Registration required

The content you have requested is available only to registered visitors. Please complete the short form below (all fields are required).

  • 简体中文 简体中文 Chinese (Simplified) zh-hans
  • English English English en
Listen, Inc.
  • Products
    • AUDIO MEASUREMENT
    • System Overview
      • What Soundcheck Measures
      • SoundCheck for R&D
      • SoundCheck for Production
      • Innovation
    • SoundCheck Software
      • Making Measurements
      • Algorithm Highlights
      • Integration
      • What’s New?
      • Packages, Modules & Pricing
      • Support Contracts
    • Audio Measurement Interfaces
      • AudioConnect 2 (2 channel))
      • AmpConnect 621 (6/2 channels)
      • AudioConnect 8×8 (8 channel)
      • AudioConnect 6×2 (6/2 channel)
      • AmpConnect ISC (2 channel)
      • 3rd Party Audio Interfaces
    • Audio Testing Hardware
      • Microphones & Amplifiers
        • Measurement Microphones
        • Microphone Power
        • Audio Test Amplifier
      • Specialist Test Interfaces
        • Bluetooth Audio Measurement Interfaces
        • MEMS microphone Interfaces
        • DC Connect
      • Audio Test Accessories
        • Turntables
        • Halo Automotive 6-Mic Array
        • Automotive Audio Test Kit
        • The SCC-1 Ear Coupler
        • Other Measurement Transducers
        • Impedance Box
        • Calibrators
    • NOISE & VIBRATION MEASUREMENT
    • System Overview
    • NoiseCheck Software
    • Noise & Vibration Interfaces
    • Noise and Vibration Testing Hardware
  • Applications
    • Headphones & Headsets
    • Loudspeakers & Microspeakers
    • Microphones
    • Automotive
    • Communications
    • Smart Devices
    • Hearing Aids
    • Audio Electronics
  • Support
    • Get Support
    • User Documentation
    • Knowledgebase
    • Training
    • Sequences & Resources
    • Drivers
    • Register Product
    • Report a Bug / Request a Feature
  • Resources
    • ‘Sound Matters’ Blog: Audio Measurement Expertise
    • Test Sequences
    • Article Reprints
    • Published Papers
    • Technical Notes
    • Measurement Services
    • Useful References
  • News & Events
    • News
    • Events
  • About Listen
    • Listen, Inc.
    • Contact
    • Distributors & Reps
    • Careers
    • Privacy Policy
  • Menu Menu

Save Test Time by Automating With Sequence Looping (100 Things #49)

January 19, 2023/in 100 Things Videos, Blog, Measurement Techniques Videos, SoundCheck Functionality Videos/by Zarina

Save both sequence development and test time by using sequence looping to run repetitive test elements in a sequence. This is valuable for any kind of test where you need to repeatedly change a test parameter, for example, increase stimulus level by 5dB and re-test, make measurements at multiple fixed frequencies or frequency sweeps, or even move a turntable and re-measure a device to create polar plots.

Automating SoundCheck Tests with Sequence Looping

Learn More About Implementing Sequence Looping

Check out our easy-to-follow tutorials on sequence looping.

More information is also available in the SoundCheck Manual.

 

Video Script: Save Test Time by Automating With Sequence Looping

Sequence looping is a useful technique that saves both sequence writing time and test time by running repetitive test elements in a loop within a sequence. This is valuable for any kind of test where you need to repeatedly change a test parameter, for example, increase stimulus level by 5dB and re-test, make measurements at multiple fixed frequencies or frequency sweeps, or even move a turntable and re-measure a device to create polar plots.

Using sequence loops instead of hard-coding each sequence step offers many advantages. It keeps your sequence shorter and easier to read, and the sequence logic is clearer. It’s much faster to program and easier to update, because if  test parameters change, they only need updating in one place. In many cases it removes the need for manual user-input while the sequence is running, making your test much faster. There are many other benefits too. Data in the memory list can be automatically named using the loop index, for example, by appending data such as stimulus of frequency level to the curve name, and you can even use loops to prompt an operator to change device settings between measurements.

Here’s a simple example where we use a basic loop to increment the stimulus level by 10dB each time and plot all the measurements on the same graph. You can see it looping through the sequence, automatically naming the curves and adding to the memory list, and plotting them on a graph.

