Impedance Measurement – Dual Channel Method Using Transfer Function
This sequence demonstrates an alternative to the traditional SoundCheck single channel impedance measurement method. A pink noise stimulus (10Hz – 10kHz) is played through the speaker while the signal across the amplifier terminals is recorded by Direct In 1 and the signal across the sense resistor is recorded by Direct In 2. A transfer function […]