fully integrated with, and controlled by, SoundCheck.<\/p>\n<div id=\"attachment_5600\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC17_Multichannel_WAV_Stimulus.png\"><img decoding=\"async\" aria-describedby=\"caption-attachment-5600\" class=\"wp-image-5600 size-medium\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC17_Multichannel_WAV_Stimulus-300x265.png\" alt=\"\" width=\"300\" height=\"265\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC17_Multichannel_WAV_Stimulus-300x265.png 300w, https:\/\/www.listeninc.com\/wp\/media\/SC17_Multichannel_WAV_Stimulus-705x622.png 705w, https:\/\/www.listeninc.com\/wp\/media\/SC17_Multichannel_WAV_Stimulus-450x397.png 450w, https:\/\/www.listeninc.com\/wp\/media\/SC17_Multichannel_WAV_Stimulus.png 709w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-5600\" class=\"wp-caption-text\">Read MultiChannel WAV files<\/p><\/div>\n<p><strong>64 bit Demo \/ Data Viewer<\/strong><br \/>\nA 64 bit demo \/ data viewer replaces the 32 bit demo version. When the software key is not installed, previously measured data can still be recalled and viewed. For users who wish to additionally process stored data but have no need to acquire it, cost effective limited licenses are available.<\/p>\n<div id=\"attachment_5596\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC17_Average_Curve_display.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-5596\" class=\"wp-image-5596 size-medium\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC17_Average_Curve_display-300x136.jpg\" alt=\"\" width=\"300\" height=\"136\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC17_Average_Curve_display-300x136.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/SC17_Average_Curve_display-768x347.jpg 768w, https:\/\/www.listeninc.com\/wp\/media\/SC17_Average_Curve_display-705x319.jpg 705w, https:\/\/www.listeninc.com\/wp\/media\/SC17_Average_Curve_display-450x203.jpg 450w, https:\/\/www.listeninc.com\/wp\/media\/SC17_Average_Curve_display.jpg 1049w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-5596\" class=\"wp-caption-text\">Average Curve \/ Waveform<\/p><\/div>\n<p><strong>Recall from CSV<\/strong><br \/>\nCSV files can be recalled in addition to TXT files. A separate IMP file for the CSV format can be created allowing for automatic recall of CSV files. This makes its easier to recall pre-formatted text files.<\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><a href=\"https:\/\/content.listeninc.com\/SC17NewFeatures\">Download SoundCheck 17 New Features PDF <\/a> <a href=\"https:\/\/content.listeninc.com\/SC17NewFeatures\"><img decoding=\"async\" class=\"alignnone wp-image-2556 size-full\" src=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg\" alt=\"download_pdf_icon\" width=\"50\" height=\"50\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg 50w, https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon-36x36.jpg 36w\" sizes=\"(max-width: 50px) 100vw, 50px\" \/><\/a><\/p>\n<\/div><\/section><br \/>\n<div  class='hr av-kmuudd6j-15-529351c94fdc6d14b6c5bf1d4fccbff6 hr-default  avia-builder-el-45  el_after_av_textblock  el_before_av_textblock '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n<section  class='av_textblock_section av-12ldevo-14-1b9d966c88756f7dac3f40147df75ea1 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>SoundCheck New Features: Version 16 \/ 16.1 (2017\/2018)<\/h3>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-l48k3y0r-13-bcd8c85a28c8dc575402e50d8cc648c6 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><iframe loading=\"lazy\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/FClYx0kHmaM\" width=\"400\" height=\"225\" frameborder=\"0\" align=\"right\" allowfullscreen=\"allowfullscreen\"><\/iframe><strong><em>This feature-packed Windows\/Mac release includes several new features and algorithms for distortion measurements, a new frequency counter, optional strip chart recorder that emulates a traditional strip chart and more. There are also improvements on the usability side including increased setup automation and control via Python.<\/em><\/strong><\/p>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-119xt44-12-0306796807d28d57d80b16b0ec0a68c7 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><div id=\"attachment_4550\" style=\"width: 155px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/Amp_THD-N_Default_Seq_1.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-4550\" class=\"wp-image-4550 size-medium\" src=\"https:\/\/www.listeninc.com\/wp\/media\/Amp_THD-N_Default_Seq_1-145x300.jpg\" width=\"145\" height=\"300\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/Amp_THD-N_Default_Seq_1-145x300.jpg 145w, https:\/\/www.listeninc.com\/wp\/media\/Amp_THD-N_Default_Seq_1.jpg 340w\" sizes=\"(max-width: 145px) 100vw, 145px\" \/><\/a><p id=\"caption-attachment-4550\" class=\"wp-caption-text\">Faster, more accurate THD+N algorithm<\/p><\/div>\n<p><strong>Frequency Trigger<br \/>\n<\/strong>The new frequency trigger allows frequency-based triggering of acquisition from an external source using a pilot tone at the beginning of a test sweep. This allows for improved accuracy over previous level-based triggering when capturing responses from a device where you don\u2019t have direct access to the microphone or speaker. This is otherwise known as Open Loop testing for Smart Speakers and other voice-controlled devices. (<a href=\"https:\/\/content.listeninc.com\/frequency_trigger_video\">watch video demo<\/a>)<\/p>\n<p><strong>Faster &amp; more accurate THD+N analysis algorithm<\/strong><br \/>\nListen\u2019s completely re-designed THD+N analysis algorithm is compliant with the AES17 standard, and is more accurate and significantly faster than other audio test systems. High accuracy is achieved, even with short and\/or low level test signals, through the use of a synthetic notch filter &#8211; an extremely precise digital notch filter. A traditional notch filter option is also offered to enable correlation with measurements made on legacy systems. The algorithm also includes high and low pass filters for controlling the measurement bandwidth and for filtering noise in electronic measurements.<\/p>\n<p><strong>New Real Time Distortion Analyzer (optional module)<\/strong><br \/>\nA new distortion analyzer provides continuous real time measurement of output distortion including THD and THD+N, THD and THD+N residual level and SINAD. A, B, and C weighting filters along with user-defined arbitrary weighting functions can be used. Data from the distortion analyzer can also be saved to the memory list. This enables distortion to be quickly viewed without having to set up a sequence. With the optional strip chart recorder, distortion can also be viewed over time.<\/p>\n<p>New Real Time Distortion Analyzer<\/p>\n<p><strong>New Frequency Counter (optional module)<\/strong><br \/>\nThe new high resolution frequency counter offers an accurate and clear visual indication of frequency, determining the dominant signal in a selected signal path and returning a precise frequency measurement. This measurement can be saved <a href=\"https:\/\/www.listeninc.com\/wp\/media\/Distortion_Analyzer_3.jpg\"><img decoding=\"async\" class=\"wp-image-4551 size-medium alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/Distortion_Analyzer_3-160x300.jpg\" width=\"160\" height=\"300\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/Distortion_Analyzer_3-160x300.jpg 160w, https:\/\/www.listeninc.com\/wp\/media\/Distortion_Analyzer_3.jpg 340w\" sizes=\"(max-width: 160px) 100vw, 160px\" \/><\/a>to the memory list and can be used in a sequence, for example for triggering a measurement at a certain frequency. This feature is useful for calibration (e.g. calibrating audiometers), for testing playback systems to ensure that they are playing back audio at a constant rate, and for any other application requiring a high-precision frequency measurement.<\/p>\n<p><strong>Save to Memory List for All Meters<\/strong><br \/>\nThe multimeter, distortion analyzer and frequency counter can all now save results to the memory list, even when used interactively. This enables an instantaneous measurement to be recorded without having to run a sequence, and also enables these saved values to be used within sequences.<\/p>\n<p><strong>New Strip Chart Recorder (optional module)<\/strong><br \/>\nThe Strip Chart Recorder module provides the multimeter, distortion analyzer and frequency counter the ability to plot measurements over time. This functionality is directly equivalent to connecting a paper chart recorder to a classic, stand-alone hardware instrument. The Strip Chart Recorder can plot continuously or for a predefined amount of time and can plot instantaneous results or repeating averages. This is an invaluable feature for environmental and reliability testing and for any engineer that needs to characterize the behavior of a device over time. Results from the Strip Chart Recorder can be saved to the memory list and used inside a sequence just like any other virtual instrument.<\/p>\n<div id=\"attachment_4554\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/THDN-vs-Time-Strip-Chart.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-4554\" class=\"wp-image-4554 size-medium\" src=\"https:\/\/www.listeninc.com\/wp\/media\/THDN-vs-Time-Strip-Chart-300x176.jpg\" width=\"300\" height=\"176\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/THDN-vs-Time-Strip-Chart-300x176.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/THDN-vs-Time-Strip-Chart.jpg 495w, https:\/\/www.listeninc.com\/wp\/media\/THDN-vs-Time-Strip-Chart-450x265.jpg 450w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-4554\" class=\"wp-caption-text\">New Strip Chart Recorder<\/p><\/div>\n<p><strong>Sweep Equalization for Minimized Transients<\/strong><br \/>\nIn stepped sine amplitude and frequency sweeps, selecting equalization now also enables a smooth transition between steps. These smooth transitions minimize the transient response in the device under test. This results in shorter test times, smoother sounding sweeps, and is particularly useful for microphone testing where a source speaker needs to be equalized.<\/p>\n<p><strong>Upgraded Multimeter<br \/>\n<\/strong>The multimeter has a new, fixed or auto-tracking bandpass filter option. This is useful for measuring a specific signal in the presence of background noise. In addition a new \u2018Linear Repeating\u2019 averaging mode is available. In this mode a linear average is made and then repeated. This is useful when, for example, you would like to plot a repeating 1 second Leq of the environmental noise level.<\/p>\n<div id=\"attachment_4553\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC16_smooth_transitions.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-4553\" class=\"wp-image-4553 size-medium\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC16_smooth_transitions-300x110.jpg\" width=\"300\" height=\"110\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC16_smooth_transitions-300x110.