A New Statistics Module is available in SoundCheck version 22 and later. SoundCheck’s statistics module is completely overhauled to make it more powerful and intuitive. A new layout makes data selection easier, and curves, values, and results can now simply be dragged and dropped from the memory list into the statistics editor. A new ‘Reset Statistics’ step allows statistics to be reset during a sequence. This is useful when applying statistical analysis to data from a sequence loop or a fixed number of measurements, as the statistics data and sample count can be automatically cleared, ready for the next measurement once the desired settings have been reached. Enhanced searching, including meta-data, makes it easy to select groups of curves from the memory list, and it is now even possible to specify a frequency range within which to run statistics.
Crest Factor Analysis is available in SoundCheck version 22 and later. Distortion options now include crest factor analysis, a technique that measures peak-to-RMS ratio to evaluate impulsive distortion and analyze the dynamic range of real signals. It complements SoundCheck’s unique enhanced Loose Particle algorithm for transient distortion measurement.
Sequence Protection is available in SoundCheck version 21 and later.
Sequence protection guards your intellectual property and adds an additional level of assurance that your tests are run as-intended by your production facility or contract manufacturer. Any test sequence can now be locked and password-protected before distribution. Once in a locked state, it can be run, but sequence steps and limits cannot be edited without the password. Furthermore, the sequence steps cannot even be viewed, protecting the intellectual property in your sequences.
Sequences can also be configured to only run on a particular SoundCheck system, or block of systems. This further protects against unauthorized use and helps ensure the end-to-end integrity of your tests when working with contract manufacturers, guaranteeing that your products are tested exactly as you planned.
Watch the video demo of Sequence Protection in SoundCheck
Sequence Versioning is available in SoundCheck version 22 and later.
Sequence versioning makes it easy to track changes made to a sequence to ensure that colleagues and contract manufacturers are using the correct version. Comment fields make it easy to document changes, and the sequence history view provides a log of historical changes. Archiving functionality allows the sequence to be backed up while it is being developed, so changes can easily be rolled back while retaining the versioning information.
Python Custom Step is an optional module, part #2042. It is available in SoundCheck version 22 and later.
The Python custom step module enables users to call custom Python functions from a SoundCheck sequence. This makes it easy to pass data and variables between SoundCheck and other devices or programs. Applications include sending custom commands to put a device into diagnostic mode or playing a test signal from a device. It also enables communication with custom databases, and passing directional measurements to programs such as VACS and EASE for balloon analysis. Users can also call MATLAB functions via Python for automated MATLAB analysis of SoundCheck measurements. This module avoids requiring LabVIEW to integrate with other programs, simplifying programming and maintenance.
Watch the video demo of the Python Custom Step module
Everyone knows SoundCheck is a versatile and flexible R&D audio test system. But did you know it’s also fast and cost-effective for production line audio measurement, and offers unrivaled integration with larger factory test environments?
End of line testing is nothing new to us. We started the global trend from human listeners and expensive hardware analyzers to software-based test systems back in 1995. Many of the measurements we introduced in the 1990s are still used today. Besides introducing newer and better measurement methods like perceptual algorithms, we’re driving the integration of audio testing within a larger factory test environment. Let’s take a look at some of the things that make SoundCheck great for end-of-line tests.
Production Line Audio Measurement with SoundCheck
Learn More About SoundCheck’s Production Line Features
Seminar Recording: External Control of SoundCheck. Detailed information about controlling SoundCheck as part of a large factory automation system.
Everyone knows SoundCheck is a versatile and flexible R&D audio test system. But did you know it’s also fast and cost-effective for production line testing, and offers unrivaled integration with larger factory test environments?
End of line testing is nothing new to us. We started the global trend from human listeners and expensive hardware analyzers to software-based test systems back in 1995. Many of the measurements we introduced in the 1990s are still used today. Besides introducing newer and better measurement methods like perceptual algorithms, we’re driving the integration of audio testing within a larger factory test environment. Let’s take a look at some of the things that make SoundCheck great for end-of-line tests.
Most importantly, SoundCheck’s fast and reliable. Every test algorithm we’ve designed has speed and noise immunity at the forefront, from our unique stepped sine wave stimulus, Stweep, and Harmonictrak analysis back in 1995 to the second generation of perceptual distortion measurements in more recent years. And all our production line measurements, use the same stimulus to ensure fast throughput with simultaneous measurement of all parameters.
