Registration required

The content you have requested is available only to registered visitors. Please complete the short form below (all fields are required).

  • 简体中文 简体中文 Chinese (Simplified) zh-hans
  • English English English en
Listen, Inc.
  • Products
    • AUDIO MEASUREMENT
    • System Overview
      • What Soundcheck Measures
      • SoundCheck for R&D
      • SoundCheck for Production
      • Innovation
    • SoundCheck Software
      • Making Measurements
      • Algorithm Highlights
      • Integration
      • What’s New?
      • Packages, Modules & Pricing
      • Support Contracts
    • Audio Measurement Interfaces
      • AudioConnect 2 (2 channel))
      • AmpConnect 621 (6/2 channels)
      • AudioConnect 8×8 (8 channel)
      • AudioConnect 6×2 (6/2 channel)
      • AmpConnect ISC (2 channel)
      • 3rd Party Audio Interfaces
    • Audio Testing Hardware
      • Microphones & Amplifiers
        • Measurement Microphones
        • Microphone Power
        • Audio Test Amplifier
      • Specialist Test Interfaces
        • Bluetooth Audio Measurement Interfaces
        • MEMS microphone Interfaces
        • DC Connect
      • Audio Test Accessories
        • Turntables
        • Halo Automotive 6-Mic Array
        • Automotive Audio Test Kit
        • The SCC-1 Ear Coupler
        • Other Measurement Transducers
        • Impedance Box
        • Calibrators
    • NOISE & VIBRATION MEASUREMENT
    • System Overview
    • NoiseCheck Software
    • Noise & Vibration Interfaces
    • Noise and Vibration Testing Hardware
  • Applications
    • Headphones & Headsets
    • Loudspeakers & Microspeakers
    • Microphones
    • Automotive
    • Communications
    • Smart Devices
    • Hearing Aids
    • Audio Electronics
  • Support
    • Get Support
    • User Documentation
    • Knowledgebase
    • Training
    • Sequences & Resources
    • Drivers
    • Register Product
    • Report a Bug / Request a Feature
  • Resources
    • ‘Sound Matters’ Blog: Audio Measurement Expertise
    • Test Sequences
    • Article Reprints
    • Published Papers
    • Technical Notes
    • Measurement Services
    • Useful References
  • News & Events
    • News
    • Events
  • About Listen
    • Listen, Inc.
    • Contact
    • Distributors & Reps
    • Careers
    • Privacy Policy
  • Menu Menu

all videos

Frequency Normalized Distortion Seminar

February 10, 2026/in Blog, Seminar Recordings/by Julius Wijono

Recent transducer development, particularly piezo-MEMS loudspeakers, have brought renewed attention to Normalized Distortion (also known as Frequency Normalized Distortion), because it is essential to accurately characterize their behavior.

Normalized Distortion is a measurement algorithm first proposed in a 1993 AES paper by Listen president Steve Temme during his time at Brüel & Kjær. Although it has been available in SoundCheck since 1996 and used by some engineers for nearly 30 years, interest in the technique has surged recently. This renewed focus is driven both by the industry’s increasing emphasis on correlating measurements with audibility – an area Listen has long prioritized – and by the emergence of new microspeaker technologies that cannot be fully evaluated using conventional distortion measurements.

In this seminar, we’ll first explain distortion mechanisms and talk about correlating measured results to what we hear using masking curves. We’ll then examine how normalized distortion differs from the conventional approach and show why it’s essential for characterizing modern piezo-MEMS loudspeakers.

This seminar presentation includes:

  • Psychoacoustics
  • Even Order Distortion
  • Odd Order Distortion
  • Threshold of Hearing
  • Auditory Tonal Masking
  • Masking vs. Level
  • Masking vs. Frequency
  • Masking of High Order Harmonics
  • Real-Time Masking Curves
  • Linear vs Nonlinear Effects
  • Plotting Harmonic Curves
  • Dynamic Speaker Normalized THD Measurements
  • Conventional Dynamic vs. MEMS Speaker
  • MEMS Speaker Measurement Test Configuration
  • Piezo-MEMS Speaker Conventional THD Measurements
  • Piezo-MEMS Speaker Normalized THD Measurements

Presenter: Steve Temme
Duration: 30 Mins

Frequency Normalized Distortion Resources

How to Graph Distortion Measurements: Original 1993 paper where normalized THD was introduced.

The Value of Normalized Distortion: Blog post on the value of normalized distortion.

MEMS Speaker Measurements: 100 Things video on MEMS speaker measurements.