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/SC16_smooth_transitions-768x282.jpg 768w, https:\/\/www.listeninc.com\/wp\/media\/SC16_smooth_transitions-705x259.jpg 705w, https:\/\/www.listeninc.com\/wp\/media\/SC16_smooth_transitions-450x165.jpg 450w, https:\/\/www.listeninc.com\/wp\/media\/SC16_smooth_transitions.jpg 800w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-4553\" class=\"wp-caption-text\">Sweep with and without equalization<\/p><\/div>\n<p><strong>Simplified Setup<\/strong><br \/>\nSoundCheck automatically scans for new devices and setting changes when opened, and updates the Hardware Editor, Audio Hardware and Listen Hardware Tabs. This makes setup much faster. The ability to also manually adjust hardware setup and preserve 3rd party hardware settings offers flexibility and makes it easier to integrate Listen and 3rd party hardware. To simplify audio interface setup, sample rates are restricted to the selection valid for that device. If changes are made during a SoundCheck session, a simple \u2018refresh\u2019 will scan for changes and update the settings.Software installation for multiple systems is also simplified; when pointing to a folder of multiple status.dat files in the setup wizard, the correct status.dat file is automatically selected based on the connected hardware key.<br \/>\nA new conversion tool facilitates updating custom VIs from an older version to the latest version of SoundCheck by automatically re-linking the appropriate vi and ctl files, saving time over doing it manually.<\/p>\n<div id=\"attachment_4552\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/Outline-ET250-3D_01-1.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-4552\" class=\"wp-image-4552 size-medium\" src=\"https:\/\/www.listeninc.com\/wp\/media\/Outline-ET250-3D_01-1-300x202.jpg\" width=\"300\" height=\"202\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/Outline-ET250-3D_01-1-300x202.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/Outline-ET250-3D_01-1-450x303.jpg 450w, https:\/\/www.listeninc.com\/wp\/media\/Outline-ET250-3D_01-1.jpg 600w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-4552\" class=\"wp-caption-text\">Outline Turntable<\/p><\/div>\n<p><strong>Outline ET250-3D Turntable Control<\/strong><br \/>\nCustom Steps are available to control the Outline Turntable model ET250-3D, and an example sequence is available.<\/p>\n<p><strong>SoundCheck Control Via Python<\/strong><br \/>\nSoundCheck can be controlled via Python, an object-oriented scripting language that offers some advantages over C++. An included example (which can be used as a starting point and modified) demonstrates the simplicity of controlling SoundCheck using Python. Compatible with Python 2 and 3, this script opens SoundCheck, loads and runs the \u201cComplete Test\u201d sequence, and passes results back to the Python script for further processing.<\/p>\n<p><strong>Externally Launch and Close Virtual Instruments<\/strong><br \/>\nA new virtual instrument wrapper allows you to open and close virtual instruments from a custom VI or using TCP\/IP.<\/p>\n<p><strong>The Exit Status of Custom Steps Is Now Indicated<\/strong><br \/>\nLike other SoundCheck steps, the Sequence Editor now highlights in red or green whether a custom step completed successfully or not.<\/p>\n<p><strong><a href=\"https:\/\/content.listeninc.com\/SC16NewFeatures\">Download SoundCheck 16 New Features PDF <\/a> <a href=\"https:\/\/content.listeninc.com\/SC16NewFeatures\"><img decoding=\"async\" class=\"alignnone wp-image-2556 size-full\" src=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg\" alt=\"download_pdf_icon\" width=\"50\" height=\"50\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg 50w, https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon-36x36.jpg 36w\" sizes=\"(max-width: 50px) 100vw, 50px\" \/><\/a><\/strong><\/p>\n<\/div><\/section><br \/>\n<div  class='hr av-104wedw-229fe46d1e98a22c8b1806faca467412 hr-default  avia-builder-el-49  el_after_av_textblock  el_before_av_textblock '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n<section  class='av_textblock_section av-yfaof8-feb7e8b11c740b7d3829ac4dcadd7a7a '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>SoundCheck New Features: Version 15 (2016)<\/h3>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-l48k3y0r-11-a6c5e67f569880385b12efe36fe46063 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><iframe loading=\"lazy\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/Rm6bN5yZpuk\" width=\"400\" height=\"225\" frameborder=\"0\" align=\"right\" allowfullscreen=\"allowfullscreen\"><\/iframe><strong><em>This feature-packed Windows\/Mac release includes several new features and algorithms for distortion measurements, a new frequency counter, optional strip chart recorder that emulates a traditional strip chart and more. There are also improvements on the usability side including increased setup automation and control via Python.<\/em><\/strong><\/p>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-w8wyms-834d21b1ab2324c285d8ecfc024ba92a '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><strong>More Powerful Control with TCP\/IP<\/strong><br \/>\nExternal control of SoundCheck is simpler, yet more powerful with the new TCP\/IP control. This offers many advantages over the previous Active X controls (still available), such as the ability to connect to SoundCheck via any programming language, on any operating system, either locally or through\u00a0 a network. It also features a more powerful and expandable command format for interacting with SoundCheck. This is extremely valuable for anyone who needs to control SoundCheck from an external program, for example as part of an overall test plan or factory automation. Using this feature, a single computer can control multiple SoundCheck systems, simplifying production line measurements.<\/p>\n<div id=\"attachment_3988\" style=\"width: 176px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/sc-15_multimeter.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-3988\" class=\"size-medium wp-image-3988 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/sc-15_multimeter-166x300.jpg\" alt=\"New multimeter\" width=\"166\" height=\"300\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/sc-15_multimeter-166x300.jpg 166w, https:\/\/www.listeninc.com\/wp\/media\/sc-15_multimeter.jpg 280w\" sizes=\"(max-width: 166px) 100vw, 166px\" \/><\/a><p id=\"caption-attachment-3988\" class=\"wp-caption-text\">New multimeter<\/p><\/div>\n<p><strong>New Multimeter<\/strong><\/p>\n<p>SoundCheck\u2019s multimeter has been completely re-designed to offer additional functionality as well as ease of use. An expandable window enables a compact \u2018meter\u2019 view, or an expanded detailed \u2018settings\u2019 view. In \u2018meter\u2019 view, a clear, simple level meter is displayed, which changes color to warn of overload or near overload values. The value is shown in a clear numerical readout, with a choice of linear or log values. The averaging type, weighting type and bandwidth are also displayed.<br \/>\nIn \u2018settings\u2019 view, 4 different tabs for measurement, averaging, filters and limit setting are visible, and options such as linear\/log scale, filtering and weighting options, etc. can be selected. Enhancements to the multimeter\u2019s capabilities include the ability to measure DC voltage in addition to AC voltage, enabling SoundCheck to be used with a DC coupled interface (e.g. the NI 4461) for making DC audio electronic measurements. The addition of high and low pass filters is useful for removing electrical noise for electronic measurements and low frequency background noise for acoustic measurements. A new \u2018autoscaling\u2019 option automatically adjusts the range of the display based on the signal. The multimeter can also now read the dB ref from the memory list.\u00a0 Multimeter settings (range, filters, averaging, etc.) can be saved, loaded and set as default, making it quick to recall commonly used meter settings. The multimeter settings can also be combined with other virtual instruments and the complete virtual instrument set-up saved.<\/p>\n<div id=\"attachment_3986\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/sc-15_legend.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-3986\" class=\"size-medium wp-image-3986 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/sc-15_legend-300x133.jpg\" alt=\"New graph legends\" width=\"300\" height=\"133\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/sc-15_legend-300x133.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/sc-15_legend-768x341.jpg 768w, https:\/\/www.listeninc.com\/wp\/media\/sc-15_legend-705x313.jpg 705w, https:\/\/www.listeninc.com\/wp\/media\/sc-15_legend-450x200.jpg 450w, https:\/\/www.listeninc.com\/wp\/media\/sc-15_legend.jpg 1184w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-3986\" class=\"wp-caption-text\">New graph legends<\/p><\/div>\n<p><strong>Improved Plot Legend Flexibility<\/strong><\/p>\n<p>Additional plot legend options have been added. A toggle makes the plot legend visible or invisible, the legend can be placed at the top or the right of the graph. A new auto-size option re-sizes the plot legend area to show the entire curve or waveform names. When not auto-sized, placing the pointer over a curve or waveform name will display the entire name.<\/p>\n<p><strong>Auto-Mode in Hardware Editor<\/strong><br \/>\nWhen automode is checked,\u00a0 the audio table is automatically refreshed as hardware is plugged and unplugged, without the need to close and reopen the hardware editor to see the changes updated. This makes system set-up faster and simpler.<\/p>\n<div id=\"attachment_3987\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/sc-15_mixer.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-3987\" class=\"wp-image-3987 size-medium alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/sc-15_mixer-300x209.jpg\" alt=\"Improved audio mixer\" width=\"300\" height=\"209\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/sc-15_mixer-300x209.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/sc-15_mixer.jpg 434w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-3987\" class=\"wp-caption-text\">Improved audio mixer<\/p><\/div>\n<p><strong>Control of Bluetooth Interface<\/strong><br \/>\nVarious improvements in the BTC control include faster response, better abort handling and the ability to detect when a connection has failed so that the sequence can decide whether to try again or not.<\/p>\n<p><strong>Improved Audio Mixer<\/strong><\/p>\n<p>The Windows &amp; Mac OS Audio Mixer custom VI has been updated to work with the latest versions of both Windows and Mac OS. This enables controls of any audio input or output via steps in SoundCheck. For example, the volume of a headset may be controlled while testing it, or the levels of a WDM audio device can be fixed at unity gain for consistent calibration.<\/p>\n<p><strong>Support for Accelerometer Calibration and Force Measurement<\/strong><\/p>\n<p>Accelerometer and other\u00a0 vibration transducer calibration and related force units (dB re 1 m\/s2, dB re 1 N and dB re 1 g) are now supported. This enables measurement of linear motors such as those used in haptic devices.<\/p>\n<div id=\"attachment_3985\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/sc-15_accelerometer_calibration.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-3985\" class=\"size-medium wp-image-3985 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/sc-15_accelerometer_calibration-300x212.jpg\" alt=\"Accelerometer calibration\" width=\"300\" height=\"212\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/sc-15_accelerometer_calibration-300x212.