技术资料
拥有超过100年的音频测量经验,我们的团队已经创建了丰富的技术论文,程序,文献以及其他有用的信息来协助您与您的测试需求。请浏览下面的系列收集,或按照资源类型过滤。
Filter By Category
Impedance Measurement – Dual Channel Method Using Math Post-Processing
/在: Free, Free Loudspeaker Sequences, Free Loudspeaker Sequences/通过: Zarina
This sequence demonstrates an alternative to the traditional SoundCheck single channel impedance measurement method. A stepped sine sweep from 20 Hz to 20 kHz is played through the speaker while the signal across the loudspeaker terminals is recorded by Direct In 1 and the signal across the sense resistor (impedance box) is recorded by Direct In 2. A heterodyne analysis step is then applied to calculate the fundamental response from both inputs and a math post-processing step divides Fundamental A (speaker terminal voltage) by Fundamental B (voltage across sense resistor). A post-processing step corrects for the value of the reference resistor before displaying the final impedance curve. The curve is then post-processed to calculate resonance frequency, maximum impedance and Q of the resonance peak. A set of arbitrary limits steps are also provided to generate pass/fail results.
Perceptual Rub & Buzz
/在: Free, Free Loudspeaker Sequences, Free Loudspeaker Sequences/通过: Zarina
This sequence uses the CLEAR algorithm for perceptual Rub & Buzz measurement to detect AUDIBLE Rub & Buzz. It uses a simplified auditory perceptual model to measure the loudness of Rub & Buzz distortion in phons rather than the more traditional dB SPL and % distortion units. These better identify whether distortion due to manufacturing defects can be heard by the listener than conventional measurements. In addition to a result which corresponds more accurately to the human ear, this new test method also offers two significant advantages for use on the production line. It is less sensitive to transient background noises than traditional methods, therefore is reliable in noisy environments, and it is much simpler to set limits than when using conventional distortion measurements. The sequence includes saved data that can be loaded from disk, so even if you don’t have a speaker handy you can still listen to the wav. file and see how SoundCheck displays the data.
Impedance Measurement – Dual Channel Method Using Transfer Function
/在: Free, Free Loudspeaker Sequences, Free Loudspeaker Sequences/通过: radarThis sequence demonstrates an alternative to the traditional SoundCheck single channel impedance measurement method. A pink noise stimulus (10Hz – 10kHz) is played through the speaker while the signal across the amplifier terminals is recorded by Direct In 1 and the signal across the sense resistor is recorded by Direct In 2. A transfer function analysis step is then applied to the recorded time waveforms to calculate the impedance curve. The curve is then post-processed to calculate resonance frequency, maximum impedance and Q of the resonance peak. A set of arbitrary limits steps are also provided to generate pass/fail results. The final display shows the impedance curve and a results window.
Harmonic Distortion Measurement: The effects of sampling rate and stimulus frequency on the measured harmonic frequency (including THD and Rub & Buzz)
/在: Algorithm Technical Notes, Measurement Techniques and Guidelines Technical Notes, Technical Notes/通过: ZarinaAuthor: Steve Temme
Harmonic distortion measurements can be confusing to interpret, and it’s important to understand the data that you are looking at, particularly the relationship between the stimulus frequency and the measured harmonic frequency. This brief guide explains the relationships between sampling rate, stimulus frequency and measured harmonics for both normalized and conventional harmonic distortion measurements.
Practical Impedance Measurement
/在: Algorithm Technical Notes, Loudspeaker Technical Notes, Technical Notes/通过: Zarina
Author: Steve Temme
Loudspeaker impedance measurements are made for many reasons. In the R&D lab, these range from the simple task of identifying a speaker’s resonant frequency to more complex functions such as calculating the speaker’s Thiele-Small parameters. On the production line, impedance measurement is a key quality control parameter that verifies that the speaker’s motor properties are correct, that the magnet is charged correctly, the voice coil number of turns is correct and that the moving mass (cone and voice coil) is within specification.
There are two basic methods of making impedance measurements on loudspeakers, micro-speakers and headphones using sound card and software based systems. These are basic single channel measurements, and more complex, but more accurate, dual channel methods. Both methods are implemented in SoundCheck, and with some additional hardware these tests are simple to carry out.
Advances in Impedance Measurement of Loudspeakers and Headphones
/在: Algorithm Papers, Loudspeaker Papers, Papers/通过: Zarina
Impedance measurement is often the sole electrical measurement in a battery of QC tests on loudspeakers and headphones. Two test methods are commonly used, single channel and dual channel. Dual Channel measurement offers greater accuracy as both the voltage across the speaker (or headphone) and the reference resistor are measured to calculate the impedance. Single Channel measurement methods are more commonly used on the production line because they only require one channel of a stereo soundcard, which leaves the other free for simultaneous acoustic
tests. They are less accurate, however, due to the test methods making assumptions of constant voltage or constant current. In this paper we discuss a novel electrical circuit that offers similar impedance measurement accuracy compared to complex dual channel measurement methods but using just one channel. This is expected to become popular for high throughput production line measurements where only one channel is available as the second channel of the typical soundcard is being used for simultaneous acoustic tests.
Authors: Steve Temme and Tony Scott
Presented at the 135th AES Conference, New York 2013
Measurement of Harmonic Distortion Audibility Using A Simplified Psychoacoustic Model – Updated
/在: Algorithm Papers, Distortion Papers, Papers/通过: Zarina
A perceptual method is proposed for measuring harmonic distortion audibility. This method is similar to the CLEAR (Cepstral Loudness Enhanced Algorithm for Rub & buzz) algorithm previously proposed by the authors as a means of detecting audible Rub & Buzz which is an extreme type of distortion[1,2]. Both methods are based on the Perceptual Evaluation of Audio Quality (PEAQ) standard[3]. In the present work, in order to estimate the audibility of regular harmonic distortion, additional psychoacoustic variables are added to the CLEAR algorithm. These variables are then combined using an artificial neural network approach to derive a metric that is indicative of the overall audible harmonic distortion. Experimental results on headphones are presented to justify the accuracy of the model.
Authors: Steve Temme, Pascal Brunet and Parastoo Qarabaqi
Presented at the 51st AES Conference, Helsinki, Finland, 2013
Audio Test Stimuli – An Overview
/在: Measurement Techniques and Guidelines Technical Notes, Technical Notes/通过: ZarinaAuthor: Steve Temme
Most audio analysis systems offer a wide range of stimulus option, and selecting the right one can be daunting. This overview explains the different stimulus types, what the waveforms look and sound like (click the speaker icon to hear the sound), the advantages and disadvantages of each and when you would be likely to select each one.











