Frequency-Normalized THD Test Sequence
This sequence measures both conventional Total Harmonic Distortion (THD) and Normalized THD to provide a more accurate representation of a device’s nonlinear behavior. A stimulus is played through the device under test and recorded via a calibrated reference microphone and amplifier signal paths. Conventional THD compares each harmonic to the fundamental at the stimulus frequency, which can cause distortion results to be influenced by the device’s frequency response roll-off. Normalized THD instead compares each harmonic to the fundamental at its measured frequency before plotting the result at the stimulus frequency, removing the effect of linear response variations. Both methods can be displayed and analyzed within the same step, allowing direct comparison of traditional and normalized distortion results.





This pre-written test sequence demonstrates how to use a laser and SoundCheck to measure the peak (max and min) displacement of a loudspeaker diaphragm. SoundCheck is easily configured to include a laser signal path, making it simple to correlate diaphragm displacement with electrical impedance and audio artifacts.