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/sc-15_accelerometer_calibration-260x185.jpg 260w, https:\/\/www.listeninc.com\/wp\/media\/sc-15_accelerometer_calibration.jpg 424w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-3985\" class=\"wp-caption-text\">Accelerometer calibration<\/p><\/div>\n<p><strong>Faster Setup with Automatically Selected Status.dat<\/strong><br \/>\nIf the status.dat path is pointed to a folder containing multiple status.dat files, the software will automatically load the one that corresponds to the currently plugged in hardware key. This is useful for customers who are setting up multiple SoundCheck computers, as a single computer image can be created with SoundCheck pre-configured rather than having to set up each individual key on the corresponding computer.<\/p>\n<p><strong><a href=\"https:\/\/content.listeninc.com\/SC15-new-features\">Download SoundCheck 15 New Features PDF <\/a><a href=\"https:\/\/content.listeninc.com\/SC15-new-features\"><img decoding=\"async\" class=\"alignnone wp-image-2556 size-full\" src=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg\" alt=\"download_pdf_icon\" width=\"50\" height=\"50\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg 50w, https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon-36x36.jpg 36w\" sizes=\"(max-width: 50px) 100vw, 50px\" \/><\/a><\/strong><\/p>\n<\/div><\/section><br \/>\n<div  class='hr av-104wedw-10-bff6d544e8fbe9ba995974a04f0f4de2 hr-default  avia-builder-el-53  el_after_av_textblock  el_before_av_textblock '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n<section  class='av_textblock_section av-up5xjo-919c0bf01408bee94d8b264cd956424b '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>SoundCheck New Features: Version 14 (2015)<\/h3>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-l48k3y0r-9-63cdf02b9bd3cc0e13e27014e3bf5ad0 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><iframe loading=\"lazy\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/9oFYDHoqMM0\" width=\"400\" height=\"225\" frameborder=\"0\" align=\"right\" allowfullscreen=\"allowfullscreen\"><\/iframe><strong><em>SoundCheck 14\u2019s release continues the evolution of the simpler, more intuitive user interface started in SoundCheck 13. In this release, hardware has been tightly integrated with the software for easier setup and calibration. Version 14 also marks our first version of the software for OS X.<\/em><\/strong><\/p>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-st1xxw-e3a96e0d27b0633d210daf8de88495b7 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><strong>Listen Hardware Integration<\/strong><br \/>\nSoundCheck 14 provides seamless integration with Listen\u2019s expanding line of hardware products including AmpConnect, DC Connect, SoundConnect 2 and AudioConnect. Simply connect one of these devices to the system via USB, and SoundCheck automatically detects it and configures all necessary settings. This makes the initial system setup quick and easy, even for novice users and non-technical personnel. All Listen hardware products, as well as the Portland Tool &amp; Die BTC-4148 Bluetooth interface can now be directly controlled from within the software, enabling them to be changed as part of a sequence.<\/p>\n<div id=\"attachment_886\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/Listen_Hardware_4_devices_550.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-886\" class=\"alignright wp-image-886 size-medium\" src=\"https:\/\/www.listeninc.com\/wp\/media\/Listen_Hardware_4_devices_550-300x138.jpg\" alt=\"Listen Hardware tab in system hardware editor\" width=\"300\" height=\"138\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/Listen_Hardware_4_devices_550-300x138.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/Listen_Hardware_4_devices_550-705x323.jpg 705w, https:\/\/www.listeninc.com\/wp\/media\/Listen_Hardware_4_devices_550-450x206.jpg 450w, https:\/\/www.listeninc.com\/wp\/media\/Listen_Hardware_4_devices_550.jpg 1200w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-886\" class=\"wp-caption-text\">Listen Hardware tab in system hardware editor<\/p><\/div>\n<p><strong>Hardware Editor Improvement<\/strong><br \/>\nThe hardware editor has been completely overhauled to make it simpler to use. A clear table-structure view makes it easy to see and understand all configured devices at a glance. A new \u2018Auto\u2019 mode allows SoundCheck to detect and maintain any Listen audio interfaces so that most users will never even have to open the hardware editor or modify hardware settings.<\/p>\n<p><strong>Calibration &#8211; Input Gain<\/strong><br \/>\nCalibration input sensitivity has now been divided into two parts: sensitivity of the transducer and preamplifier gain. This allows the user to change the gain of the preamp to optimize the dynamic range of the system without needing to re-calibrate the microphone. Additionally, this gain value can be automatically read and updated from Listen hardware such as AmpConnect, SoundConnect 2 and AudioConnect. This automatic mode allows the user to modify preamplifier gains as necessary for different applications while maintaining a fully calibrated signal path.<\/p>\n<div id=\"attachment_884\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/Auto_Range_On_Ref_Mic_550.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-884\" class=\"alignright wp-image-884 size-medium\" src=\"https:\/\/www.listeninc.com\/wp\/media\/Auto_Range_On_Ref_Mic_550-300x138.jpg\" alt=\"New auto-ranging feature\" width=\"300\" height=\"138\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/Auto_Range_On_Ref_Mic_550-300x138.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/Auto_Range_On_Ref_Mic_550-705x323.jpg 705w, https:\/\/www.listeninc.com\/wp\/media\/Auto_Range_On_Ref_Mic_550-450x206.jpg 450w, https:\/\/www.listeninc.com\/wp\/media\/Auto_Range_On_Ref_Mic_550.jpg 1200w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-884\" class=\"wp-caption-text\">New auto-ranging feature<\/p><\/div>\n<p><strong>Auto-ranging<\/strong><br \/>\nThe new auto-ranging feature allows customers using Listen hardware to automatically adjust the microphone preamplifier gain in order to optimize the dynamic range of the test. When auto-ranging is enabled in an acquisition step, SoundCheck will monitor the digital headroom of the audio interface and if necessary increase or decrease the preamp gain, selecting the optimal setting for maximum signal to noise ratio. If a change to the gain is made the acquisition step runs again with the new settings.<\/p>\n<p><strong>New Search Range Interface<\/strong><br \/>\nMany post processing operations in SoundCheck have a search range, which allows the user to select discrete points or ranges along the x-axis over which to perform the desired calculation. Examples include scalar functions such as average, max and min, as well as windowing intersection, and more. The SoundCheck 14 version of the search range has been completely updated, and now uses a very simple table control and for the first time allows memory list values to be selected. This means that search range parameters can be variables that are dynamically calculated by the sequence.<\/p>\n<div id=\"attachment_888\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/Search_Range_Editor_550.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-888\" class=\"alignright wp-image-888 size-medium\" src=\"https:\/\/www.listeninc.com\/wp\/media\/Search_Range_Editor_550-300x138.jpg\" alt=\"New search range interface\" width=\"300\" height=\"138\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/Search_Range_Editor_550-300x138.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/Search_Range_Editor_550-705x323.jpg 705w, https:\/\/www.listeninc.com\/wp\/media\/Search_Range_Editor_550-450x206.jpg 450w, https:\/\/www.listeninc.com\/wp\/media\/Search_Range_Editor_550.jpg 1200w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-888\" class=\"wp-caption-text\">New search range interface<\/p><\/div>\n<p><strong>Setup Wizard Enhancements<\/strong><br \/>\nThe Setup Wizard, first introduced in SoundCheck 12 to help users configure new systems and upgrade from existing versions, receives significant changes and improvements in SoundCheck 14. Users are now presented with a menu of choices as to which section of the wizard they would like to run (load status.dat, import settings, update sequences, setup new hardware). The new format allows users the flexibility to run only portions of the wizard as well as to re-run the utilities as they wish. Current SoundCheck customers will benefit from the more powerful capabilities the new wizard offers for updating existing sequences.<\/p>\n<div id=\"attachment_1029\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/Soundcheck_Mac.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-1029\" class=\"alignright wp-image-1029 size-medium\" src=\"https:\/\/www.listeninc.com\/wp\/media\/Soundcheck_Mac-300x138.jpg\" alt=\"SoundCheck for Mac\" width=\"300\" height=\"138\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/Soundcheck_Mac-300x138.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/Soundcheck_Mac-705x323.jpg 705w, https:\/\/www.listeninc.com\/wp\/media\/Soundcheck_Mac-450x206.jpg 450w, https:\/\/www.listeninc.com\/wp\/media\/Soundcheck_Mac.jpg 1200w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-1029\" class=\"wp-caption-text\">SoundCheck for Mac<\/p><\/div>\n<p><strong>SoundCheck for OS X<\/strong><br \/>\nSoundCheck 14 is the first version of the software made available for use on the Macintosh OS. Mac users with Mavericks or Yosemite versions of OS X are now able to run SoundCheck as a native 64-bit application. Sequences, steps, and data files are cross compatible between the Windows and Mac versions, providing versatility when collaborating with other SoundCheck users. Core audio driver support is included, allowing the same hardware to be used on both operating systems.<\/p>\n<p><strong><a href=\"https:\/\/content.listeninc.com\/SC14_new_features\">Download SoundCheck 14 New Features PDF <\/a><a href=\"https:\/\/content.listeninc.com\/SC14_new_features\"><img decoding=\"async\" class=\"alignnone wp-image-2556 size-full\" src=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg\" alt=\"download_pdf_icon\" width=\"50\" height=\"50\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg 50w, https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon-36x36.jpg 36w\" sizes=\"(max-width: 50px) 100vw, 50px\" \/><\/a><\/strong><\/p>\n<\/div><\/section><br \/>\n<div  class='hr av-r4hy04-feca1bea3fc2d434f09b63a567b98938 hr-default  avia-builder-el-57  el_after_av_textblock  el_before_av_textblock '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n<section  class='av_textblock_section av-2l2ylg-304bc977ecf35823453caf5c797dbe4b '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>SoundCheck New Features: Version 13 (2014)<\/h3>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-l48k3y0r-8-c5b877968aeba65ec87deee579d0bd8c '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><iframe loading=\"lazy\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/aX-QeMMmm-0\" width=\"400\" height=\"225\" frameborder=\"0\" align=\"right\" allowfullscreen=\"allowfullscreen\"><\/iframe><strong><em>SoundCheck 13\u2019s release marks a move towards a simpler, more intuitive user interface with standard context-sensitive control and centralized menus. This offers user benefit in the form of faster test development and a more attractive user interface. In addition, improved memory management and a 64 bit version offer faster testing and the option to use longer test signals.