Where it gets really useful is when you start to apply sequence logic. Using commands such as “jump on pass” and “jump on fail” you can determine the next steps in the sequence based on the results of the measurement. For example, if the device passes the test you can increment the level and re-measure, and if it fails you could decrease the level and repeat the test, or end the test and produce a report. You can also nest loops for more complex test procedures. You can see this being put to good use in our AES-75 test sequence. This determines the maximum SPL of a loudspeaker using multiple loops and logic to repeat a measurement at different levels, and compares the results to a baseline measurement to determine the next sequence step.

SoundCheck’s looping capability even extends to working with previously saved data, where it can iterate through a set of files in a folder, applying post-processing calculations, statistical analyses and more, and displaying the results in a user-defined way. This is a standard feature in SoundCheck, and its been available in all versions for over 20 years!. Check out SoundCheck tutorial #7 on our Youtube channel if you want to learn more about how to use this useful feature!

 

https://www.listeninc.com/wp/media/2023/11/100_things_49_thumbnail.png 1080 1920 Zarina https://www.listeninc.com/wp/media/logo.png Zarina2023-01-19 11:42:062025-01-21 16:54:07Save Test Time by Automating With Sequence Looping (100 Things #49)

Using Equalization Curves For Calibrated Measurements (100 Things #44)

December 1, 2022/in 100 Things Videos, Blog, Measurement Techniques Videos, SoundCheck Functionality Videos/by Zarina

Equalization curves are essential for creating flat frequency responses from speakers, allowing for them to be used as reliable references for testing devices like microphones. SoundCheck has functionality integrated directly into the calibration editor. From a single window, SoundCheck can measure and apply an equalization curve to your device, for use in any testing application.

Using Equalization Curves For Calibrated Measurements

Learn More About Equalizing Curves in SoundCheck

View more detailed tutorials on how to use this functionality. (In the Calibration section)

Read our knowledgebase article on how to apply equalization to an artificial mouth for a flat response.

 

Video Script: Using Equalization Curves For Calibrated Measurements

Did you know you can easily create an equalization curve for a speaker in SoundCheck? This works with loudspeakers, speakers in smart devices, headphones, telecommunication devices, and anything else you might want to equalize .

An equalization curve is used to modify the stimulus waveform before it is played out of a source speaker or mouth simulator. By compensating for a speaker’s non-linear magnitude and phase response on a per-frequency basis, a near flat frequency response from the speaker can be achieved. This allows the speaker to be used as a reliable reference across a specified frequency range in a test sequence most often used in the testing of microphones. In SoundCheck, this adjustment is made to the stimulus waveform before it is played during the acquisition step.

Creating an equalization curve for your device is simple with SoundCheck. In the output tab of the calibration editor, there is a set of sequences available. The Speaker Equalization sequence will provide a simple step by step process to create an EQ curve in seconds. Select the signal path you will be using in your test, then your Output Calibrated Device to have the EQ curve linked with. Once this sequence is complete, the EQ curve is stored in the selected Output Calibrated Device file.

Alternatively, if you already have an EQ curve, you can import and use this curve through the memory list. In the output tab of the calibration editor, select the option Copy From Memory List. The Import Calibration Data dialog box will allow you pick the source curve, the desired Output Calibrated Device, and will give the option to invert the curve if needed, right in the editor.

How do you use an EQ curve in SoundCheck? Simply put, anywhere you need! The stimulus editor features an EQ checkbox, which when enabled, will apply the equalization curve before the signal is output from the speaker during the Acquisition step. Since the EQ curve is tied to the Output Calibrated Device selected with the Signal Path, SoundCheck will automatically use the correct curve. Alternatively the EQ curve can be applied in the Signal Generator to equalize all of the available signal types, even when using a signal generator in a virtual instrument acquisition step.

SoundCheck is focused on giving audio test engineers every tool they may need, so no matter what device you are working with, we provide the right tools for the job.