Smart Glasses Audio Measurement: A video demo on how to measure smart glasses audio.

https://www.listeninc.com/wp/media/2026/02/Measuring-Distortion-Intro.png 1080 1920 Julius Wijono https://www.listeninc.com/wp/media/logo.png Julius Wijono2026-02-10 17:39:552026-08-21 12:41:59Frequency Normalized Distortion Seminar

How to Average Data in SoundCheck

January 6, 2026/in Blog, SoundCheck Tips Videos/by Julius Wijono

Learn how to average measurement data the right way in SoundCheck. In this video, we’ll walk through curve averaging, averaging multiple curves, and waveform RMS calculations to get meaningful results from your data.

Additional Resources for SoundCheck

Detailed explanations of how to use SoundCheck can be found in the SoundCheck manual.

Video Transcript: How to Average Data in SoundCheck

There are several ways we can average data in SoundCheck. The sequence step that you use depends on your input data and what you’re actually trying to get out of it. Let’s look at some examples.

First, let’s find the average of a single curve. We can do this using a post-processing curve average step. Here, my input is curve one. My operation is average. And when I output this value, it’ll give me the average value of all of the magnitude values from my curve as the Y axis, and also the average phase data as the Z axis on the value.

Now let’s find the average of a number of curves. We use this all the time, for example finding the power average of multiple microphones in an array. Here I have eight different curves and I want to find the average not of one but of all eight. Instead of a curve average step here, I’ll use an average curve step. First, I need to put all these curves into a group. I’ll just call it curves. And then in this post-processing step, I’ll choose the group that I’m interested in, which could be either curves or waveforms, and the averaging type. I have the option of complex, which will include phase data, or power, which won’t. I’ll use power for now. Rather than outputting a single value like we had before, this generates a curve that’s the average of all of my curves. And I can even put this on my display. And you’ll see that this curve here, the average curve, is now on my graph alongside the other curves.

We can also average waveform data. Here I have a one volt RMS sine tone. I might want to know what the average of this is here. If we use a curve average step, because this is a waveform and there’s positive and negative data, the average is going to be about zero, which isn’t very interesting to me. Instead, we could use the waveform RMS step. I can input my waveform. And this gives me an output of one volt RMS, which is as expected since that’s what I have set for my waveform here.

So that’s 3 easy ways we can find averages in SoundCheck. Check the manual for more details.

https://www.listeninc.com/wp/media/2026/01/Average-Data-Blog-TN.png 1080 1080 Julius Wijono https://www.listeninc.com/wp/media/logo.png Julius Wijono2026-01-06 05:00:152026-08-27 13:59:38How to Average Data in SoundCheck

SoundCheck’s FFT Analyzer and RTA: Live or in a Sequence

December 23, 2025/in Blog, SoundCheck Tips Videos/by Julius Wijono

Understand when to use SoundCheck’s FFT Analyzer and RTA live versus in a sequence. In this video, we’ll show how live multi-instrument FFT/RTA measurements are ideal for real-time adjustments and troubleshooting, while sequence-based analysis steps enable automated, repeatable measurements, averaging over time, and advanced calculations like frequency response.

Additional Resources for SoundCheck

Detailed explanations of how to use SoundCheck can be found in the SoundCheck manual.

Video Transcript: SoundCheck’s FFT Analyzer and RTA: Live or in a Sequence

In SoundCheck, you can run an FFT or an RTA either live via the multi-instrument or through the analysis step in a sequence. 

Let’s outline the differences.

Taking an FFT or an RTA via the multi-instrument is always an input-only measurement and it displays the live curves and changes over here in the graph. So, as I’m talking, you’ll see that these are displaying the current measurement on my reference microphone. This is very helpful for live adjustments – for example if I’m changing the DSP on a device and I want to see how it behaves, or checking the seal on some headphones. When you’re looking at it live, you can change settings on the fly, so using these controls I can see what happens if I switch from average to max hold, min, or change the windowing or weighting directly in the instrument. Most of this can be done in the analysis step as well, but you might have to rerun the acquisition or open an editor and click apply before you’re able to see the results, whereas here you can see the changes instantly. 

The instrument is also very helpful for troubleshooting. If something is wrong with a measurement,you can just open up an FFT or an RTA to troubleshoot what’s happening and then solve it.

If we instead look at the FFT and RTA in a sequence, I can use an acquisition step  set  to record only. I can then run that reference microphone recording through an FFT spectrum analysis step and an RTA spectrum analysis step to get the FFT and RTA spectrum response for my reference mic. Instead of seeing live changes, I can define the full time length I’m recording and then average across that full recording. This is useful if you want to test something over a set number of seconds and just see the total average there without any additional user interaction. It’s much easier to automate.