<\/em><\/strong><\/p>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-nddtz8-05f1e137c12001a6a611d7e470d44681 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><div id=\"attachment_2442\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC13_Sequence_Editor1.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2442\" class=\"alignright wp-image-2442 size-medium\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC13_Sequence_Editor1-300x163.jpg\" alt=\"SC13_Sequence_Editor\" width=\"300\" height=\"163\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC13_Sequence_Editor1-300x163.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/SC13_Sequence_Editor1.jpg 432w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-2442\" class=\"wp-caption-text\">New Sequence Editor<\/p><\/div>\n<p><strong>New Sequence Editor<\/strong><\/p>\n<p>A complete overhaul of SoundCheck\u2019s sequence editor makes it faster to write, troubleshoot and modify test sequences. The step templates pane now features an expandable tree structure for template categories and can be fully collapsed to maximize sequence space. Single or multiple steps are now added to a sequence or moved within it simply by dragging and dropping, and all other functions are accessed by right clicking on the step.<\/p>\n<p>The sequence editor now runs in parallel with Soundcheck and can remain open when running a sequence. The currently running step is highlighted in the editor for ease of troubleshooting. Users can insert breakpoints into a sequence for debugging purposes; when a breakpoint is reached the sequence pauses, so that the user can view data, edit steps, or insert new steps. New buttons on the main SoundCheck toolbar can then be used to advance the sequence one step at a time or run the remaining steps in the sequence. A portion of the sequence can also be run using the \u2018Run from Here\u2019 option in the right click menu. These new debugging tools make the Sequence Editor an even more powerful development environment.<\/p>\n<p>Undo functionality has also been added to the Sequence Editor both as a right click and familiar Ctrl+Z shortcut. This allows the user to quickly revert changes made when developing and editing sequences.<\/p>\n<div id=\"attachment_2444\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC13_XY_graph1.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2444\" class=\"alignright wp-image-2444 size-medium\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC13_XY_graph1-300x152.jpg\" alt=\"SC13_XY_graph\" width=\"300\" height=\"152\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC13_XY_graph1-300x152.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/SC13_XY_graph1.jpg 432w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-2444\" class=\"wp-caption-text\">Updated X-Y Graph<\/p><\/div>\n<p><strong>New Graphs<\/strong><\/p>\n<p>Updated versions of the XY and Waveform graphs feature a cleaner look and a more intuitive interface. Right click menus and a collapsible toolbar now contain all graph controls, leaving an uncluttered main window with a larger graph. Customizing the appearance of the graph, zooming, setting axis ranges, and even using cursors is simpler and more efficient than ever before.<\/p>\n<p><strong>Improved Memory Management<\/strong><\/p>\n<p>Significant improvements to SoundCheck\u2019s memory management allows the use of longer stimulus signals than ever before, and sequences that use multiple acquisition steps can also keep iterative recorded waveforms in the memory list without incurring significant memory consumption. Customers performing multi-channel measurements will also experience substantial performance gains in SoundCheck 13 due to the lower memory footprint. This is beneficial for R&amp;D applications with complex sequences, in particular in the telephony industry where long speech signals are widely used.<\/p>\n<p><strong>64-Bit Version<\/strong><\/p>\n<div id=\"attachment_2440\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC13_Preferences_Menu.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2440\" class=\"alignright wp-image-2440 size-medium\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC13_Preferences_Menu-300x243.jpg\" alt=\"\" width=\"300\" height=\"243\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC13_Preferences_Menu-300x243.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/SC13_Preferences_Menu.jpg 348w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-2440\" class=\"wp-caption-text\">New Preferences Menu<\/p><\/div>\n<p>SoundCheck is now available in a 64-bit version. This allows the program to access more system memory, which permits the use of much longer stimuli (over 1 minute in length) and allow larger data sets such as DAT files with hundreds of curves to be opened into the memory list for offline analysis and reporting.<\/p>\n<p><strong>SoundCheck ONE<\/strong><\/p>\n<p>SoundCheck ONE has been updated and expanded for its release with SoundCheck 13. SoundCheck ONE is an entry-level SoundCheck system which is essentially a lower cost, simplified, version of SoundCheck coupled with the AmpConnect ISC hardware. SoundCheck ONE offers the capability to test loudspeakers, microphones and headphones within predetermined sequence templates.<\/p>\n<p>Although the user interface is the same as in the full version of SoundCheck, rather than using the Sequence Editor, SoundCheck ONE users are supplied with sequence templates. These templates serve as the starting point for all SoundCheck ONE tests and can be used to generate as many product-specific sequences as desired by selecting parameters such as the stimulus signal, characteristics to be measured, frequency range, level and limits.<\/p>\n<p>SoundCheck ONE is aimed at customers who do not own a full version of SoundCheck and need a low cost and easy to set up system for basic production line tests of loudspeakers, microphones or headphones. While it offers the same accuracy, advanced algorithms and speed as the regular version of SoundCheck, its flexibility and test customization capabilities are restricted. It is a good entry point for a company testing their products for the first time or moving up from a more rudimentary test system. It can be upgraded to the full version at any time for an additional fee.<\/p>\n<div id=\"attachment_2441\" style=\"width: 184px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC13_Quick_Start.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2441\" class=\"alignright wp-image-2441 size-full\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC13_Quick_Start.jpg\" alt=\"SC13_Quick_Start\" width=\"174\" height=\"221\" \/><\/a><p id=\"caption-attachment-2441\" class=\"wp-caption-text\">New Quickstart Menu<\/p><\/div>\n<p><strong>Preferences and Quick Start Menus<\/strong><\/p>\n<p>A new preferences menu consolidates program-wide preferences such as folder paths and background wallpaper into a single menu. This menu also includes new options such as toggling sequence documentation and whether or not to automatically load a sequence on startup. A new Quick Start Menu provides a simple interface for choosing a sequence to open or starting a new sequence. It also allows easy access to recently used sequences as well as examples.<\/p>\n<p><strong>Memory List Values for Time Window<\/strong><\/p>\n<p>The Time Window in the Time Selective Response analysis step can now use values from the memory list. This allows the window to be set dynamically during the sequence using recalled or calculated values rather than fixed.<\/p>\n<p><strong><a href=\"https:\/\/content.listeninc.com\/SC13_new_features\">Download SoundCheck 13 New Features PDF <\/a><a href=\"https:\/\/content.listeninc.com\/SC13_new_features\"><img decoding=\"async\" class=\"alignnone wp-image-2556 size-full\" src=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg\" alt=\"download_pdf_icon\" width=\"50\" height=\"50\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg 50w, https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon-36x36.jpg 36w\" sizes=\"(max-width: 50px) 100vw, 50px\" \/><\/a><\/strong><\/p>\n<\/div><\/section><br \/>\n<div  class='hr av-n3ogtg-17560e99103e078509c3aa19ba43a60e hr-default  avia-builder-el-61  el_after_av_textblock  el_before_av_textblock '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n<section  class='av_textblock_section av-kazf9w-84e6f79b9db542b94617c3ef8db5823e '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>SoundCheck New Features Version 12<\/h3>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-l48k3y0r-7-6c7255f7be3e39943cd7019be113d212 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><iframe loading=\"lazy\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/YlpYc6DwEAY\" width=\"400\" height=\"225\" frameborder=\"0\" align=\"right\" allowfullscreen=\"allowfullscreen\"><\/iframe><strong><em>SoundCheck 12.0 new features offer advantages to both new and established SoundCheck users. Many center around ease of use, sharing sequences and offline data processing \u2013 features requested by many of our customers. Others, such as the statistics enhancements, increase the software\u2019s capabilities.<\/em><\/strong><\/p>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-ik4h84-fda81687386ba201df38fe81b4270be1 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><div id=\"attachment_2447\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC12_3D_polar_plot_showing_tabs.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2447\" class=\"alignright wp-image-2447 size-medium\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC12_3D_polar_plot_showing_tabs-300x203.jpg\" alt=\"Polar Plot Showing New Tabs\" width=\"300\" height=\"203\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC12_3D_polar_plot_showing_tabs-300x203.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/SC12_3D_polar_plot_showing_tabs.jpg 360w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-2447\" class=\"wp-caption-text\">Polar Plot Showing New Tabs<\/p><\/div>\n<p><strong>New Tabs for display steps<\/strong><\/p>\n<p>A new set of tabs below the SoundCheck tool bar allows a user to quickly switch between display steps when viewing sequence results. There is an \u2018offline\u2019 tab, plus tabs for each display step in the sequence. The user can easily switch between data views, or back to the \u2018offline\u2019 tab, which is always present, even outside of a sequence. In the \u2018offline\u2019 tab, data can be examined or analyzed without affecting the layout of the display outputs from the sequence. When a display step tab is selected, the user can view or edit the display for that step. New right click controls also provide easy access to display editor functions. This new feature benefits anyone developing complex test sequences, and saves time when writing reports.<\/p>\n<p><strong>Single File Sequences<\/strong><\/p>\n<p>All parameters related to an automated test script are now stored in the sequence file.\u00a0This simplifies sequence management and updating as only a single .SQC file is needed, even where multiple files are used in a sequence. Parameters are also now localized to the test sequence, to eliminate the risk of accidentally changing other sequences while editing. These changes benefit all users, particularly those who share sequences between systems and facilities.