 

 

https://www.listeninc.com/wp/media/2023/11/100_things_44_thumbnail.png 1080 1920 Zarina https://www.listeninc.com/wp/media/logo.png Zarina2022-12-01 14:50:382026-08-21 15:07:09Using Equalization Curves For Calibrated Measurements (100 Things #44)

Digital Measurements – USB Headphones & Microphones (100 Things #38)

October 13, 2022/in 100 Things Videos, Blog, Headphone & Headset Videos, Measurement Techniques Videos, Microphone Videos/by Zarina

SoundCheck’s testing capabilities go beyond the analog domain. It has always been able to measure digital devices and make both analog and digital domain audio measurements simultaneously on different channels. The digital inputs and outputs inside SoundCheck are easily configured to measure USB Headsets, MEMS microphones and so on. Watch this short video to learn more.

Measuring Digital Devices with SoundCheck

Learn More About SoundCheck’s Signal Generator and other Virtual Instruments

Check out our pre-written test sequence on measuring digital MEMS microphones

 

Video Script: Measuring Digital Devices such as USB Headphones & Microphones in SoundCheck

When we talk about measuring traditional transducers such as microphones and loudspeakers, we are measuring analog devices that respond to voltage and pressure. Nowadays, most microphones and loudspeakers have become quasi analog/digital devices because their analog signals are immediately transformed into the digital domain built into the design and transducer package.  With digital devices dominating the consumer electronics market today, have you wondered if you can set up digital inputs and outputs inside SoundCheck to measure USB Headsets, MEMS microphones and so on? The answer is yes.

SoundCheck supports both analog and digital inputs and outputs for measurement. Setting up digital inputs and outputs is very straightforward. All you need to do is create a new digital channel on your Hardware editor, set it to  input or output and select the appropriate digital calibration reference e.g. AES-17 when configuring the signal path inside the calibration editor. It is as simple as that and you should be ready to use your connected digital device to make audio measurements.

The digital interface can be as simple as a USB headset plugged in directly to your computer or a device plugged into a supported audio interface, or as complex as a bunch of MEMS microphones going through a digital circuit board before interfacing with the test system. You can also use a USB headphone as an input monitor if your audio interface doesn’t have one, and analog and digital inputs and outputs can be used simultaneously.

SoundCheck offers great flexibility for testing both analog and digital devices. If you’d like to take a closer look at how this works, please contact your sales engineer for a demo.

 

 

https://www.listeninc.com/wp/media/2023/11/100_things_38_thumbnail.png 1080 1920 Zarina https://www.listeninc.com/wp/media/logo.png Zarina2022-10-13 15:04:172026-08-21 15:17:24Digital Measurements – USB Headphones & Microphones (100 Things #38)

Comparing Measured Data to a Target Curve (100 Things #33)

September 8, 2022/in 100 Things Videos, Blog, Headphone & Headset Videos, Measurement Techniques Videos, SoundCheck Functionality Videos/by Zarina

You can import any target curve into SoundCheck. This enables quick and easy comparison of your measured data to any reference data.

Comparing Measured Data to Target Curves in SoundCheck

More Target Curve Resources

To see an example of using Target Curves in SoundCheck, take a look at the work we’ve done with the Harman Target Curve. This page also links to the sequence that you can download to use with SoundCheck.

 

Video Script: Comparing Measured Data to Target Curves

Did you know that you can import any target curve in SoundCheck? This lets you compare your measured data to any reference data, fast and easy.

This functionality is simple to use – simply import the curve into the memory list and from there, use it in a sequence or drag and drop it onto any graph.

One of the simplest examples of this capability is to compare measured results to a golden unit.  All you have to do is  import the data from the golden unit into the memory list, then plot it on the same graph as the measured unit. You can use mathematical functions to statistically compare the curves, or you can use the curve offset by a fixed dB level, and use it as a limit.

Another example is live tuning. Matching a frequency response and sound pressure level is a common audio test, from measuring loudspeakers in a shop environment to tuning an automotive infotainment system. In these tests, you can compare RTA generated live curves to the imported target curve, and adjust the microphone location or manipulate the sound source in real time to match the target curve.

We also offer a more advanced application of target curves in a free test sequence that calculates a listener preference rating for headphones based on the Harman Target curve, developed by Sean Olive. This sequence measures the frequency response of your headphones and calculates an error curve, which is derived from subtracting the Harman Target Curve from an average of the headphone left/right response. The standard deviation, slope and average of the Error curve are used to calculate the predicted preference score.

So whether you are performing real-time measurements with live curves, setting limits based on golden units, or predicting listener preference of headphones, SoundCheck’s curve-importing capability makes your audio testing easier.