There are some calculations we can do in the live multi-instrument. For example, I can look at the power average of multiple inputs and do some basic operations like subtraction and addition. One of the options we have here that’s exclusive to the live multi-instrument is a masking curve. I can play a signal here, add a masking curve, and I can then quickly see what parts of my spectrum are being masked by a dominant tone. That’s only available in the live multi-instrument.

Virtual instruments can be added to sequences in an acquisition step. When used this way, both the instrument and analysis steps output the curves to the memory list of the sequence once the step is complete. Post processing, limits, or statistics can be used for further calculations on the measurements.

There are two common use cases where an analysis step would be required rather than using the virtual instrument: Using previously recorded waveforms and measuring a frequency response.

For example, if I have wave file recordings from a past measurement, or an open-loop test, I can recall those and add them directly into an analysis step. 

We also use an RTA analysis step to measure the frequency response of a device under test. The virtual instrument only calculates an RTA Spectrum of the input signal path, but the analysis is able to calculate spectra for both the Stimulus and Analysis waveforms. This then allows a frequency response calculation. The FFT analysis step will only measure a spectrum for the response waveform, but using the Transfer Function analysis step you can perform complex FFT on the stimulus and response waveform to output a frequency response.

https://www.listeninc.com/wp/media/2025/12/FFT-Analyzer-and-RTA-Blog-TN.png 1080 1080 Julius Wijono https://www.listeninc.com/wp/media/logo.png Julius Wijono2025-12-23 05:00:172026-08-27 13:49:53SoundCheck’s FFT Analyzer and RTA: Live or in a Sequence

Measuring Time Delay in a Mic Array

December 9, 2025/in Blog, SoundCheck Tips Videos/by Julius Wijono

Measure time delay in microphone arrays with SoundCheck! In this video, we’ll show you how to calculate both absolute and relative record delays across multiple microphones for more accurate, time-aligned measurements.

Additional Resources for SoundCheck

Detailed explanations of how to use SoundCheck can be found in the SoundCheck manual.

Video Transcript: Measuring Time Delay in a Mic Array

When we make an audio measurement, there is always a time delay between the stimulus playback and the recording. We call this “record delay”. In a mic array, each microphone has its own record delay and sometimes you need to know the absolute delay between each mic and the stimulus, or the relative delay between each mic using one of them as a reference.

Here is a simple sequence to calculate the absolute delay. 

I play a sweep through my speaker. There’s a play and record acquisition step which records simultaneously on three calibrated microphones in my array, mic one, mic two, and mic three, so I get three recorded time waveforms from this step.

Let’s run the sequence up to this break-point here…

Now you can see we have our three three recorded time waveforms in the memory list. I’ve grouped these and labelled them RTWs. 

Next we use an analysis step to calculate the delay or the record delay between these microphones. Any of these analysis algorithms can be used as they all output the delay value for the waveforms.

To find the absolute delay for these microphones, we’ll use the stimulus itself as the stimulus waveform and the group of three RTWs as the response. When I click apply, I get record delay values for the three microphones. 

Now I’ll remove this break point and run the entire sequence one more time. We hear the stimulus; it’s recorded simultaneously on the three microphones, and the display shows the fundamental response for each microphone along with the record delay values. These record delay values can be represented as time in seconds, or in inches or samples. 

Now let’s calculate relative delay. We’ll use mic 1 as the reference mic, and calculate the relative delay of mic 2 and mic 3 compared to mic 1. 

To do this, let’s use the recorded time waveform for mic 1, since it’s my reference, as the stimulus in the analysis step. And we’ll use other recorded time waveforms as the response. Let’s run the sequence. 

Now you see that I get the record delay values compared to the first mic. Mic 1 is showing a delay of zero as that’s the new reference point.  Mic two has a time delay of 90.7 microseconds, compared to mic one, and mic three has a record delay of 68 microseconds.

This concept of using a non-stimulus waveform as the reference in the analysis step is a valuable technique with many other applications in audio test, for example, dual channel impedance measurements.

https://www.listeninc.com/wp/media/2025/12/Measuring-Time-Delay-Blog-TN.png 1080 1080 Julius Wijono https://www.listeninc.com/wp/media/logo.png Julius Wijono2025-12-09 12:18:182026-08-27 13:51:15Measuring Time Delay in a Mic Array

Importing Correction Curves for Calibration

November 25, 2025/in Blog, SoundCheck Tips Videos, Uncategorized/by Julius Wijono

Easily calibrate your measurement chain by importing correction curves directly into SoundCheck. In this video, we’ll show you how to load external data, apply it to a signal path, invert response curves when needed, and ensure your corrections are properly applied during analysis for accurate test results.

