Registration required

The content you have requested is available only to registered visitors. Please complete the short form below (all fields are required).

  • 简体中文 简体中文 Chinese (Simplified) zh-hans
  • English English English en
Listen, Inc.
  • Products
    • AUDIO MEASUREMENT
    • System Overview
      • What Soundcheck Measures
      • SoundCheck for R&D
      • SoundCheck for Production
      • Innovation
    • SoundCheck Software
      • Making Measurements
      • Algorithm Highlights
      • Integration
      • What’s New?
      • Packages, Modules & Pricing
      • Support Contracts
    • Audio Measurement Interfaces
      • AudioConnect 2 (2 channel))
      • AmpConnect 621 (6/2 channels)
      • AudioConnect 8×8 (8 channel)
      • AudioConnect 6×2 (6/2 channel)
      • AmpConnect ISC (2 channel)
      • 3rd Party Audio Interfaces
    • Audio Testing Hardware
      • Microphones & Amplifiers
        • Measurement Microphones
        • Microphone Power
        • Audio Test Amplifier
      • Specialist Test Interfaces
        • Bluetooth Audio Measurement Interfaces
        • MEMS microphone Interfaces
        • DC Connect
      • Audio Test Accessories
        • Turntables
        • Halo Automotive 6-Mic Array
        • Automotive Audio Test Kit
        • The SCC-1 Ear Coupler
        • Other Measurement Transducers
        • Impedance Box
        • Calibrators
    • NOISE & VIBRATION MEASUREMENT
    • System Overview
    • NoiseCheck Software
    • Noise & Vibration Interfaces
    • Noise and Vibration Testing Hardware
  • Applications
    • Headphones & Headsets
    • Loudspeakers & Microspeakers
    • Microphones
    • Automotive
    • Communications
    • Smart Devices
    • Hearing Aids
    • Audio Electronics
  • Support
    • Get Support
    • User Documentation
    • Knowledgebase
    • Training
    • Sequences & Resources
    • Drivers
    • Register Product
    • Report a Bug / Request a Feature
  • Resources
    • ‘Sound Matters’ Blog: Audio Measurement Expertise
    • Test Sequences
    • Article Reprints
    • Published Papers
    • Technical Notes
    • Measurement Services
    • Useful References
  • News & Events
    • News
    • Events
  • About Listen
    • Listen, Inc.
    • Contact
    • Distributors & Reps
    • Careers
    • Privacy Policy
  • Menu Menu

all videos

Smart Glasses Audio Measurement

September 9, 2025/in Audio Measurement Videos, Blog, Smart Device Videos/by Julius Wijono

How do you measure smart glasses audio? In this video, we demonstrate how to test smart glasses using SoundCheck with a head and torso simulator and Bluetooth interface. You’ll see how to measure speaker frequency response, total harmonic distortion (THD), and left/right balance, as well as how to evaluate the built-in microphone using hands-free profile (HFP) measurements. This simple method can be applied to smart glasses, AR/VR headsets, or any Bluetooth device with speakers and microphones.

Watch this Video Demo of Measuring Smart Glasses Audio

Learn More about How to Perform Smart Glasses Sequences

  • Smart Glasses Speaker Output Test Sequence: https://www.listeninc.com/products/test-sequences/free/smart-glasses-speaker-output-test/
  • Smart Glasses Mic Input Test Sequence: https://www.listeninc.com/products/test-sequences/free/smart-glasses-mic-input-test/

Video Transcript: How to Measure Smart Glasses

It’s easy to make audio measurements on smart glasses using SoundCheck. Let me show you how.  As you probably know, most smart glasses and VR/AR headsets contain small speakers, usually embedded in the arms close to the ears. They also have microphones also hidden in the frames. This means we can make audio measurements on smart glasses pretty much the same way we do with a Bluetooth headset. 

Let’s start with our setup. You need a head and torso simulator, or at least a test head. This lets you position the glasses as they would be worn in real life, and record the sound at the ears. If you want to measure the microphone as well as the speakers, you’ll need one that includes a mouth. Alongside this, we’ll use an AmpConnect 621 audio interface. This transmits the signal from the microphones into the laptop, which is running SoundCheck, and it also provides amplifier output to power the HATS mouth. We’re also going to need a SoundConnect 2 microphone power supply because I’m using an older HATS that needs 200 Volts polarization power. If you have a newer version you can power it directly from the 621. And I’m going to use a BQC bluetooth interface to communicate with the smart glasses.

