Polar Plot (Linear X Turntable) Loudspeaker Sequence
This sequence measures the polar response of a loudspeaker in both the vertical and horizontal dimensions. It is designed to work with the Linear X turntable, and has all the necessary commands to automatically rotate it via RS-232. The sequence uses a log sweep stimulus with the Time Selective Response algorithm so that the measurements can be run in a non-anechoic environment. Note that the time window needs to be adapted to the user’s measurement space. The sequence plays the stimulus and measures at 10 degree increments from 0 to 180 degrees. This process is repeated with the speaker positioned horizontally. The two results are mirrored to display full 360 degree polar plots for each axis. A directivity index curve is also calculated for each axis and is displayed at the end of the test.




This sequence demonstrates how SC20’s new enhanced Perceptual Rub & Buzz algorithm compares to normalized Rub & Buzz and subjective listening. Running this sequence on a batch of good and bad buzzing loudspeakers should help identify by measurement, audibly defective units and where to set production limits. Starting the sequence, the user is asked at what test level to play a stepped sine sweep (Stweep™) in 1/12th octaves, from 20 kHz to 50 Hz. The user is encouraged to try different test levels and change sweep parameters to find the optimum settings to catch buzzing loudspeakers. The loudspeaker is measured via two channels of the audio interface. A calibrated reference microphone is connected to one of the channels and an impedance reference built into the SC Amp or AmpConnect is connected to the other. A HarmonicTrak™ Analysis step analyzes the recorded waveform from the reference microphone, and displays both the enhanced Perceptual Rub & Buzz and normalized Rub & Buzz graphs.


This sequence measures the anechoic response of a loudspeaker in an ordinary room using both a near field and time-windowed far field measurement “spliced” together to cover the full bandwidth of the loudspeaker’s response from 20 Hz to 40 kHz. First, the microphone is placed very close to the low frequency driver (less than an inch from the woofer), and the near field frequency response measured using a 1/12th octave stepped sine). Next, the microphone is placed in the far field and the frequency response is measured using a continuous log sweep with the Time Selective Response analysis algorithm. An option is available for measuring a ported loudspeaker. The sequence displays both measurements on a graph, showing the overlap range where the measurements are equal. From this, the user selects the precise frequency at which to splice the two halves of the measurements together to obtain the full range free field response of the loudspeaker.