Additional Resources for SoundCheck

Detailed explanations of how to use SoundCheck can be found in the SoundCheck manual.

Video Transcript: Importing Correction Curves for Calibration

It’s simple to calibrate signal paths in SoundCheck using either imported data or measurements you’ve made. This is useful, for example, if you need a frequency and phase correction curve for an input transducer, or a DRP to ERP correction.

To apply a calibration curve, the calibration data first needs to be in the memory list. If your data is in an external file, for example if you have a microphone frequency response curve from a calibration lab, you just select “open data” from the data menu of the memory list… and you can see now it shows up in the list. SoundCheck supports a wide range of formats from our own .dat format to txt and csv files.

Alternatively, you can use a recall step to bring your measured data into the memory list.

Now we have our correction curve loaded into the Memory List, we can use this curve to overwrite the calibrated device. Let’s open up the calibration window, and we’ll select the ‘copy from memory list’ button and choose our source curve. You can either apply the curve as it is, or invert it using this “invert curve” checkbox. You would use this, for example, if you want to remove the frequency response curve of the microphone from your measurement.

So, let’s check that box, and we’ll hit “apply” to save it, and OK.

Now we’ve added the appropriate correction curve to the signal path, the final step is to apply this new correction to our input response by enabling the checkbox “Apply Correction In” in the analysis step. It’s important to make sure this is selected otherwise, the correction will not be applied.

https://www.listeninc.com/wp/media/2025/11/Correction-Curves-Blog-TN.png 1080 1080 Julius Wijono https://www.listeninc.com/wp/media/logo.png Julius Wijono2025-11-25 05:00:562026-08-27 14:03:06Importing Correction Curves for Calibration

Calculating Intersection Times with SoundCheck

November 11, 2025/in Blog, SoundCheck Tips Videos/by Julius Wijono

Find the start and stop times of any recorded signal with SoundCheck’s intersection post-processing step. In this video, we’ll show you how to define a threshold, locate where your waveform crosses it, and calculate timing for applications like wake-word latency or response detection.

Additional Resources for SoundCheck

Detailed explanations of how to use SoundCheck can be found in the SoundCheck manual.

Video Transcript: Calculating Intersection Times with SoundCheck

In this video, I’ll show you how to find the start time of a recording. 

Here I have a sequence which recalls a wave file. I’m using the ITU real speech wave file which is provided with SoundCheck as an example. 

I’ll apply the recall step, and now we have the waveform in the memory list. 

Let’s say I want to find the start time of this waveform, which is around 0.5 seconds. 

We can do this with an intersection post-processing step, but first I need to define a signal level or a threshold. 

We need to select a value that is above the noise floor but within the signal of the recording you’re using. Most of the signal in this waveform lies above 30 m FS, so I’ll use 30 mFS. This means SoundCheck will find the point where the waveform crosses the 30 mFs value. 

Once this value is defined, I use an intersection post-processing step. I select the wave file or the recording as my operand A and the signal level that I have defined as operand B. 

We’ll use the “search up”  option, which starts at the beginning of operand A, which is the recording, and finds the point where it intersects with the signal level. 

“Search down” would do it the other way, and “return all intersection points” will identify all points at which the waveform corresponds to the signal level. 

Now let’s run the sequence, and we get the start time as a value, which is 492 milliseconds, approximately 0.5 seconds as we saw in the waveform graph. 

This is a simple example of how to calculate the start time.  This could be used, for example, for measuring the latency of a response to a wake word. If you wanted to find the stop time, you could use the “search down” function in the intersection step, and you could even calculate waveform duration by subtracting the start time from the stop time.

https://www.listeninc.com/wp/media/2025/11/Intersection-Times-Blog-TN.png 1080 1080 Julius Wijono https://www.listeninc.com/wp/media/logo.png Julius Wijono2025-11-11 05:00:252026-08-27 14:04:49Calculating Intersection Times with SoundCheck

ANC Headphones Audio Measurement

November 4, 2025/in Audio Measurement Videos, Blog, Headphone & Headset Videos/by Julius Wijono

How do you measure ANC headphones? In this video, we show how to measure active noise cancellation (ANC) performance using SoundCheck. You’ll learn how to test unoccluded, passive, and active responses with a head and torso simulator (HATS), an AmpConnect 621 audio interface, a SoundConnect 2 power supply, and pink noise source to calculate total noise attenuation. This simple setup can also be expanded for real-time ANC analysis or used to measure THD and distortion caused by ANC circuits.