We’ll use two basic test sequences that you can download from our website. Let’s run the sequence and take a look at the results, then I’ll explain what we’re doing.

First the sequence is prompting me to pair my device. I’ll put it in pairing mode and say ‘yes’.

We can see it in the list here…

Now it’s telling me to put the smart glasses on the head and torso simulator… lets do that

And we’re ready to make our measurement so I’ll hit enter to continue

That was the test signal, a Stweep, which is a special type of stepped sine wave.

Now we can see our results. On the top graphs we have the left and right frequency response – you can see they are pretty well matched. The response is rolling off quite a bit in the low end, so anything below about 500Hz in all of these measurements will be very noisy.

Here we have the total harmonic distortion of both the left and right speakers..

And down here at the bottom we have the left/right balance which you can see is pretty flat up to about 8kHz. Above this, we see some discrepancy as the responses of both ears have more peaks and dips.. This is very sensitive to positioning, so it’s important to make sure the glasses are correctly positioned on the head. It’s also good to make multiple measurements, completely removing and replacing the glasses to see how the balance changes.

Now let’s take a look at the sequence and I’ll show you what we did.

We start with our stimulus step, which is configured to sweep from 20kHz to 100Hz. Then we have some message steps – that’s where it was prompting us if we wanted to pair the glasses using Bluetooth and confirm once it was paired and placed on HATS. Then you can see we play the stimulus and record the response.

Now we have some post-processing going on. Because the Bluetooth output and AmpConnect input don’t use the same master clock for sampling,  we have to resample and frequency shift so that the stimulus and response are aligned for analysis. I’m not sure if you heard the short tone at the beginning of the test signal –  that was a ‘trigger tone’ that lets SoundCheck precisely align the waveforms by playing a signal within the pass band of the device. Once we’ve done this, we can run our Harmonictrak analysis to calculate frequency response and distortion, and also another post-processing step to calculate the left/right balance. Finally, we have a display step that shows all these results on screen.

These smart glasses also feature a microphone for making calls and recording, so let’s now measure that. We’ll use exactly the same setup with a different sequence. This time we’re going to play the stimulus from the mouth, and capture the recording using the microphone.

Let’s run the test… 

We’re pairing it again and we’re switching the Bluetooth profile to HFP – hands-free profile as this is what you’d typically use for making calls. We made the speaker measurement using the A2DP profile as that’s what you would typically use listening to music.

Now it’s going to play the test signal… and output the frequency response… and we can see it’s pretty uniform  from about 300 Hz to about 7k or so,   then it rolls off.

Let’s look at the sequence to see what we did here. 

Here we have our stimulus, sweeping from 8kHz down to 100Hz, which aligns with the HFP Bluetooth profile that we’re using for this measurement.

We have our message steps, the same as before, to connect via Bluetooth 

And here we have our stimulus and acquisition step, you can see we’re playing out the mouth simulator.

And after we’ve done our frequency shift and resampling, we calculate the frequency response of the microphone  and display that on the graph.

So, as you can see, testing smart glasses using SoundCheck is quick and easy – just a couple of minutes to run the tests. And these are pretty basic tests – if you want more extensive measurements you can simply modify the sequence to add any other results that you want. With a little extra equipment, you could also make measurements with background noise, or make audio leakage measurements. You can download these test sequences for free on our website, and they’ll work with any bluetooth device with a speaker and microphone so not just smart glasses but headsets, VR and AR goggles etc.. Check it out, and call us if you have any questions.

https://www.listeninc.com/wp/media/2025/09/Smart-Glasses-Demo-TN.png 1080 1920 Julius Wijono https://www.listeninc.com/wp/media/logo.png Julius Wijono2025-09-09 14:29:432026-08-28 14:33:38Smart Glasses Audio Measurement

Creating Custom Python Steps in SoundCheck

September 3, 2025/in Blog, SoundCheck Tips Videos/by Julius Wijono

Bring your own functions into SoundCheck with custom Python steps! In this video, we’ll show you how to create and run a simple script, then integrate it into a SoundCheck sequence for powerful custom calculations without LabVIEW programming.

Additional Resources for SoundCheck

Detailed explanations of how to use SoundCheck can be found in the SoundCheck manual.

Video Transcript: Creating Custom Python Steps in SoundCheck

Python custom steps let you bring your own custom functions into SoundCheck without needing any LabVIEW programming knowledge. Let me show you how. 