<\/p>\n<p><strong>Relative File Paths<\/strong><\/p>\n<p>File path controls in a sequence step can now be set relative to the folder path of the sequence itself. This is useful when sharing sequences with other SoundCheck users and locations, as it makes it easy to move the sequence and all of its related files (recalled DAT files, WAV file stimuli, etc.) from one place to another. The relative path can even include sub-folders.<\/p>\n<div id=\"attachment_2448\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC12_histogram_statistics-enhancements.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2448\" class=\"alignright wp-image-2448 size-medium\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC12_histogram_statistics-enhancements-300x245.jpg\" alt=\"New Histogram Option in Statistics\" width=\"300\" height=\"245\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC12_histogram_statistics-enhancements-300x245.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/SC12_histogram_statistics-enhancements.jpg 360w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-2448\" class=\"wp-caption-text\">New Histogram Option in Statistics<\/p><\/div>\n<p><strong>New Offline Setting<\/strong><\/p>\n<p>The new offline setting for SoundCheck enables users to open, process, and view data without loading a test sequence. This minimizes the risk of accidentally editing test scripts. In this mode, virtual instruments such as the signal generator, multimeter etc. can also be used. This is especially useful to customers who view data on a regular basis, for example, development engineers who run a series of experiments and then post-process the data or production engineers who need to view large sets of data from the factory.<\/p>\n<p><strong>Statistics Enhancements<\/strong><\/p>\n<p>Several features have been added to the statistics step, mostly in the offline mode. A new Histogram option enables numerical results data from a batch of products to be plotted on a histogram and a bell curve fitted. This is valuable for analysis of production line data, for example plotting a histogram of the sensitivity of a batch of loudspeakers. A new axis selector on\u00a0the best\/worst fit to average and histogram functions enables user-selection of the axis on which statistical analysis is performed, for example phase or magnitude. Usability has also been improved; the data selection list is now separated into curves and values, and within each category items are ordered according to the user\u2019s memory list preference (sequence order or alphabetical order). The display name for the statistical data that is output to the memory list is also user-customizable.<\/p>\n<div id=\"attachment_2449\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC12_waterfall_plot.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2449\" class=\"wp-image-2449 size-medium alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC12_waterfall_plot-300x213.jpg\" alt=\"Waterfall Plot in SoundMap Module\" width=\"300\" height=\"213\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC12_waterfall_plot-300x213.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/SC12_waterfall_plot-260x185.jpg 260w, https:\/\/www.listeninc.com\/wp\/media\/SC12_waterfall_plot.jpg 360w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-2449\" class=\"wp-caption-text\">Waterfall Plot in SoundMap Module<\/p><\/div>\n<p><strong>SoundMap Fully Integrated<\/strong><\/p>\n<p>The SoundMap application for time frequency analysis is now integrated into SoundCheck as an offline processing option with the ability to directly access waveforms from the memory list. Customers who have purchased SoundMap as a stand-alone application will have this module added to their status.dat files, which will unlock the feature in SoundCheck.<\/p>\n<p><strong>Upgrade and Setup Wizard<\/strong><\/p>\n<p>A new upgrade and setup wizard makes it faster to set up a new system or upgrade from a previous version. For new users, it offers tools to assist with hardware setup and inputting appropriate settings. For upgrading users, it simplifies the process of bringing over preferences, hardware and calibration settings, and sequences from an older version.<\/p>\n<p><strong>Save 24-bit WAV Files<\/strong><\/p>\n<p>When saving WAV files from the memory list or via autosave the user can now choose the bit depth for the file, including 8, 16, and 24 bits.<\/p>\n<p><strong><a href=\"https:\/\/content.listeninc.com\/SC12_new_features\">Download SoundCheck 12 New Features PDF <\/a><a href=\"https:\/\/content.listeninc.com\/SC12_new_features\"><img decoding=\"async\" class=\"alignnone wp-image-2556 size-full\" src=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg\" alt=\"download_pdf_icon\" width=\"50\" height=\"50\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon.jpg 50w, https:\/\/www.listeninc.com\/wp\/media\/download_pdf_icon-36x36.jpg 36w\" sizes=\"(max-width: 50px) 100vw, 50px\" \/><\/a><\/strong><\/p>\n<\/div><\/section><br \/>\n<div  class='hr av-h4fero-e9cff17046f58ab65c76e6d7c8331ee9 hr-default  avia-builder-el-65  el_after_av_textblock  el_before_av_textblock '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n<section  class='av_textblock_section av-feptx0-56a2401276a2d2b79109306051c2c97b '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>SoundCheck New Features Version 11<\/h3>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-duiap0-b23f8b9939566206b2482a52fb9aa188 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><strong><em>SoundCheck 11.1<\/em><\/strong><\/p>\n<p><em>SoundCheck 11.1 expands on the new features and functionality introduced in version 11.0 with expanded batch processing capability and full integration of the CLEAR algorithm into SoundCheck ONE. It offers increased flexibility with additional save to WAV file options and signal generator synchronization, and usability improvements such as mass export and hardware and calibration table enhancements.<\/em><\/p>\n<div id=\"attachment_2454\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC11-1_batch_processing_in_limits.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2454\" class=\"alignright wp-image-2454 size-medium\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC11-1_batch_processing_in_limits-300x278.jpg\" alt=\"Batch Processing in Limits\" width=\"300\" height=\"278\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC11-1_batch_processing_in_limits-300x278.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/SC11-1_batch_processing_in_limits.jpg 384w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-2454\" class=\"wp-caption-text\">Batch Processing in Limits<\/p><\/div>\n<p><strong>Batch Processing in Limits and Post Processing<\/strong><\/p>\n<p>Batch processing (introduced in the analysis step in SoundCheck 11.0) is now also available in limits and post processing. In the limits step, this simplifies sequence writing for multi-channel testing as only one step is required to set limits on multiple channels rather than it being necessary to have a separate step per channel. In post-processing, it enables the user to process large data sets quickly offline. This saves time as hundreds of data sets can be processed in one operation instead of having to do each individually. This is useful for engineers who need to look at large quantities of production data and tweak the limits to see the effect on yield, or when it is necessary to change the resolution of many curves. When carrying out post-processing operations on a group of curves, this feature also enables you to be sure that you are applying an identical post-<br \/>\nprocessing operation on all of them.<\/p>\n<p><strong>New Save to WAV file Options<\/strong><\/p>\n<p>SoundCheck 11.1 offers new scaling options when saving to WAV file. In addition to normalized waveforms you can now also select \u2018sound card values\u2019 which scales the WAV file to the full scale deflection of the audio interface digital level, and \u2018user defined\u2019 which scales the waveform relative to a user defined physical unit. Both these new options make it simple to return the measurement back to the physical unit. This is a welcome feature for advanced users who sometimes wish to export data for customized mathematical analysis using other tools such as MatLab\u2122.<\/p>\n<p><strong>CLEAR Algorithm in SoundCheck ONE<\/strong><\/p>\n<p>The CLEAR algorithm for perceptual Rub &amp; Buzz measurement is now fully integrated into SoundCheck ONE where it operates using the log sweep stimulus.<\/p>\n<div id=\"attachment_2456\" style=\"width: 298px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC11-1_synched_signal_generators.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2456\" class=\"size-full wp-image-2456 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC11-1_synched_signal_generators.jpg\" alt=\"Signal Generators Synched in Real Time\" width=\"288\" height=\"221\" \/><\/a><p id=\"caption-attachment-2456\" class=\"wp-caption-text\">Signal Generators Synched in Real Time<\/p><\/div>\n<p><strong>Signal Generator Synchronization<\/strong><\/p>\n<p>Signal generator synchronization allows multiple signal generators to be synched in real time and in a sequence so they will start and stop simultaneously. This is important when checking the phasing of multiple channels such as loudspeaker and microphone arrays.<\/p>\n<p><strong>Mass Export<\/strong><\/p>\n<p>Multiple sequences can now be exported in a single operation. This saves time when upgrading from one version of SoundCheck to another and when transferring your sequences from one system to another.<\/p>\n<p><strong>Active Speech Level Stimulus Control (requires active speech module p\/n 2033)<\/strong><\/p>\n<p>Users with the Active speech module (for telephony applications) can now set the stimulus level using the active speech level of the wavefile rather than the average level of the wavefile.<\/p>\n<div id=\"attachment_2452\" style=\"width: 298px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC11-1_active_speech_level_stim_control.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2452\" class=\"size-full wp-image-2452 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC11-1_active_speech_level_stim_control.jpg\" alt=\"Active Speech Level Stimulus Control\" width=\"288\" height=\"238\" \/><\/a><p id=\"caption-attachment-2452\" class=\"wp-caption-text\">Active Speech Level Stimulus Control<\/p><\/div>\n<p><strong>Hardware and Calibration table enhancements<\/strong><\/p>\n<p>In the table view of the hardware and calibration editors you can now sort the channels by clicking their column header. This simplifies viewing and editing when you have a lot of channels.<\/p>\n<p><strong><em>SoundCheck 11.0<\/em><\/strong><\/p>\n<p><em>In SoundCheck 11.0, a shift from sequence-specific hardware and calibration to a system level hardware and calibration setup simplifies SoundCheck operation and reduces test setup time, while memory list refinements facilitate data management. Test flexibility is increased with the addition of multiple virtual istruments in an acquisition step, waveform batch processing in an analysis step, and the ability to set stimulus frequencies from a memory list value. Algorithm enhancements and additions include active speech level and perceptual Rub &amp; Buzz measurements using a continuous sine sweep (with Log TSR analysis algorithm).