Soundcheck is hardware-agnostic, and compatible with many audio interfaces from our own custom designed all-in-one hardware to off the shelf soundcards. It even supports audio over IP with Dante. It works with any brand of amplifiers, microphones, couplers and test jigs. It’s also easy to control footswitches, PLCs, barcode readers and other production line equipment through a custom step in a test sequence. This gives you total flexibility, whether you are re-using existing hardware or building a system from scratch.
Both hardware and software are modular, so you can get the production functionality you need, without paying for anything that you don’t. Although a production system is significantly cheaper than an R&D SoundCheck system, it’s still fully compatible – you can create tests on an R&D system and send them to your production systems, or bring results from your production system back into an R&D system for detailed analysis.
However, it’s the seamless integration with custom factory test systems that really differentiates SoundCheck.
Full TCP/IP control lets SoundCheck communicate on any operating system, via any TCP/IP-supportive language including python, c-sharp and Labview. TCP/IP commands can trigger a test, pass the output back to an external program, or even pull in externally stored sequence parameters such as limits and stimuli. This allows the same test sequence to be used for many different products, reducing the sequence maintenance burden.
SoundCheck is just as flexible for saving data. Standard data formats include text, csv, Excel, TDMS, Matlab and SoundCheck’s open source binary file format. There’s also a plugin for WATS Test Data Management software. You can use an autosave step in your sequence to write curves, values, results, or waveforms directly to an SQL database each time a sequence is run, and industry standard tools can then be harnessed to run analytics over large data sets. If these options aren’t enough, all the data, curves, and other items saved in SoundCheck’s memory list, can always be accessed directly via TCP/IP, so you can write your own customized program to collect exactly the SoundCheck data you need.
SoundCheck’s built-in security features provide peace of mind if you share your tests with manufacturing partners. Sequence protection locks and hides all the information in a sequence so that it can be run, but not viewed or altered. So you have confidence that your products are tested exactly how you intended. No-one can adjust the limits to achieve higher yield, and it removes the risk of your tests being modified and re-purposed for use on other product lines. To add further security and measurement confidence, a sequence can even be configured to only run on a particular SoundCheck system, or block of system hardware keys.
These features let you bring the power of SoundCheck into pretty much any large automated test platform, no matter what software and operating system it is running on. Talk to your sales engineer to learn more.
https://www.listeninc.com/wp/media/2024/01/100_things_100_thumbnail-1.png-1.png10801920Zarinahttps://www.listeninc.com/wp/media/logo.pngZarina2024-01-25 00:10:102026-08-21 13:22:35Production Line Audio Measurement With SoundCheck (100 Things #100)
Calibrating signal paths is a critical part of any audio measurement, and SoundCheck offers the ultimate flexibility for calibrating audio interfaces. Whether you need two channels or sixty-four, analog or digital, each has its own unique configuration and there is no limit on the number of channels that can be calibrated. For example, its possible to have some channels calibrated with a 6-mic array for recording a response, while others are configured to measure motor vibration and RPM speed. Not only can you mix different devices, but each channel can be calibrated using different audio drivers so it’s no problem to combine something like a Bluetooth headset with analog ear simulators and a digital wav file. Learn more in this short video.
Calibrating Audio Signal Paths
Learn More About Calibrating Signal Paths in SoundCheck
Video Script: Calibrate your Signal Paths with any audio interface
In any audio test and measurement system, your signal path begins and ends with your audio interface. Whatever software system and interface you’re using, it’s important to correctly calibrate all input and output channels to get accurate results
SoundCheck offers the ultimate flexibility for calibrating audio interfaces. Any number of channels can be calibrated, so whether you need two channels or sixty-four, each channel has its own unique configuration. This means it’s possible to have some channels calibrated with a 6-mic array for recording a response, while others are configured to measure motor vibration and RPM speed.
Not only can you mix different devices, but each channel can be calibrated using different audio drivers so it’s no big deal if you are combining something like a Bluetooth headset with analog ear simulators and a digital wav file.
This flexibility ensures your test system is future-proofed and can even calibrate hardware that doesn’t exist yet, so long as it conforms to digital audio standards. Over the years we’ve calibrated USB, Bluetooth, Dante, AVB, A2B and more, as well as the more standard types such as WDM, ASIO, Core Audio and WASAPI.
To calibrate an audio device, you need to measure both the Vp in and Vp out values as well as the latency at all the sample rates you will be using.
You can do this directly from the hardware editor itself. You’ll need an AC multimeter that’s accurate to at least 250Hz, and an adapter to insert it in the input / output chain of the audio interface during the calibration process. Should the need arise for field calibration, that can also be done using this method.
To avoid this step, when you purchase a 3rd party interface directly from Listen, we’ll determine the Vp values and the latency before it leaves our facility. All you need to do is enter the device values from the provided calibration sheet into the hardware editor, and you’re ready to start measuring.