Watch this Video Demo of Measuring ANC Headphones

Learn More about ANC Sequences

    • Noise-Cancelling Headphones Test Sequence: https://www.listeninc.com/products/test-sequences/free/noise-cancelling-headphones-test-sequence/

Video Transcript: How to Measure ANC Headphones

Today I’m going to show you how to measure active noise cancellation performance, or ANC, of headphones.

The set-up is simple. I’m using SoundCheck to generate the test signals and analyze the results. I have a head and torso simulator to capture the ear’s response. I’m using an AmpConnect 621 audio interface which also provides amplification for the speaker… and I have a SoundConnect 2 microphone power supply to power the mics in the head and torso simulator. If I was using a newer HATS with IEPE mics, I wouldn’t need this – I could power it directly from the AmpConnect. I’ve got a basic speaker here to generate the pink noise that we’ll use to measure the noise cancellation, and I have a nice pair of noise-canceling headphones.

We’ll play pink noise from this speaker. First we’ll measure the unoccluded ear response, then the passive response. That’s with the headphones on the ear but not turned on. Then we’ll turn on the ANC and measure the total attenuation – the full effect of the active and passive isolation.

Let’s run our test sequence. First we’ll take the unoccluded measurement without headphones. You’ll hear the pink noise playing, and we’ll see our measurement on the graph.

There we go…

Now the sequence pauses while we put the headphones on.

Next we’ll play the pink noise. I’m going to adjust the headphones to establish a good seal. Typically you would make this measurement 5 times and average it to account for variation in fit, but I’m just going to do it once in this demo.

Now let’s continue.  [pink noise plays]

So now we have the occluded measurement – that’s telling us how much sound the headphones are passively attenuating just from their materials and geometry.

Now we’re going to turn on the ANC and let the sequence continue….

Here we have the measurement with ANC turned on.

And you can see on the top graph here, we show the sound pressure level for the unoccluded measurement, the occluded measurement, and the measurement with ANC turned on. And this bottom graph here uses a simple calculation to show the passive, active, and total noise attenuation of the headphone.

That’s the test in its simplest form. You can get more fancy with your speaker setup. For example, instead of using just one source speaker, you could use multiple equalized source speakers to create a more realistic spatial background noise environment. You could also measure both ears at the same time. If you do this, you can use SoundChecks multichannel RTA to check for fit – you just measure the two channels simultaneously and make sure the left and right are showing similar responses. This saves time as you don’t need to make multiple measurements.

You could also use the multichannel RTA to look at how noise attenuation changes in real time. You’d need an external reference measurement microphone positioned here, outside the headphone, and you could play complex signals, like real recorded background noise from an airplane and watch in real time how the noise attenuation changes. This gives a more realistic representation of how the ANC circuit responds to dynamic signals.  

This set up is good for much more than just measuring active noise cancellations. We’ve done a lot of research on audio distortion caused by active noise cancellation. With the same setup, but different test sequences, you can measure THD, intermodulation distortion, time-variant distortion and more. Check out the technical papers on our website to learn more.

https://www.listeninc.com/wp/media/2025/11/ANC-Headphones-TN-scaled.png 1440 2560 Julius Wijono https://www.listeninc.com/wp/media/logo.png Julius Wijono2025-11-04 05:00:072026-08-27 15:09:51ANC Headphones Audio Measurement

Detecting Air Leaks with SoundCheck

October 28, 2025/in Blog, SoundCheck Tips Videos/by Julius Wijono

Detect loudspeaker air leaks automatically with SoundCheck’s advanced analysis tools! In this video, we’ll show you how to use THD, Rub & Buzz, ePRB, eLP, and Crest Factor measurements to identify air leaks and port noise – no human listening required.

Additional Resources for SoundCheck

Detailed explanations of how to use SoundCheck can be found in the SoundCheck manual.

Video Transcript: Detecting Air Leaks with SoundCheck

Traditionally, loudspeaker enclosure air leaks are detected by human listeners during the final test process. SoundCheck’s algorithms can detect air leaks and characterize port noise automatically. Let’s take a look.

I’ve made recordings of a closed box speaker system with and without an audible air leak using a 60 Hz sinewave.  Let’s listen to them. First without the leak <play wav file> and then with the leak <play wav file>.  Looking at these two recordings in real time on a spectrum analyzer, we can see the spectrum of the speaker with the air leak has significantly higher harmonic content than the one without, particularly the odd order harmonics.