<\/em><\/p>\n<p><strong>Global System Hardware and Calibration<\/strong><\/p>\n<p>SoundCheck 11 brings a shift from sequence-specific hardware and calibration to a system level hardware and calibration setup. This significant change means that the user only needs to enter the hardware configuration once and it will remain the same regardless of the selected sequence. This is particularly useful when working with sequences written by others who are not using the same hardware. When a sequence is imported, it will prompt the user to substitute the local hardware configuration instead of using the exported hardware information. Initial system setup is simple as hardware configurations can be imported from the hardware steps folder.<br \/>\nSystem calibration is also simplified, with the table view expanded to show more default channels. Using existing sequences is simple, as the new system calibration features a simple re-linking dialog for assigning new channels and importing existing ones. The main calibration editor also<\/p>\n<div id=\"attachment_2462\" style=\"width: 298px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC11_Hardware_and_Calibration.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2462\" class=\"size-full wp-image-2462 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC11_Hardware_and_Calibration.jpg\" alt=\"Global Hardware Setup\" width=\"288\" height=\"148\" \/><\/a><p id=\"caption-attachment-2462\" class=\"wp-caption-text\">Global Hardware Setup<\/p><\/div>\n<p>allows the user to import calibrated device files and even entire .cal setups from older SoundCheck versions. The sequence editor is simplified since there is no need to select hardware and calibration steps.<\/p>\n<p><strong>Memory List Sorting and Grouping<\/strong><\/p>\n<p>The grouping and sorting capability introduced in version 10 has been improved for ease of use. Data may be sorted by name (alphabetically) or by order (order in which generated by sequence) and it may be auto-grouped by category or step. These settings, which can be toggled on and off, are continuously applied to all data in the memory list, so when data is added it is automatically sorted into the correct place. User-groups can also be created; these enable the user to pull out any data into a custom named group. In addition, the main menu has changed to a more intuitive function-based menu to simplify usage and avoid long drop down lists.<\/p>\n<p><strong>Virtual instruments in acquisition<\/strong><\/p>\n<p>Multiple Virtual Instruments can be opened simultaneously in the acquisition step for automation. The former drop down menu containing various VI combinations is replaced with a single choice named virtual instruments. This displays a table showing all the virtual instruments in that step. Selecting the appropriate row opens the instrument so that the settings can be checked or changed, and additional VIs can easily be added by right clicking. Virtual instrument configuration files can be loaded into the acquisition step for quick setup in any sequence.<\/p>\n<div id=\"attachment_2461\" style=\"width: 277px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC11_Analysis_Batch_Processing.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2461\" class=\"size-medium wp-image-2461 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC11_Analysis_Batch_Processing-267x300.jpg\" alt=\"Waveform Batch Processing\" width=\"267\" height=\"300\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC11_Analysis_Batch_Processing-267x300.jpg 267w, https:\/\/www.listeninc.com\/wp\/media\/SC11_Analysis_Batch_Processing.jpg 288w\" sizes=\"(max-width: 267px) 100vw, 267px\" \/><\/a><p id=\"caption-attachment-2461\" class=\"wp-caption-text\">Waveform Batch Processing<\/p><\/div>\n<p><strong>Waveform Batch Processing<\/strong><\/p>\n<p>Waveform batch analysis is powerful option that enables a group of waveforms to be analyzed with just one step in a sequence, rather than having to program multiple analysis steps. This significantly simplifies sequences with multichannel acquisition. The feature is also available in offline mode where multiple waveforms can be grouped together in a custom group and the batch analysis operand applied to all simultaneously. Such offline analysis may be useful for detailed analysis of production line data. To help distinguish the output curves and values, the name of the response waveform can optionally be appended to the resulting data via a new option to \u201cAdd Input Data Name\u201d.<\/p>\n<p><strong>Stimulus Frequency Variable<\/strong><\/p>\n<p>The Stimulus Frequency Variable feature enables a sequence to be programmed such that the start and stop frequencies can be read from a memory list value. This customer-requested feature offers additional test flexibility as the stimulus frequency may be entered from a prompt in the sequence, automatically generated, or even automatically incremented. This is particularly useful in an R&amp;D environment where one may want to program a sequence to use a different test frequency range each time during experimentation, or automatically increment the stimulus frequency and perform sequential measurements at different frequencies, for example for testing Max SPL.<\/p>\n<p><strong>Active Speech Level (Optional module p\/n 2033)<\/strong><\/p>\n<p>Active Speech Level is a post processing operation that, for a speech signal, evaluates levels for only the parts of the waveform where speech is actually present and ignores the parts where there is silence. It is widely used in telephony applications. The algorithm applied is described in ITU-T P.56 (05\/93) Method B.<\/p>\n<div id=\"attachment_2464\" style=\"width: 298px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC11_Stimulus_Frequency_from_Mem-list.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2464\" class=\"size-full wp-image-2464 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC11_Stimulus_Frequency_from_Mem-list.jpg\" alt=\"New Stimulus Frequency Variable Feature\" width=\"288\" height=\"210\" \/><\/a><p id=\"caption-attachment-2464\" class=\"wp-caption-text\">New Stimulus Frequency Variable Feature<\/p><\/div>\n<p><strong>CLEAR Algorithm with Log TSR<\/strong><\/p>\n<p>The CLEAR algorithm for perceptual measurement of Rub &amp; Buzz now works with a continuous sine sweep stimulus and Log TSR analysis. Log TSR is widely used for production line testing due to its speed and noise immunity; this development means that the perceptual Rub &amp; Buzz analysis can be carried out at the same time as the other analysis functions e.g. Frequency response, THD, polarity, impedance, etc.<\/p>\n<\/div><\/section><br \/>\n<div  class='hr av-4lio4-2997f8cddd843d6d244501a7ccbca44b hr-default  avia-builder-el-68  el_after_av_textblock  el_before_av_textblock '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n<section  class='av_textblock_section av-b4cch0-4917587a4939eead722e228bde6f3c64 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>SoundCheck New Features Version 10<\/h3>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-xwos4-34ecf3db6e06c0ebeb1a7b9c9f5ee5ed '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><em><strong>SoundCheck\u00ae 10.1<\/strong><\/em><\/p>\n<div id=\"attachment_2466\" style=\"width: 298px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC10_standard_waveform_filter.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2466\" class=\"size-full wp-image-2466 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC10_standard_waveform_filter.jpg\" alt=\"Standard Waveform Filter\" width=\"288\" height=\"151\" \/><\/a><p id=\"caption-attachment-2466\" class=\"wp-caption-text\">Standard Waveform Filter<\/p><\/div>\n<p><strong>Standard Waveform Filter<\/strong><\/p>\n<p>In addition to the Arbitrary waveform filters (introduced in SoundCheck 10.0), a selection of Standard Waveform filters are now also available, including Butterworth high-pass, low-pass, band-pass and band-stop filters. These standard filters are useful for conditioning stimulus and response waveforms when you are making time domain measurements, or for band pass analysis in the time domain (e.g. speech intelligibility or attack and release testing). The arbitrary filters are often used for telephony and hearing aid applications and can also be used when you need to listen to the processed time signal for subjective evaluation. Both the Arbitrary and Standard waveform filters require SoundCheck module 2032: Waveform Filter.<\/p>\n<div id=\"attachment_2465\" style=\"width: 298px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC10_RTA_analysis_algorithm.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2465\" class=\"size-full wp-image-2465 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC10_RTA_analysis_algorithm.jpg\" alt=\"RTA Analysis Algorithm\" width=\"288\" height=\"160\" \/><\/a><p id=\"caption-attachment-2465\" class=\"wp-caption-text\">RTA Analysis Algorithm<\/p><\/div>\n<p><strong>RTA Analysis Algorithm<\/strong><\/p>\n<p>In addition to calculating the RTA spectrum of the response waveform, the RTA analysis algorithm now allows the option to calculate the spectrum of the stimulus as well as the overall frequency response (comparing the response to the stimulus). This is useful when analyzing non-stationary signals, for example speech signals in telephony where compensation needs to be made for a non-flat stimulus.<\/p>\n<p><strong>Memory List Search<\/strong><\/p>\n<p>The memory list now has a search function (shortcut key Ctrl+F) feature to find and highlight all items which match a search string. Advanced searching through the use of regular expressions is also possible as described in the context sensitive help window of the search string. This is particularly useful when the memory list contains a large number of curves such as in production line applications.<\/p>\n<p><strong>Zwicker Loudness Spectrum<\/strong><\/p>\n<p>The Zwicker Loudness feature (introduced in SoundCheck 10.0) has been extended with a new option to output the Loudness Spectrum to the Memory List. The units for the X-axis are selectable between Hz and Bark scale. The loudness spectrum allows the user to determine which frequencies are responsible for the loudness, and is useful for analysis of telephone ring tones.<\/p>\n<div id=\"attachment_2467\" style=\"width: 298px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC10_Zwicker_Loudness.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2467\" class=\"size-full wp-image-2467 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC10_Zwicker_Loudness.jpg\" alt=\"Zwicker Loudness Spectrum\" width=\"288\" height=\"155\" \/><\/a><p id=\"caption-attachment-2467\" class=\"wp-caption-text\">Zwicker Loudness Spectrum<\/p><\/div>\n<p><strong>Serial Number or Annotation in Memory List<\/strong><\/p>\n<p>The\u2019 Protect\u2019 and \u2018Autoprotect\u2019 features in the Memory List now append the serial number to the protected curve name. This offers a quick and easy way to annotate data by typing a comment into the serial number field.<\/p>\n<p><strong>Show Memory List on Opening Sequence<\/strong><\/p>\n<p>The sequence configuration dialog has a new feature which will show the memory list when the sequence is opened. This is convenient and useful for debugging sequences.<\/p>\n<p><strong>Improved CLEAR (Perceptual Rub &amp; Buzz) Algorithm<\/strong><\/p>\n<p>Minor upgrades to the CLEAR Perceptual Rub &amp; Buzz algorithm offer a lower variance and therefore less susceptibility to noise.