 

 

 

 

 

https://www.listeninc.com/wp/media/2023/11/100_things_33_thumbnail.png 1080 1920 Zarina https://www.listeninc.com/wp/media/logo.png Zarina2022-09-08 17:01:452026-08-21 14:44:34Comparing Measured Data to a Target Curve (100 Things #33)

100 Things #20: Send A Message to Any External Device

June 9, 2022/in 100 Things Videos, Blog, Measurement Techniques Videos, SoundCheck Functionality Videos/by Devin Vaillancourt

Using SoundCheck to communicate with outside hardware and software opens up a world of testing possibilities. The System custom steps allows for SoundCheck sequences to integrate command line actions, communication with devices like smartphones and smart speakers, and configure network connections. Smart device testing can be fully automated using SoundCheck custom steps, eliminating the need for user interaction during testing and avoiding errors in test configuration.

Send A Message to Any External Device

Learn about SoundCheck custom steps and more

Communicating with external devices is just one example of SoundCheck’s power and flexibility. Learn more about all of SoundCheck’s features and functionality here.

Video Script:

SoundCheck’s ‘System’ custom step enables you to interact with external hardware and software applications from within a sequence. This makes it easy to communicate with devices under test, facilitates device actions, and changes audio processing and test parameters using a simple, integrated, cross platform command-line utility. 

Using the ‘System’ custom step, you can launch external applications and pass commands the same way as you would using the Command prompt in Windows or Terminal on your macOS. You can even save a set of command line instructions as a batch script and run this from within SoundCheck, to save time and prevent coding errors. You can also use this step to trigger audio files to play through smart speakers, enable microphones in an array, and trigger additional audio processing outside SoundCheck using utilities such as SoX.

Let’s look at an example. Let’s say I need to measure how linearly the sound level of the speaker changes when I press the volume Up and Down buttons on this Android phone. I don’t want to physically press these buttons in the test chamber as it could introduce errors by changing the orientation of the speaker between each test run. Instead, I can operate these buttons remotely from within my SoundCheck sequence. I just need to configure the custom’ System’ step to call the Android Debug Bridge – command line utility provided in Google’s Android SDK that allows control of the device via USB. These levels can then be adjusted automatically without me needing to touch the phone.

SoundCheck’s System custom step is not just powerful enough to be used in a complex automated test sequence, but also versatile enough to handle routine tasks such as opening sequence notes, configuring network connections or simply opening a calculator.

https://www.listeninc.com/wp/media/2023/10/100-things-20-thumbnail.png 720 1280 Devin Vaillancourt https://www.listeninc.com/wp/media/logo.png Devin Vaillancourt2022-06-09 08:30:552026-08-24 16:33:33100 Things #20: Send A Message to Any External Device

100 Things #19: Maximize Dynamic Range with Autoranging

June 2, 2022/in 100 Things Videos, Blog, Measurement Techniques Videos, SoundCheck Functionality Videos/by Zarina

It is important to maximize dynamic range to ensure a good signal-to-noise ratio when making measurements. SoundCheck’s autoranging feature monitors the available headroom on the input signal path and automatically adjusts the gain of the supported interface for best performance.

Maximize Dynamic Range with Autoranging

Learn More About Maximizing Dynamic Range in SoundCheck

More information is also available in the  SoundCheck Manual.

 

Video Script: Maximize Dynamic Range with Autoranging

A good signal-to-noise ratio is important for sound measurements, particularly for critical distortion measurements like THD and Rub and Buzz.  Insufficient signal-to-noise allows the harmonic content of the response to fall into the noise floor resulting in imprecise analyses.

There are several ways to improve the signal-to-noise ratio of your acquisitions. You can measure in an anechoic chamber or test box to isolate out background or factory noise. You can also measure in the near field by placing the measurement mic closer to your device under test. If your hardware supports input gain, you can manually adjust this on your interface to optimize signal-to-noise.

Listen’s audio interfaces including AudioConnect, AmpConnect ISC and AmpConnect 621, as well as the SoundConnect 2 microphone power supply,  all support input gain. But we have taken it one step further! The auto-ranging capability in the SoundCheck software allows gain to be  automatically applied to optimize the signal-to-noise ratio.