Now, let’s take a look at the SoundCheck algorithms that can detect the air leak. For these demos, I’ll recall previously saved waveforms for analysis. 

First, we’ll establish a baseline using a speaker without a leak.  We’re going to look at  THD, Rub & Buzz, enhanced Perceptual Rub & Buzz or ePRB, Enhanced Loose Particle detection or eLP and Crest Factor.

This display shows us these results, displayed on different graphs. As you would expect for a good speaker, THD, Rub & Buzz and Crest Factor are low, ePRB is below audible levels and there are no eLP events detected.

Now let’s analyze a recording where I’ve introduced an air leak by loosening the screws that secure the front baffle to the rear enclosure. THD and Rub & Buzz are significantly higher, ePRB is well above the audibility threshold of 12 phons and hundreds of eLP events have been detected.

These measurements were made with a microphone pointing at the side of the enclosure, the actual location of the airleak.  If we next analyze the results of the same sweep captured by an on-axis microphone, we’ll see that there is a much smaller delta between the leak and no leak data. 

Configuring pass/fail limits for any of these metrics is much easier using the side mic data so you can see that microphone location is critical for leak detection. If leaks are commonly coming from the front baffle, then a single, on-axis mic should detect them but if the leaks are coming from the back or sides of the enclosure, two or more microphones should be deployed. The good news is if you are doing this on a production line, although you need an extra microphone, the measurement can be made simultaneously with your other QC measurements.

It should be noted that this method may also pick up defects from other causes, but if you’re using it to reject faulty speakers, then that doesn’t really matter. 

These techniques can also be used in R&D for the characterization of port noise, allowing you to compare the results using ports of different shapes and sizes. 

Some of these methods may work better than others on your specific design so I’d recommend that you evaluate all of them with your own products, and focus on those that yield the most reliable results. 

https://www.listeninc.com/wp/media/2025/10/Air-Leak-Blog-TN-1.png 1080 1080 Julius Wijono https://www.listeninc.com/wp/media/logo.png Julius Wijono2025-10-28 05:00:552026-08-27 13:47:51Detecting Air Leaks with SoundCheck

Using SoundCheck’s Multi-Instrument FFT/RTA/Oscilloscope

October 14, 2025/in Blog, SoundCheck Tips Videos/by Julius Wijono

Visualize your measurements in real time with SoundCheck’s Multi-Instrument feature! In this video, we’ll show you how to use the integrated FFT analyzer, RTA, and oscilloscope to view synchronized time and frequency data, perform live calculations, and save custom instrument setups for quick recall.

Additional Resources for SoundCheck

Detailed explanations of how to use SoundCheck can be found in the SoundCheck manual.

Video Transcript: Using SoundCheck’s Multi-Instrument FFT/RTA/Oscilloscope

SoundCheck features a multi-channel Real Time spectrum analyzer, FFT Spectrum analyzer and Oscilloscope integrated into a single “multi-instrument”. This lets you view any number of live waveforms simultaneously, and results can be time-synchronized across the three instruments to simultaneously display parameters in both the time and frequency domain. Let’s check it out.

All three instruments can be opened from the instrument menu or with keyboard shortcuts which opens them with their default settings. Let’s open the FFT Spectrum analyzer. 

On the left is the control panel and next to it is the graph where the live curves are displayed. Live curves are also shown in the Memory List and identified with a green dot. The multi instrument graph is identified by its white shading around the plot area but otherwise, it has the same functions as the standard graphs used in SoundCheck display steps.

The acquisition controls are at the top of the control panel. The Record and Stop buttons are used to start and stop measurements, and when the instrument is in linear mode, the Continue button resumes the previous linear measurement and continues until the Start button is next used. The Add button lets us add new instruments, calculations, graphs and triggers to the multi instrument.

Let’s first open up the FFT Spectrum Analyzer and look at some of the analysis options for stationary signals such as sinewaves.

I’m outputting a 1 kHz tone at 2 Vrms from the signal generator. On the Multi-instrument graph, we can clearly see the fundamental and the 2nd and 3rd harmonics. Let’s drop a cursor on the fundamental using the snap to max function, enable the harmonic cursor and by exposing the advanced graph controls, we can get a real time readout of the cursor frequency, level and the THD of the fundamental. 

Now, let’s add a calculation, in this case a real-time masking curve which will show us how our dominant fundamental tone is masking other stationary signals. The masking curve suggests that all of the harmonics are below the threshold of hearing but as we increase the signal level, they get closer to being audible.  