I’m going to assume you already have the optional Python Custom Step module – that’s part number 2042 – installed and that you have already installed and configured Python with SoundCheck on your computer following the instructions in the SoundCheck user manual.

For this demo, I’m just going to create a very basic equation so that you can easily see how we’re handling the inputs and outputs, but the same principles apply whatever calculation you are working with.

Here I have a simple Python script I wrote called “square a value” which will make Soundcheck take the data values that you input and square them.

There is an editor configuration section which shows you how to define inputs and outputs and any parameters. In this case I have a ‘value in’ which is coming from SoundCheck which will be processed by this step. It’s just taking the value in the y data of the value in multiplying it by itself and then pushing it out as value out.

Now let’s see how this works inside Soundcheck. 

I’ll create a new sequence. Let me create a new custom step by right clicking on Custom, then New…, name the step “Square a value”. After entering the name, I’ll change the custom step type to Python and set the script path to my ‘square a value’ script that I just showed you. This “square a value” step now appears under Custom and I can drag this into my SoundCheck sequence. Once this has been added to the sequence, I can also Right Click > Configure Script to change my script path.

Now I’ll create an operator numeric step above the step which will ask the user to enter a value. I’ll call this original value, and I’m going to set the default value as five.

You’ll see the original value is in the memory list, and if I apply the step, the original value is populated on the y-axis with a value of five.

Now I’ll open my custom Python step.
We can see the step editor window, and you can see the value in and value out parameters. The value in has been auto selected but this can be changed if you have multiple input variables.

Now I’ll set my memory list name for the value out as “squared number”. This sends the “value in” parameter – my original value – from Soundcheck to the Python script we made earlier. The script now multiplies that value by itself, and outputs the result as “value out” which comes back into sound check as the squared number.

Let’s run the sequence.
We have our original value of five… and the result, our squared number as 25.

This is a very simple example, but it’s easily extended to more complex calculations, or configured with an existing Python library of custom calculations. Check out the SoundCheck manual for more information.

https://www.listeninc.com/wp/media/2025/08/Custom-Python-Steps-Blog-TN.png 1080 1080 Julius Wijono https://www.listeninc.com/wp/media/logo.png Julius Wijono2025-09-03 10:04:532026-08-27 14:04:13Creating Custom Python Steps in SoundCheck

Using Statistics Across Multiple Signal Paths

August 19, 2025/in Blog, SoundCheck Tips Videos/by Julius Wijono

Run advanced statistics directly in your sequences with SoundCheck 23! In this video, we’ll show you how to apply statistical analysis across multiple signal paths, like microphone arrays, using new offline statistics features. Learn how to calculate mean, median, deviation, best/worst fit, and more.

Additional Resources for SoundCheck

Detailed explanations of how to use SoundCheck can be found in the SoundCheck manual.

Video Transcript: Using Statistics Across Multiple Signal Paths

The offline statistics mode is a new option which allows statistical functions previously available only from the offline menu to be used in a sequence.

Today I’m going to show you  how to use SoundCheck’s advanced options to run statistics across multiple signal paths within a sequence. This is something new we added in SoundCheck 23, so if you’re using an older version, you’ll need to upgrade to use this feature.

Here I have a six microphone array, and I want to run statistics across all 6 mics.

Let’s take a look at the statistics step from my sequence here…

There’s a couple of new features in statistics.

You can now apply a search range to eliminate certain ranges from your statistical analysis. Let’s exclude the low frequency points that might be outside the range of the speaker… let’s just do that now… I’ll set it from 80Hz to 20k.

Another useful new feature is that you can now drag and drop curves and groups of curves from the memory list, so here, I’ll bring over the group of responses from my six microphones.

Now, if you are more familiar with our older versions, you’ll notice that I now have a new option,  “offline analysis” available right here in the step editor. This is all the statistics functionality that used to only be available offline in earlier versions, but now you can run it in a sequence. Let’s select this…Now you can see the median function appears on the statistics tab and the distribution tab is enabled, giving us access to the best fit and worst fit options and histogram output. You can also apply a custom name to your statistical data. We’ll have it run a full set of statistics including maximum, minimum and mean, standard deviation, median and best fit to average.

Offline statistics resets after each sequence run, so that rather than running across sequential sequence measurements. It will run across responses acquired from multiple signal paths, such as a microphone array.