Here’s how it works: when auto-ranging in SoundCheck is enabled, SoundCheck monitors the available headroom on the input signal path. It reports this as MaxFSD in SoundCheck’s memory list. If gain can be applied without reaching digital saturation, SoundCheck automatically adjusts the gain of the supported interface, and takes another acquisition.

Auto-ranging assures that you automatically have an optimal acquisition without manually adjusting gain, giving you confidence in your measurements and results and accelerating test development.

 

 

https://www.listeninc.com/wp/media/2023/11/100_things_19_thumbnail.png.png 720 1280 Zarina https://www.listeninc.com/wp/media/logo.png Zarina2022-06-02 15:36:072026-08-26 15:39:32100 Things #19: Maximize Dynamic Range with Autoranging

100 Things #17: Simulated Free Field Measurements Without an Anechoic Chamber

May 19, 2022/in 100 Things Videos, Blog, Loudspeaker Videos, Measurement Techniques Videos/by Devin Vaillancourt

With SoundCheck you can make simulated free field measurements in an ordinary room without an anechoic chamber – in a typical lab, office, or even your home. By performing near field and far field measurements, we are able to utilize the measurement strengths of each technique; near field measurements for low frequencies and room reflection immunity, and time-windowed far field measurements for high frequencies. Splice these measurements together, and the result is the free field response of the loudspeaker. All without an anechoic chamber, and all within a single SoundCheck sequence.

Simulated Free Field Measurements Without an Anechoic Chamber

Learn more about free field measurements with SoundCheck

In this online seminar, Steve Temme explains how to use simulated free field measurements to provide accurate free-field measurements across the entire audible frequency range without an anechoic chamber. This seminar talks about setup and equipment considerations, testing in different environments, and analysis of results.

Try simulated free field measurements for yourself with our Splice sequence, available in our sequence library.

Video Script:

Free field loudspeaker measurements are often included in loudspeaker specifications. These measurements are usually made in an anechoic chamber. However, anechoic chambers are not cheap, particularly those large enough to give accurate measurements at low frequencies. This means that many engineers don’t have easy access to a suitable chamber, even more so if they are working from home.

With SoundCheck you can make free field measurements in an ordinary room without an anechoic chamber – in a typical lab, office, or even your home. Here’s how it’s done.

First, measure the near field response of the loudspeaker using a stepped sine sweep or Stweep, and placing the microphone very close to the low frequency driver. If the loudspeaker is ported, you also need to make a measurement at the port or ports. This near field measurement is accurate at low frequencies as it’s unaffected by room reflections, but it does not accurately represent the free field response at high frequencies. 

Next, place the microphone in the far field and measure the time-windowed frequency response using a continuous log sweep with the Time Selective analysis algorithm. The far field, time-windowed measurement is unaffected by room reflections, but it is not accurate at low frequencies as the room size limits the width of the time window and therefore the frequency resolution.

Now, if you examine the two responses you can see an overlap range in the middle where the shapes of the curves align. Using this, you can select a precise frequency to splice the two halves of the measurement together and display a response over the entire frequency range. This is implemented in several post-processing steps which include calculating the impulse response, and automatically correcting for differences in amplitude and phase.

Here you can see the simulated free-field response measured using this method compared to the same speaker measured in an anechoic chamber. In fact, the simulated free field response is actually more accurate than the anechoic chamber measurements because of its small size and 120Hz cut-off frequency

We can also compare our measurements to the manufacturer’s published data. Here we see a tight correlation across the whole frequency range, even at low frequencies – likely because a much larger chamber was used.

If you want to know more, there’s a detailed seminar covering both the theory and practical aspects on our YouTube channel, and a pre-written test sequence for use with SoundCheck can be downloaded from our website for free!

https://www.listeninc.com/wp/media/2023/10/100-things-17-thumbnail.png 720 1280 Devin Vaillancourt https://www.listeninc.com/wp/media/logo.png Devin Vaillancourt2022-05-19 08:30:042026-08-21 13:56:43100 Things #17: Simulated Free Field Measurements Without an Anechoic Chamber

100 Things #6: Open Loop Testing of Smart Devices Using Triggered Record

March 3, 2022/in 100 Things Videos, Blog, Measurement Techniques Videos, Smart Device Videos/by Devin Vaillancourt

Triggered record is an essential feature for open loop audio tests – any test where the stimulus and response are asynchronous. This includes, for example measuring smart devices, automotive systems, or anywhere that signals travel wirelessly via Bluetooth or the cloud. In this short video, we review the three different triggered record options in SoundCheck.