Our own all-in-one audio test hardware takes this one step further with self-calibration. With both the 2-channel AudioConnect 2 and the 6-in, 2-out AmpConnect 621, hardware editor values are measured during manufacture and stored on the device. These values are auto-populated in the hardware editor when it’s connected via USB, so you never need to manually calibrate these devices. If you swap hardware, the calibration is automatically updated.
To learn more about calibrating signal paths in SoundCheck, check out our online knowledgebase and user manual.
https://www.listeninc.com/wp/media/2024/01/100_things_99_thumbnail.png.png10801920Zarinahttps://www.listeninc.com/wp/media/logo.pngZarina2024-01-18 00:10:552026-08-21 14:43:30Calibrating Signal Paths with Any Interface (100 Things #99)
Time Domain Waveform Filtering in SoundCheck lets you apply any filter to a signal in the time domain instead of the frequency domain. This enables you to apply a filter, such as an A-weighting filter, without affecting the peaks or crest factor of the signal. Filters can also be applied to any waveform in the memory list, such as the stimulus, response, or any intermediate waveform. Watch this short video to learn how standard and custom waveform filters are used.
Time Domain Waveform Filtering
Learn More About SoundCheck’s Advanced Features
Read on about more measurement features in SoundCheck.
Video Script: Using Time Domain Waveform Filtering in SoundCheck
Waveform filtering in SoundCheck lets you apply any filter to a signal in the time domain instead of the frequency domain. This is required when you want to apply a filter, such as an A-weighting filter, without affecting the peaks or crest factor of the signal, e.g. peak sound pressure level, A-weighted. It can also be applied to any waveform in the memory list, such as the stimulus, response, or any intermediate waveform.
Both standard and arbitrary filters are available. Standard filters include lowpass, highpass, bandpass and bandstop filters. You can select the cutoff frequencies, and control the slope of the filter using the filter order. SoundCheck’s standard filters are implemented as IIR Butterworth filters, and are ideal for most applications where you need to attenuate certain frequency ranges. For example, you can use a high-pass filter to remove some low frequency background noise or remove dc offset. Alternatively, you might use a lowpass filter to attenuate alias frequencies that could cause your amplifier to clip at very high frequencies that are not of interest.
You can also create your own arbitrary waveform filter by applying any curve from the memory list to the waveform. This can be used to apply weightings such as K-weighting for loudness or a bandpass filter to a speech stimulus. Or you can even specify your own custom weighting or equalization, for example to see what happens to a customer’s speaker when they boost the bass.
https://www.listeninc.com/wp/media/2023/12/100_things_95_thumbnail.png.png10801920Zarinahttps://www.listeninc.com/wp/media/logo.pngZarina2023-12-14 10:31:152026-08-21 13:55:39Time Domain Waveform Filtering (100 Things #95)
Group and Batch Processing is a really neat feature in SoundCheck that saves huge amounts of time when processing data. Curves, values and waveforms can be grouped and processed together, and the analysis, post processing or statistics runs almost as quickly as on a single piece of data. This can be done during a sequence, or offline with previously collected data. It even extends to imported data – for example, if you want to run a POLQA analysis on a batch of recordings made in a different system, you can simply import the wav files and calculate scores for hundreds or even thousands of waveforms all at once.
Save Time Processing Data with Group and Batch Processing
Audio test and measurement involves collecting and analyzing a lot of data. You might have multiple inputs and outputs, or you need to collect data not just once but over and over again. Perhaps you’re averaging measurements on a single unit over multiple runs, or testing multiple units in a production facility. Handling and processing all this data efficiently, in realtime, can be complex.
SoundCheck processes large groups of data quickly and easily with its group and batch processing capabilities. Curves, values and waveforms are grouped and processed together, and the analysis, post processing or statistics runs almost as quickly as on a single piece of data.
This is useful, for example, if you’re repeating a series of sequence steps on a single device, to calculate the deviation in its response at various positions, or if you’re averaging sensitivity values of a batch of 15 microphones for a spec sheet.
Groups of data can be analyzed and processed either within a test sequence or offline.
In a sequence, groups of data can be automatically created, saved in the Memory List and automatically analyzed together the same way every time the sequence is run. Here’s a simple example sequence where I capture recordings using a 6 mic array, group the recorded waveforms and use a single analysis step to get responses from each of the microphones. The same process can also be used in post processing or limit steps. SoundCheck also makes it easy to keep track of your data by allowing you to append your data names with Signal Path and Input data names.