I already dragged over the RTA responses for the six microphones, so l et’s run the sequence and see how it processes the data.

On the upper left we have the RTA spectrums from the six mic array. The bottom left is the maximum, minimum, and mean. 

Here on the upper right we have the plus and minus three sigma and median curves. And the bottom right are the best and worst fit to average curves. We can see that the best fit is the RTA spectrum from mic 4 and the worst fit is from mic 1.

Also remember that we applied a 80 to 20k search range to the analysis, to exclude the low frequency portions of the RTA curves that are outside the operating range of the speaker so they don’t influence the statistics results.

The statistics module is included in all SoundCheck configuration packages, so if you have SoundCheck 23, check it out!

https://www.listeninc.com/wp/media/2025/08/Using-Statistics-Across-Multiple-Signal-Paths-Blog-TN.png 1080 1080 Julius Wijono https://www.listeninc.com/wp/media/logo.png Julius Wijono2025-08-19 12:08:372026-08-27 14:12:49Using Statistics Across Multiple Signal Paths

Calculating Voltage for Target SPL

August 5, 2025/in Blog, SoundCheck Tips Videos/by Julius Wijono

Want to measure your speaker at a specific SPL but not sure what voltage to use? In this video, we’ll show you how to calculate the exact test voltage needed to hit your target SPL using a simple SoundCheck sequence.

Additional Resources for SoundCheck

Detailed explanations of how to use SoundCheck can be found in the SoundCheck manual.

Pre-written test sequence to calculate the voltage level for a target SPL. You can modify it to meet your needs or incorporate the steps into your own test sequence.

Video Transcript: Calculating Voltage for Target SPL

In an earlier video, I demonstrated how you can increment the test voltage level to see the frequency responses at various levels. But what if you want to run a speaker measurement at a specific sound pressure level and need to know what test voltage level to use? 

I’ve written a short SoundCheck sequence to do this – let’s take a look.

First, the  sequence asks the user to enter the desired target level in dB SPL. I’ll put 94dB as an example. It plays through a 1kHz sine tone and calculates the sensitivity, then  implements a post-processing step to obtain the voltage level needed to output 94dB at 1kHz. The sequence then displays the calculated voltage level and the sensitivity level. 

The rest of the sequence verifies this by running a stepped sine sweep using the calculated voltage level and outputting the frequency response. You will notice that at the 1kHz mark, it reflects the target level I input earlier, which is 94dB SPL. 

This demo sequence can be downloaded from our website if you want to try incorporating it into your measurement sequences. Check it out, and if you have questions, please contact the Listen Support team.

https://www.listeninc.com/wp/media/2025/08/Calculating-Voltage-for-Target-SPL-Blog-TN.png 1080 1080 Julius Wijono https://www.listeninc.com/wp/media/logo.png Julius Wijono2025-08-05 07:00:022026-08-27 14:10:26Calculating Voltage for Target SPL

Car Audio Measurement – Part Two

July 29, 2025/in Audio Measurement Videos, Automotive Videos, Blog automotive audio, automotive audio demo, automotive audio measurement, automotive audio test, car audio, car audio demo, car audio measurement, car audio measurements, car audio test, car measurement, how to measure automotive audio, how to measure automotive audio part two, how to measure car audio, how to measure car audio - part two, listen demo, listen inc demo, listen inc measurements, soundcheck demo/by Julius Wijono

In this second part of our car audio measurement demo, we’ll be covering how to measure maximum SPL at the onset of audible distortion and detect impulsive distortion using advanced SoundCheck sequences. You’ll see how to identify buzz, squeak, and rattle with perceptual Rub & Buzz, transient distortion, and crest factor analysis.

Watch this Video Demo of Car Audio Measurement Techniques

Learn More about How to Perform Car Audio Measurements

Here are some additional resources:

  • Standardized Automotive Audio Testing Seminar: https://www.listeninc.com/standardized-automotive-audio-testing-seminar/
  • Automotive Audio Measurements Seminar (Frequency Response, Max SPL, Buzz, Squeak & Rattle): https://www.listeninc.com/automotive-audio-testing-seminar-2/
  • Standardized Automotive Audio Measurements (presented at ISEAT conference): https://www.listeninc.com/standardized-automotive-audio-measurements/

Video Transcript: How to Measure Car Audio – Part Two

Today, I’m going to continue on from our last automotive video where we measured frequency response, spectral uniformity, THD and IM distortion. This time we’ll  demonstrate Max SPL at the onset of audible distortion  and impulsive distortion. Let’s make some measurements.