Open Loop Testing of Smart Devices Using Triggered Record

Learn more about testing smart devices

Our full Smart Device Testing seminar features test demonstrations of smart homes, Bluetooth headphones, and active noise cancellation. Device design considerations and individual component tests are shown, and how SoundCheck can measure audio quality from R&D to production.

Video Script:

Triggered recording is an essential feature for open loop audio tests – any test where the stimulus and response are asynchronous. This includes, for example measuring smart devices, automotive systems, or anywhere that signals travel wirelessly via Bluetooth or the cloud.

Triggered record was first introduced into SoundCheck in 2007 but did you know that there are now three triggered record options available in SoundCheck? 

Lets take a quick look…

The level trigger is the simplest implementation of this feature.  The user selects the signal path, trigger level and record duration and once the level is exceeded, the step will record for the prescribed duration.

Level triggers can be error prone and for this reason the level and frequency trigger was developed and introduced in 2017.  In order to begin recording, not only does the level need to be exceeded but a sinewave must also be detected. In this case, the stimulus should be prepended with a pilot tone.

The third option, a level and cross-correlation trigger is the most accurate.  This method uses  a chirp-based conditioning tone and searches for the exact sweep range, making it more robust and less susceptible to false triggers than the simpler level and frequency options.

https://www.listeninc.com/wp/media/2023/10/100T_6_Open_Loop_Thumbnail.png 1080 1920 Devin Vaillancourt https://www.listeninc.com/wp/media/logo.png Devin Vaillancourt2022-03-03 08:30:152026-08-24 16:31:23100 Things #6: Open Loop Testing of Smart Devices Using Triggered Record

100 Things #5: Test Devices Using Speech or Music

February 24, 2022/in 100 Things Videos, Blog, Measurement Techniques Videos, SoundCheck Functionality Videos/by Devin Vaillancourt

SoundCheck can test devices using any .wav file as a stimulus. This enables real signals such as speech or music to be used in any audio test. Speech signals are used for telephony and voice activation and in testing to IEEE and ITU standards that use P50 speech and ITU Real speech recordings. These ‘real world’ test signals are also valuable for measuring devices that include nonlinear signal processing such as cell phones and hearing aids, as these often do not test accurately with sine waves.

Test Devices Using Speech or Music

Learn more

Read on about all of SoundCheck‘s stimulus options and more, with features perfect for R&D and Production.

Video Script:

SoundCheck can test devices using any .wav file as a stimulus. This functionality, available since 2004, enables real signals such as speech or music to be used in any audio test. Speech signals are used for telephony and voice activation and in testing to IEEE and ITU standards that use P50 speech and ITU Real speech recordings. These ‘real world’ test signals are also valuable for measuring devices that include nonlinear signal processing such as cell phones and hearing aids, as these often do not test accurately with sine waves.

Testing devices using music as a stimulus enables measurements, such as non-coherent distortion, to be made with test signals that simulate the product-use, returning results that correlate well to listener experience.

The use of wav files also means that in the rare case you want to use a custom signal that cannot be created using SoundCheck’s stimulus editor, it can be made in another program and imported as a WAV file for use in SoundCheck.

All Wav files can, of course, be calibrated and equalized in SoundCheck, ensuring reproducibility and compliance to standards.

More recently, in 2019, we added the capability for SoundCheck to open multichannel WAV files into the memory list, signal generator and stimulus steps. This enhances the testing of smart devices and microphone arrays, conveniently auto-naming and grouping the channels together.

So there you have it, wav files introduce the ultimate in flexibility to your test stimuli.

https://www.listeninc.com/wp/media/2023/10/100T_5_Speech_Music_Thumbnail.png 1080 1920 Devin Vaillancourt https://www.listeninc.com/wp/media/logo.png Devin Vaillancourt2022-02-24 08:30:292026-08-24 16:39:11100 Things #5: Test Devices Using Speech or Music

100 Things #1: The ‘Stweep’ – SoundCheck’s Optimized Stepped Sine Sweep Stimulus

January 28, 2022/in 100 Things Videos, Blog, Measurement Techniques Videos, SoundCheck Functionality Videos/by Devin Vaillancourt

The Stweep test signal, one of the most efficient, accurate, noise-immune and flexible audio test signals in use today, was engineered by Steve Temme, Listen’s founder. It has been included in SoundCheck since the first version was released back in 1995. In this short video, we explain how it is different from the conventional stepped sine sweep used in most test systems and how its unique features enable shorter test times and excellent noise immunity for production environments.