Data processing outside of a sequence is known as “offline mode” – let’s take a look at an example. Here, I’ll group the frequency responses of 5 microphones I measured previously and calculate their sensitivity values at 1kHz in a single post processing step, rather than using 5 such steps. Note how fast it is in both cases!
SoundCheck’s batch processing capabilities even extend to imported data. For example, if you want to run a POLQA analysis on a batch of recordings made in a different system, you can simply import the wav files and calculate scores for hundreds or even thousands of waveforms all at once.
SoundCheck’s batch processing capabilities handle large amounts of data extremely fast, helping both R&D labs and production facilities to reduce test times. To learn more about SoundCheck’s extensive audio measurement toolkit, check out www.listeninc.com.
https://www.listeninc.com/wp/media/2023/11/100_things_93_thumbnail.png.png10801920Zarinahttps://www.listeninc.com/wp/media/logo.pngZarina2023-11-30 02:00:532026-08-21 15:24:50Group and Batch Processing of Data Curves (100 Things #93)
Did you know that SoundCheck was the first audio test system to implement Time Selective Response Analysis with the continuous log sweep stimulus (also known as a frequency log sweep, or Farina sweep) way back in 2001? TSR analysis allows reflections to be windowed out, making it great for loudspeaker simulated free field measurements and room acoustics measurements. It’s also valuable as a smart trigger for robust open loop measurement testing. Watch this video for a quick overview.
Continuous Log Sweep with Time Selective Response Analysis
Learn more
Read on about stimulus and analysis capabilities in SoundCheck.
Learn more about Simulated Free Field Measurements
Did you know that SoundCheck was the first audio test system to implement a continuous log sweep stimulus? We introduced it back in 2001, shortly after Angelo Farina’s landmark AES paper on the subject. Let’s take a look at how it works and how it’s used.
A continuous log sweep, sometimes known as a frequency Log sweep or Farina sweep, is a continuous sine sweep with equal time and energy in every octave. Since it sweeps slower at low frequencies but speeds up as the frequency increases, it’s a great choice for fast measurements. It differs from a conventional stepped sine stimulus, in that the continuous log sweep plays across all frequencies in the range with a defined sweep rate per decade, whereas the stepped sine sweep “steps” through different frequencies across the range.
Both stimuli can measure frequency response and harmonic distortion, but the analysis methods differ. A continuous log sweep uses a time selective response, or TSR analysis. This involves calculating an impulse response and applying a user-defined time window that can isolate or remove any reflections caused by the test environment. A stepped sine requires a HarmonicTrak analysis. Only the continuous log sweep with TSR analysis can window out reflections, allowing a simulated free field measurement even when you are not in a fully anechoic environment.
Let’s take a look. In the TSR analysis step, we’ll enable this checkbox here to output an impulse response to the memory list so we can view it. It can be displayed either on a linear or logarithmic scale. The window size at the top is where we define the start and stop points of the window that’s applied to the impulse response. We can look at this in SoundCheck to help us decide which points to use. Here, we can clearly see a large impulse that has been autodelayed to 0 seconds to show the direct sound from our sound source. And because we’re in a non anechoic environment, just a normal room, you can see reflections from the walls, floor, ceiling, table etcetera. in the impulse response. We can adjust the window to remove them, and you can see the frequency response updates.
This technique is very powerful, but like all techniques there are tradeoffs. So Log TSR analysis might not be the best option for all applications. The measurement resolution is affected by the window size – as the window size narrows, the frequency resolution reduces, and you can see the effects on the frequency response. This is particularly noticeable at the lower frequencies where the lack of resolution can make the data inaccurate if the window is too small. We need to be careful to configure the window size to capture the direct sound but be wide enough to get the greatest frequency resolution, without any reflections due to the test environment.
Time Selective Response Analysis offers significant benefits for several applications. We use it for the high frequency measurements in a loudspeaker simulated free field measurement, which we can then splice together with the low frequency Stepped Sine Sweep stimulus measurement. It’s also valuable for room acoustics, for example, for calculating RT60 and clarity measurements. And if you’re running open loop tests, our cross-correlation smart trigger uses a continuous log sweep to provide a way of triggering an open loop measurement that is extremely robust and far less susceptible to false triggers than other methods.
To learn more about the applications of a continuous log sweep stimulus, check out the technical papers and demo videos on our website.
https://www.listeninc.com/wp/media/2023/11/100-things-thumbnail-92.png10801920Devin Vaillancourthttps://www.listeninc.com/wp/media/logo.pngDevin Vaillancourt2023-11-16 11:42:092026-08-21 13:08:16Time Selective Response Analysis using a Continuous Log Sweep (100 Things #92)