By adding a second signal generator, we can view intermodulation products. One generator is set to 340 Hz and the other to  7 kHz with a 4:1 amplitude ratio between the two signals. With these settings, we can clearly see the intermodulation products around the 7 kHz tone.

I can save any virtual instrument configuration for later recall from the instruments menu. Let’s just ‘close all’ to close all my windows. And now I can re-open it without having to reopen and configure all of the individual instruments again. 

Let’s switch over to a saved configuration with the RTA and signal generator and look at some of the other calculation options. The Multi-Instrument graph supports both live curves from the RTA and static curves from the memory list, and can use them both in a calculation. 

Here, I’m sending a Pink Noise stimulus to the device under test and I want to compare its RTA spectrum to a target response curve, which is already in the Memory List.  I can  just drag the target curve over from the Memory List to display it on the live graph. Now, I add a calculation for dB subtraction where the live RTA curve is Operand A and the Target Curve from the Memory List is Operand B. This generates a real time difference curve on my live graph and I can name it something more descriptive. 

Another useful RTA calculation is Power Averaging.  Let’s add a couple of RTA’s to the current configuration and assign each a unique microphone signal path.  Notice how, when I add RTAs, they inherit the properties of the original RTA so all I have to do is update the Signal Path assignment. Now I can add the Power Average calculation, select all three microphones and we have the Power Average of the three microphones. Live curves can always be saved to the Memory List by clicking the Save to Memory button. Once there, they can be displayed on other graphs or saved to disc. Other available calculations include Maximum, Minimum and dB addition.

Let’s take a look at the oscilloscope. I’ll open a saved virtual instrument that is configured with two oscilloscopes, monitoring two different input signal paths. The oscilloscope control panel lets us set the data name, signal path selection, time base and measurement mode.  The measuring indicator is bright green when the instrument is active and dark green when stopped.

Now let’s pause the signal generators and add a trigger.  Our trigger level is set relative to the signal’s peak level using either linear or logarithmic scaling. Slope selection lets the user decide whether the scope will trigger on the first positive or negative portion of the incoming signal and offset allows you to define the amount of time that the Acquired Signal is shifted, relative to the point at which it is triggered.

The trigger level is set to 300 millivolts on Direct Input 5 so let’s start the signal generators and increase the signal level, and once we exceed the trigger threshold we can see how the scope starts running and when the signal goes below the trigger threshold it stops.

I hope you’ve learned a few things about the multi-instrument from this quick tip. Try it out for yourself, and don’t forget to check the user manual for more details.

https://www.listeninc.com/wp/media/2025/10/Multi-Instruments-Blog-TN.png 1080 1080 Julius Wijono https://www.listeninc.com/wp/media/logo.png Julius Wijono2025-10-14 06:00:452026-08-27 14:08:37Using SoundCheck’s Multi-Instrument FFT/RTA/Oscilloscope

SoundCheck Sequence Editor Secrets

September 16, 2025/in Blog, SoundCheck Tips Videos/by Julius Wijono

Speed up your SoundCheck sequence development with hidden Sequence Editor features. In this video, we’ll show you secret tips for editing, debugging, and reusing steps to streamline sequence development.

Additional Resources for SoundCheck

Detailed explanations of how to use SoundCheck can be found in the SoundCheck manual.

Video Transcript: SoundCheck Sequence Editor Secrets

In this short video, I’m going to show you how to speed up your sequence development with some of the hidden features in SoundCheck’s powerful sequence editor. 

The sequence editor can be opened from the Setup menu or with the Ctrl + Q keyboard shortcut.

On the left side is our template library. You can drag the divider to re-size it, or click the divider to show or hide elements.

Step templates are grouped by category, and you can click on the expansion buttons to expand or contract them. You can right click on the category name to create new templates or import them from other versions of SoundCheck. Existing templates can also be edited, renamed or deleted. All sequences located in the folder of the active sequence are listed in the sequence template group.

The right side of the editor contains the active sequence.  The configuration menu at the top is where you set the default behavior for when the sequence opens, starts and runs, and set the path to any instruction files. There’s also a comment field where you can enter notes about the sequence.

The Sequence Parameters table is used to create Memory List placeholders which can be filled via external control using the MemoryList.set TCP/IP command. 

Lastly, the Metadata table is used to configure the sequence’s Metadata parameters.

Expanding a step shows you what data is coming in and out of the step. Steps are added to a sequence by dragging from the template library and dropping at the desired location. They can be configured as desired. A step or groups of steps can be moved within a sequence using drag and drop.