<\/p>\n<p><strong>More Flexible Attack and Release Algorithm<\/strong><\/p>\n<p>The filtering steps in the Attack and Release algorithm (used for measurement of automatic gain control in telephony and hearing aids) have been separated out from the algorithm so that they may be user-defined. This offers more control to the user and increases the range of applications.<\/p>\n<p><strong>Improved Support for ASIO<\/strong><\/p>\n<p>LynxTwo ASIO driver now works on Windows XP, Windows 7-32, and Windows 7-64. CardDeluxe ASIO driver now works on Windows 7-32 bit. It does not yet work on Windows 7-64.<\/p>\n<p><em><strong>SoundCheck\u00ae 10.0<\/strong><\/em><\/p>\n<p><strong>Better Data Organization with Memory List Grouping<\/strong><\/p>\n<p>The memory list, which functions as SoundCheck\u2019s database of curves, values, waveforms and results, can now be organized into custom named folders. This enables grouping by step type (e.g. all calibration curves in one sub-folder), sequence order, name, or any other custom folder structure. The Windows Explorer-like tree can be expanded and hidden at any time and full functionality is available via a contextual right click menu. In addition, curves can be dragged and dropped onto graphs, values can be dragged onto tables, etc.<\/p>\n<div id=\"attachment_2470\" style=\"width: 298px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC10_multiple_vi.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2470\" class=\"size-full wp-image-2470 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC10_multiple_vi.jpg\" alt=\"Multiple Virtual Instruments\" width=\"288\" height=\"212\" \/><\/a><p id=\"caption-attachment-2470\" class=\"wp-caption-text\">Multiple Virtual Instruments<\/p><\/div>\n<p><strong>Multiple Virtual Instruments<\/strong><\/p>\n<p>Now many instances of the same virtual instrument may be opened at once. This means that for multi-channel applications, a new instance of the VI can be opened for each channel. It also enables both the spectrum analyzer and the RTA to simultaneously be viewed while running a sequence so real time live data can be viewed. By using two signal generators, signals can be mixed (e.g. pink noise and a sine sweep) for signal conditioning. Waveforms in the memory list may also now be played directly from the Signal Generator VI.<\/p>\n<p><strong>RTA Algorithm in Analysis Step (included with RTA VI optional module)<\/strong><\/p>\n<p>The RTA Algorithm, now available in the analysis step, applies the RTA filter bank on the selected response waveform and yields the average 1\/n octave spectrum in the memory list. The advantage of this method over the RTA virtual instrument is that the analysis is perfectly synchronized with the stimulus, and the averaging time fits exactly to the length of the waveform. This eliminates the need for several stimulus repetitions and reduces the total test time. This function can also be used for multichannel acquisitions, giving the capability to use RTA analysis on multiple waveforms nearly simultaneously.\u00a0This algorithm yields the exact same response spectrum measured with the RTA virtual instrument, and it conforms to the ANSI S1.11 &#8211; 2004 class 0 standard.<\/p>\n<p><strong>ASIO Driver Support<\/strong><\/p>\n<p>ASIO drivers generally offer excellent soundcard control, and ASIO support opens up a much wider range of professional audio and multichannel sound cards.<\/p>\n<div id=\"attachment_2468\" style=\"width: 298px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC10_capture_-CSS.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2468\" class=\"size-full wp-image-2468 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC10_capture_-CSS.jpg\" alt=\"New Stimulus Analyze \/ Ignore Function\" width=\"288\" height=\"240\" \/><\/a><p id=\"caption-attachment-2468\" class=\"wp-caption-text\">New Stimulus Analyze \/ Ignore Function<\/p><\/div>\n<p><strong>Stimulus Analyze\/Ignore Option<\/strong><\/p>\n<p>The new \u2018Analyze\u2019 option in the stimulus editor allows the user to choose whether or not sections of the stimulus will be analyzed or ignored by an analysis step. This feature is particularly useful for telephony testing and for other devices that need to be conditioned before achieving a stable measurement. For example, the first section of the stimulus will contain a conditioning signal (like artificial speech) that will open the Voice Activity Detector. A second section will be the sine-based test signal to analyze (e.g. multitone or sine sweep). The Stimulus-Analyze option will tell the analysis step to process only the test signal and ignore the conditioning signal.<\/p>\n<p><strong>Zwicker Loudness (optional module)<\/strong><\/p>\n<p>Zwicker Loudness calculates the overall perceived loudness of a sound. This new post-processing operation uses a psycho-acoustic model which takes into account the nonlinearity of the human ear to sound at different frequencies and levels. It provides the capability to measure the perceived loudness of complex sounds, e.g. telephone ring tones.<\/p>\n<div id=\"attachment_2472\" style=\"width: 298px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC10_zwicker-loudness.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2472\" class=\"size-full wp-image-2472 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC10_zwicker-loudness.jpg\" alt=\"Zwicker Loudness Measurement in SoundCheck 10\" width=\"288\" height=\"137\" \/><\/a><p id=\"caption-attachment-2472\" class=\"wp-caption-text\">Zwicker Loudness Measurement in SoundCheck 10<\/p><\/div>\n<p><strong>Time Domain Waveform Filters (optional module)<\/strong><\/p>\n<p>The new Waveform Filter post-processing operation allows the user to choose a curve from the memory list, use it as the frequency response and apply it to a waveform in the memory list. The result is a new waveform that has its spectral content shaped by the selected curve. There is also an option for minimum phase and inverting the curve. This may be used, for example, for measuring the A-weighted peak acoustic pressure of a waveform. The A-weighting curve is first applied to the acoustic waveform via the waveform filtering post processing step, and then the peak value of the resulting waveform is measured. This method is used in the IEEE 269 and TIA 920 telephony standards.<\/p>\n<div id=\"attachment_2471\" style=\"width: 298px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC10_waveform-filtering.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2471\" class=\"size-full wp-image-2471 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC10_waveform-filtering.jpg\" alt=\"Time Domain Waveform Filters\" width=\"288\" height=\"142\" \/><\/a><p id=\"caption-attachment-2471\" class=\"wp-caption-text\">Time Domain Waveform Filters<\/p><\/div>\n<p><strong>Quick Polarity Test<\/strong><\/p>\n<p>A polarity test is often used to verify that a device is wired correctly. The quick polarity test is performed in an analysis step, and uses the impulse response from the Auto Delay function. It analyzes the peak of this impulse response and measures if it is negative or positive to determine overall polarity. It is a simple and easy alternative to phase domain testing for simple devices or single drivers where the phase does not change more than 180 degrees. Polarity measurement using phase response is still available as an alternative method for more complex devices<\/p>\n<\/div><\/section><br \/>\n<div  class='hr av-7r2k9g-6a2255bf0c5c1c2b958d650700077b9b hr-default  avia-builder-el-71  el_after_av_textblock  el_before_av_textblock '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n<section  class='av_textblock_section av-68gwdg-15c10e47582b8ce458f06286f9ca13f5 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>SoundCheck New Features Version 9<\/h3>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-3rqo38-46e23bdf944f71a8e3413c587f5a54ec '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><em><strong>SoundCheck\u00ae 9.1 New Features<\/strong><\/em><\/p>\n<div id=\"attachment_2479\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC9-1_PRB_screenshot.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2479\" class=\"wp-image-2479 size-medium alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC9-1_PRB_screenshot-300x136.jpg\" alt=\"New CLEAR Algortihm for Perceptual Rub &amp; Buzz Measurement\" width=\"300\" height=\"136\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC9-1_PRB_screenshot-300x136.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/SC9-1_PRB_screenshot.jpg 432w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-2479\" class=\"wp-caption-text\">New CLEAR Algorithm for Perceptual Rub &amp; Buzz Measurement<\/p><\/div>\n<p><strong>NEW CLEAR Perceptual Distortion Algorithm for Rub &amp; Buzz Measurement<\/strong><br \/>\nSoundCheck 9.1 introduces Listen\u2019s new CLEAR (Cepstral Loudness Enhanced Algorithm for Rub &amp; Buzz) algorithm for perceptual Rub &amp; Buzz analysis. This new algorithm uses a simplified auditory perceptual model to measure the perceived loudness of the Rub &amp; Buzz distortion in phons rather than the more traditional dB SPL and % distortion units. This model better identifies whether distortion due to manufacturing defects can be heard by the listener than conventional measurements. In addition to a result which corresponds more accurately to the human ear, this new test method also offers significant advantages for use on the production line. It is less sensitive to transient background noises than traditional methods, therefore is reliable in noisy environments. In addition, it is easier to set up. Since it analyzes all harmonics, the user does not have to select the harmonics to be analyzed, and limit setting is simpler as a flat line can be used regardless of frequency and level (rather than measurement relative to a reference standard as is necessary with conventional distortion measurements). Full details of the research leading to the development of this algorithm are given in the paper \u2018Practical Measurement of Loudspeaker Distortion Using a Simplified Auditory Perceptual Model\u2019.<\/p>\n<p><strong>Refined RTA<\/strong><br \/>\nThe RTA has been re-designed to offer improved performance. The filters have been improved and fully tested for compliance with ANSI S1.11-2004, and the averaging time is more accurate. In addition, it is also now compatible with NI cards.<\/p>\n<p><strong>Device Selection<\/strong><br \/>\nA device can now be selected in the hardware editor using its device ID rather than its name. This is useful for testing USB and Bluetooth devices where Windows software automatically changes the device name each time it is connected. Using the device ID instead of the name simplifies automation of tests for production line use.<\/p>\n<p><strong>NIDAQmx drivers<\/strong><br \/>\nDigital I\/O cards with NIDAQmx drivers are now supported.<\/p>\n<p><strong>Windows 7 Compatibility<\/strong><br \/>\nSoundCheck 9.1 has been fully tested for compatibility with both the 32 bit and 64 bit versions of Windows 7. Please consult Listen for Windows 7 Soundcard compatibility.<\/p>\n<p><strong>Hardware Key Number Display<\/strong><br \/>\nThe hardware key number is now displayed on the main panel. This facilitates vendor inspection of test software.