The ‘Stweep’ – SoundCheck’s Optimized Stepped Sine Sweep Stimulus

Learn more

Read on about all of SoundCheck‘s stimulus options and more, with features perfect for R&D and Production.

Video Script:

The Stweep test signal, one of the most efficient, accurate, noise-immune and flexible audio test signals in use today, was engineered by Steve Temme, Listen’s founder. It has been included in SoundCheck since the first version was released back in 1995. 

So how is this different from the conventional stepped sine sweep used in most test systems?

A regular stepped sine sweep is not a continuous sweep – rather it plays a sine wave at discrete frequencies, step by step, within a user defined frequency range, and the user sets a resolution value to determine how many steps there will be.

SoundCheck’s ‘Stweep’ is an optimized stepped sine sweep that generates an integer number of cycles at each frequency step, ensuring a smooth “zero crossing” transition from step to step. This reduces transducer ringing and decreases settling time which yields faster and more accurate measurements. 

What makes it unique is that it is phase-continuous from frequency step to frequency step, in fact because of this, it sounds more like a sine chirp than a stepped sine. The Stweep can be user-configured with different resolutions to optimize the trade-off between stimulus duration and resolution.

Although the Stweep has been included in SoundCheck since 1995, it has more recently been refined to include a fast continuous sweep from one frequency to the next to further smooth the transitions, especially when the steps are large or when equalization is required.

It is innovations such as this that maintain the value of stepped sine signals as one of the most fundamental and powerful test stimuli in the audio analysis toolkit – the Stweep’s high speed and noise immunity make it an excellent choice for extremely fast production line measurements of parameters such as frequency response, phase, harmonics, and distortion measurements such as THD, Rub & Buzz and Perceptual Rub and Buzz. We’re just surprised that it’s only in the past year or so that other test system manufacturers have started to pay attention to this versatile stimulus.

https://www.listeninc.com/wp/media/2023/10/100-things-1-thumbnail.jpg 720 1280 Devin Vaillancourt https://www.listeninc.com/wp/media/logo.png Devin Vaillancourt2022-01-28 08:30:092026-08-24 16:40:16100 Things #1: The ‘Stweep’ – SoundCheck’s Optimized Stepped Sine Sweep Stimulus
Page 2 of 3123

Audio Measurement Expertise


How Changing Industry Needs are Shaping Audio Test and Measurement

Smarter SoundCheck Sequences with Loops and Logic

Audio Basics: Polarity

How to Measure: Haptics

The Value of Big Data

Audio Basics: Phase Response

view all

Latest News


2026 End Of Year Promotions

Celebrating 30 years: Listening – The Secret Of Our Success

Automotive Test Sequence Including BSR, Max SPL and Frequency Response

Listen Introduces AudioConnect 2, a New Portable Dual-Channel Audio Interface

SoundCheck 21 Brings Enhanced Loose Particle Detection, Multichannel FFT, Metadata, Sequence Protection and more


Audio Measurement Expertise – Delivered Monthly

 

ABOUT LISTEN INC

Listen is a global leader in audio measurement and analysis, with over 30 years’ experience developing innovative test methods and algorithms. SoundCheck, our powerful software-based audio analyzer, pairs with our test interfaces, precision microphones, and accessories to offer a complete solution for testing loudspeakers, headphones, microphones, smart devices, communication systems, hearing aids, automotive audio, and more. Trusted by engineers worldwide, Listen delivers the accuracy and flexibility essential for modern audio testing, from the R&D lab to the production line.

PRODUCTS
APPLICATIONS
SUPPORT
RESOURCES
NEWS & EVENTS
ABOUT

CONNECT

YouTube
LinkedIn
LinkedIn
Share
Instagram

Copyright © Listen, Inc.   |   Privacy Policy   |   AI Disclosure
  • Instagram
  • LinkedIn
  • Youtube
  • Mail
Scroll to top