Now let’s take a look at the features in the right click menu.

Right clicking > Configure Step lets you configure step logic such as looping and jumping, as well as adding breakpoints and comment lines.

The configure Script option is only active for custom steps, where the script configuration window offers access to the LabView and Python options as well as the custom step editor

Commenting lets you enter descriptive text to help others understand what’s going on, step by step, and it’s a very useful feature, especially where your sequences are long or complex. In this sequence we’ve used comment steps to describe individual step functions and comment lines to explain where different river measurements take place for a 3-way loudspeaker.

Insert and Replace step are self explanatory. Insert is an alternative to drag and drop, and ‘replace’ replaces an existing step with a new step from the template library.

Copy and paste is a new feature we introduced in SC23. You can either use the right click menu or control+C control+V keyboard shortcuts.

Remove – as the same suggests, it removes or deletes the step 

Rename – lets you change the default name to something more descriptive

Undo – lets you undo the last several actions including inserting, removing and editing steps

Expand/Collapse all is a global command that expands and collapses all steps in the sequence. and is useful for determining where certain inputs and outputs are happening during the sequence run.

We also have some powerful tools for sequence debugging and editing.

Breakpoints are really useful when you’re working on long or complex sequences. You can define points in the sequence where it breaks from running, then use the toolbar buttons to either advance to the next step or the end of the section. This lets you isolate and run  small parts of the sequence without having to run the entire sequence. Here I’ll add 4 breakpoints. Now I can run the sequence just up to the first break by clicking start on the toolbar. And I can use this button to step through the sequence one line at a time, this button to run to the next breakpoint or hit the abort button to end the sequence.

Another useful debugging feature we recently introduced is Enable Disable step. This is much like commenting out a line of code in a program – when the sequence runs, the disabled step will be skipped over until it is enabled again. You might, for example, disable an autosave step to avoid collecting data, or operator message steps to save time, when developing a sequence.

Run from here allows you to start the sequence from any point, and when you use this in combination with breakpoints, it can make your sequence development a lot faster. 

Apply is the last menu item. This simply allows you to apply the step function without having to open the step editor to click the editor’s apply button.

The last feature I want to show you is back over in the Template Library in the Sequence group.  I  can highlight a step or any number of steps from another sequence and drag them right into my active sequence. This is a big time saver whenever you want to repurpose part of an existing sequence. You can even go one step further and drag the entire sequence into your existing sequence, instantly creating a subsequence.

That concludes our sequence editor tips and tricks. Hopefully you learned something new, and don’t forget to check out the user manual for more details.

https://www.listeninc.com/wp/media/2025/09/Sequence-Editor-Secrets-Blog-TN.png 1080 1080 Julius Wijono https://www.listeninc.com/wp/media/logo.png Julius Wijono2025-09-16 10:49:232026-08-27 14:10:59SoundCheck Sequence Editor Secrets
Page 2 of 22‹1234›»

Audio Measurement Expertise


How Changing Industry Needs are Shaping Audio Test and Measurement

Smarter SoundCheck Sequences with Loops and Logic

Audio Basics: Polarity

How to Measure: Haptics

The Value of Big Data

Audio Basics: Phase Response

view all

Latest News


2026 End Of Year Promotions

Celebrating 30 years: Listening – The Secret Of Our Success

Automotive Test Sequence Including BSR, Max SPL and Frequency Response

Listen Introduces AudioConnect 2, a New Portable Dual-Channel Audio Interface

SoundCheck 21 Brings Enhanced Loose Particle Detection, Multichannel FFT, Metadata, Sequence Protection and more


Audio Measurement Expertise – Delivered Monthly

 

ABOUT LISTEN INC

Listen is a global leader in audio measurement and analysis, with over 30 years’ experience developing innovative test methods and algorithms. SoundCheck, our powerful software-based audio analyzer, pairs with our test interfaces, precision microphones, and accessories to offer a complete solution for testing loudspeakers, headphones, microphones, smart devices, communication systems, hearing aids, automotive audio, and more. Trusted by engineers worldwide, Listen delivers the accuracy and flexibility essential for modern audio testing, from the R&D lab to the production line.

PRODUCTS
APPLICATIONS
SUPPORT
RESOURCES
NEWS & EVENTS
ABOUT

CONNECT

YouTube
LinkedIn
LinkedIn
Share
Instagram

Copyright © Listen, Inc.   |   Privacy Policy   |   AI Disclosure
  • Instagram
  • LinkedIn
  • Youtube
  • Mail
Scroll to top