<\/p>\n<p>Perceptual Rub &amp; Buzz using new CLEAR\u2122 algorithm shows audible distortion more clearly. Traditional Rub &amp; Buzz measurements do not take into account the insensitivity of the human ear to low and high frequencies, therefore making it more difficult to identify problem areas and set limits on a production line. This speaker clearly shows audible distortion below resonance (&lt;100 Hz) and at cone breakup (750 Hz). Both curves are shown on a 60 dB scale for easier comparison even though the units are different (Perceptual distortion in Phons and traditional distortion in %).<\/p>\n<p><em><strong>SoundCheck\u00ae 9.0 New Features<\/strong><\/em><br \/>\n<em> SoundCheck\u00ae 9.0 offers a host of new features designed to offer ease of use, increased measurement accuracy, and simpler analysis and presentation of data.<\/em><\/p>\n<div id=\"attachment_2475\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC9_AmpConnect-Custom-step.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2475\" class=\"size-medium wp-image-2475 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC9_AmpConnect-Custom-step-300x79.jpg\" alt=\"AmpConnect Panel Within SoundCheck\" width=\"300\" height=\"79\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC9_AmpConnect-Custom-step-300x79.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/SC9_AmpConnect-Custom-step-705x185.jpg 705w, https:\/\/www.listeninc.com\/wp\/media\/SC9_AmpConnect-Custom-step-450x118.jpg 450w, https:\/\/www.listeninc.com\/wp\/media\/SC9_AmpConnect-Custom-step.jpg 978w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-2475\" class=\"wp-caption-text\">AmpConnect Panel Within SoundCheck<\/p><\/div>\n<p><strong>AmpConnectTM Support<\/strong><br \/>\nSoundCheck\u00ae 9.0 supports AmpConnectTM, Listen\u2019s new integrated hardware box which replaces a power amplifier, microphone power supply, impedance box and digital I\/O card in your testing setup. AmpConnect can be fully controlled either via the sequence editor, or directly via a control panel that replicates the appearance of the front of the hardware.<\/p>\n<p><strong>SoundCheck ONETM<\/strong><br \/>\nSoundCheck ONETM, the low cost production test version of SoundCheck 9.0 consists of SoundCheck ONE software bundled with AmpConnect. Anyone who purchases \/ upgrades to SoundCheck 9 and purchases an AmpConnect within 6 months will have their SoundCheck 9.0 key programmed to also work in SoundCheck ONE mode. This enables the user to switch between SoundCheck 9.0 and SoundCheck ONE, so that sequences for SoundCheck ONE can be written without purchasing another system.<\/p>\n<div id=\"attachment_2477\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC9_LP.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2477\" class=\"size-medium wp-image-2477 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC9_LP-300x135.jpg\" alt=\"New Loose Particle Algorithm\" width=\"300\" height=\"135\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC9_LP-300x135.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/SC9_LP-705x316.jpg 705w, https:\/\/www.listeninc.com\/wp\/media\/SC9_LP-450x202.jpg 450w, https:\/\/www.listeninc.com\/wp\/media\/SC9_LP.jpg 881w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-2477\" class=\"wp-caption-text\">New Loose Particle Algorithm<\/p><\/div>\n<p><strong>Loose Particle Algorithm<\/strong><br \/>\nThe improved Loose Particle Algorithm offers better noise immunity in production and other noisy environments as limits float with the normalized background noise rather than being set absolutely. In addition to simplifying limit setting, false rejections due to sudden increases in background noise are less likely. There is now also a setting for choosing a maximum stimulus frequency, above which the loose particle envelope is not calculated. As loose particles tend to present themselves during the low frequency portion of a stimulus sweep, this feature further prevents false rejects.<\/p>\n<p><strong>Curve Smoothing<\/strong><br \/>\nCurve smoothing with Nth octave resolution is now built into the analysis editor. Many measurements require the collection of large volumes of data, particularly at high frequencies where constant bandwidth analysis functions such as FFT and Log TSR are used. While such data quantities are essential for certain measurements, reducing the volume of data using curve smoothing offers three advantages:<\/p>\n<ul>\n<li>\n<div id=\"attachment_2474\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC9_12th_Smoothing.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2474\" class=\"size-medium wp-image-2474 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC9_12th_Smoothing-300x103.jpg\" alt=\"NEw Curve Smoothing Functionality\" width=\"300\" height=\"103\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC9_12th_Smoothing-300x103.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/SC9_12th_Smoothing-705x242.jpg 705w, https:\/\/www.listeninc.com\/wp\/media\/SC9_12th_Smoothing-450x155.jpg 450w, https:\/\/www.listeninc.com\/wp\/media\/SC9_12th_Smoothing.jpg 771w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-2474\" class=\"wp-caption-text\">NEw Curve Smoothing Functionality<\/p><\/div><\/p>\n<p>since the number of data points is reduced, post-processing is faster, thus reducing the overall test time<\/li>\n<li>data can be reduced to a common resolution to easily compare different algorithms<\/li>\n<li>it produces smoother curves which looks good on data sheets and marketing materials.<\/li>\n<\/ul>\n<p>This feature is available in the Time Selective Response, Spectrum, Transfer Function, and Multitone analysis types.<\/p>\n<p><strong>TSR Algorithm Maximum Harmonic Indicator<\/strong><br \/>\nLog TSR sweeps are a popular test method, but inexperienced users may inadvertently miss important measurement details by sweeping too fast. For example, a given combination of window size and speed may be adequate for measuring Rub &amp; Buzz, but insufficient to enable analysis of individual harmonics. The new indicator shows the maximum harmonic that can be selected independently of its neighbors. The indicator, while it does not place any restrictions on the user\u2019s ability to define the speed and window size, will offer an advisory when the settings are such that individual harmonics will not be accurately calculated.<\/p>\n<div id=\"attachment_2478\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.listeninc.com\/wp\/media\/SC9_stimulus_editor.jpg\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2478\" class=\"size-medium wp-image-2478 alignright\" src=\"https:\/\/www.listeninc.com\/wp\/media\/SC9_stimulus_editor-300x250.jpg\" alt=\"Advanced View for Stimulus Editor\" width=\"300\" height=\"250\" srcset=\"https:\/\/www.listeninc.com\/wp\/media\/SC9_stimulus_editor-300x250.jpg 300w, https:\/\/www.listeninc.com\/wp\/media\/SC9_stimulus_editor-705x588.jpg 705w, https:\/\/www.listeninc.com\/wp\/media\/SC9_stimulus_editor-450x375.jpg 450w, https:\/\/www.listeninc.com\/wp\/media\/SC9_stimulus_editor.jpg 718w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-2478\" class=\"wp-caption-text\">Advanced View for Stimulus Editor<\/p><\/div>\n<p><strong>Choice of Impedance Measurement Method<\/strong><br \/>\nSoundCheck\u00ae 9.0 supports the measurement of impedance using a resistor before the load (as used in AmpConnect) or after the load (as when using a Listen impedance box).<\/p>\n<p><strong>Advanced View for Stimulus Editor and Limits Editor<\/strong><br \/>\nBoth the Stimulus and Limits Editor menus now offer two views, basic and advanced. The basic views feature only the commonly adjusted settings, and by clicking on the advanced tab, many more are revealed. This keeps the software simple for novice and production line users while retaining the flexibility demanded by R&amp;D applications.<\/p>\n<p><strong>Option to Switch to Demo Mode<\/strong><br \/>\nSoundCheck can now be switched to Demo Mode without the need for a new hardware key. Running in demo mode will randomize data, but will allow the user to view and experiment with all modules and analysis algorithms prior to purchasing them. Users have the choice of launching the full version of SoundCheck or SoundCheck ONE in demo mode.<\/p>\n<p><strong>Simultaneously open multiple DAT Files<\/strong><br \/>\nSeveral DAT files can now be opened at once from the Memory List. This is convenient when running statistics on a batch of curves and working with large numbers of files<\/p>\n<\/div><\/section><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-24sr78-27371737125793a0c768cf84e2ea760b\">\n#top .hr.hr-invisible.av-24sr78-27371737125793a0c768cf84e2ea760b{\nheight:25px;\n}\n<\/style>\n<div  class='hr av-24sr78-27371737125793a0c768cf84e2ea760b hr-invisible  avia-builder-el-74  el_after_av_textblock  avia-builder-el-last '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><\/p><\/div>\n<div  class='flex_column av-2oya10-01cf952585c4e1ec8fc0bc768b407422 av_one_full  avia-builder-el-75  el_after_av_one_full  el_before_av_one_full  first flex_column_div  column-top-margin'     ><section  class='av_textblock_section av-mhwi8anj-7353e2f2dfadf390f235cf3f2d947c0e '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>Explore SoundCheck&#8217;s features:<\/h3>\n<p><a href=\"https:\/\/www.listeninc.com\/products\/soundcheck-software\/soundcheck-for-rd-labs\/\">For R&amp;D<\/a>\u00a0 |\u00a0\u00a0<a href=\"https:\/\/www.listeninc.com\/products\/soundcheck-overview\/soundcheck-for-production\/\">For Production<\/a>\u00a0 |\u00a0 <a href=\"https:\/\/www.listeninc.com\/products\/soundcheck-software\/soundcheck-features-and-functionality\/soundcheck-integration\/\">Integration<\/a>\u00a0 |\u00a0\u00a0<a href=\"https:\/\/www.listeninc.com\/products\/soundcheck-overview\/making-measurements\/\">Making Measurements<\/a>\u00a0 |\u00a0\u00a0<a href=\"https:\/\/www.listeninc.com\/products\/soundcheck-software\/soundcheck-features-and-functionality\/soundcheck-algorithm-highlights\/\">Algorithm Highlights<\/a>\u00a0 |\u00a0\u00a0<a href=\"https:\/\/www.listeninc.com\/products\/soundcheck-overview\/new-features-by-version\/\">What&#8217;s New<\/a>\u00a0 |\u00a0\u00a0<a href=\"https:\/\/www.listeninc.com\/products\/soundcheck-software\/specs\/soundcheck-packages-and-modules\/\">Packages, Modules &amp; Pricing<\/a><\/p>\n<\/div><\/section><\/div>\n<div  class='flex_column av-av_one_full-048119fdb636ea3d70edc0b975509c6c av_one_full  avia-builder-el-77  el_after_av_one_full  avia-builder-el-last  first flex_column_div  column-top-margin'     ><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":6,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-3591","page","type-page","status-publish","hentry"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.listeninc.com\/zh-hans\/wp-json\/wp\/v2\/pages\/3591\/"}],"collection":[{"href":"https:\/\/www.listeninc.com\/zh-hans\/wp-json\/wp\/v2\/pages\/"}],"about":[{"href":"https:\/\/www.listeninc.com\/zh-hans\/wp-json\/wp\/v2\/types\/page\/"}],"author":[{"embeddable":true,"href":"https:\/\/www.listeninc.com\/zh-hans\/wp-json\/wp\/v2\/users\/3\/"}],"replies":[{"embeddable":true,"href":"https:\/\/www.listeninc.com\/zh-hans\/wp-json\/wp\/v2\/comments\/?post=3591"}],"version-history":[{"count":77,"href":"https:\/\/www.listeninc.com\/zh-hans\/wp-json\/wp\/v2\/pages\/3591\/revisions\/"}],"predecessor-version":[{"id":23113,"href":"https:\/\/www.listeninc.com\/zh-hans\/wp-json\/wp\/v2\/pages\/3591\/revisions\/23113\/"}],"wp:attachment":[{"href":"https:\/\/www.listeninc.com\/zh-hans\/wp-json\/wp\/v2\/media\/?parent=3591"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}