Again, I’m using the test configuration recommended in the AES TC-AA white paper on automotive measurements. We’re using a precisely positioned 6-mic array in the driver’s seat to represent our listener. This is connected to  an AmpConnect 621 Audio Interface. Our laptop is also connected to a measurement-grade Bluetooth interface  which we’re using to send the stimulus signal into our car’s head unit. If you want to know more about the test configuration, you can download the AES white paper, and we also have full details on our website. The inputs and outputs of the test system are already calibrated, as is the  audio interface, so we’re ready to measure.

Maximum SPL is one of the measurements outlined in the TC-AA proposal, and it’s important because it lets you compare maximum sound levels of infotainment systems. It’s defined as the maximum sound pressure level that the infotainment system can reproduce, and it combines all the components of the system – the speakers, amplifiers, power supply and so on.

The simplest way of evaluating this is to measure the overall Max SPL and Max SPL spectrum regardless of distortion. In these tests we set the car’s volume control to maximum and measure overall Max SPL and SPL Spectrum simultaneously using a 30 second broadband 20 to 20 KHz monophonic pink noise stimulus at minus 12db FS . This is quite a basic measurement and I’ve demonstrated it in other videos, so we’ll just briefly discuss the results here, then I’ll demo a more advanced measurement. 

Here we see the individual microphone measurements and the average, the black line. The overall level of 103dBC, regardless of distortion, isn’t too loud but maybe it might be limited by design to prevent severe distortion at low frequencies from clipping the amplifier. 

What I’ll show you now is a Maximum SPL measurement at the onset of audible distortion. More volume is only good as long as the output sounds clean, so it makes sense to define the Maximum SPL based on when the sound quality starts to degrade.

This is a more complex test sequence and takes longer to run because you need to repeatedly play the stimulus until you reach distortion across a range of frequencies – similar to how we measure Max SPL in other applications. The good news is that this process can be highly automated in SoundCheck.

Our test sequence plays the stimulus multiple times for each test frequency, increasing the level in 3dB steps until the THD exceeds a predefined level in percent. It then reduces the level by 3dB and increases it in smaller increments of 0.5 dB to more precisely find the THD threshold. The Max SPL is recorded at that frequency and the test sequence continues to the next frequency. The entire process is completely automated via the test sequence, making this measurement fast with minimal intervention.

This sequence actually takes about 20 minutes to run in total, so I’ve edited this recording to skip the repetitive bits. We’ll set our range from 50 Hz up to 500 Hz, and we’ll set the percentage distortion. I’m going to set that at 3%. That means that once the distortion level goes above 3% it will record it and move onto the next frequency.

We’ll start at minus 12dB. The first thing it does is an auto range and it measures the time delay in the system… Now it’s playing 50 Hertz…It’s auto ranging. In a moment, it’s going to show the first result.

All right, here we go.

So, we can see the 50 Hertz sine wave of the 6 microphones capturing it, and we can see that we’re around 3.4% distortion.

So now it’s going to lower by 3 dB.

And it’s going to start going up again.

So now we’re 114 dB at 2.4%.

Now it’s going in half DB steps to very precisely find the sound pressure level at exactly 3%.

I’m just going to skip quickly through the next few measurements until we start graphing results

OK. We got 50, 63, and 80 Hz. You can see on the bottom graph is the input level and on the top graph we have the maximum sound pressure level versus frequency, the blue curve, and the orange curve is the THD level for that sound pressure level.

Again, I’ll fast-forward through the rest until we get our end result – it’s just more of the same at a bunch of different frequencies

OK, here’s our final result. The top graph shows the Maximum SPL and corresponding THD, and the lower graph shows the maximum stimulus level plotted when the THD reaches 3% with the head units’ volume control set to max.

At some frequencies, especially higher frequencies, for example 400 Hz and 500 Hz, the maximum input level is reached before the system distortion reaches 3% THD. The stimulus level is typically limited by the lower frequencies where there is more distortion.

So that’s it for system performance measurements. Now let’s look at system integrity.

Impulsive Distortion is a useful system integrity metric. It detects any audible buzz, squeak and rattle that may be caused by the speakers vibrating the door panels, loose wire harnesses, etc. These noises degrade the listener experience so it’s important to assess the vehicle thoroughly. It’s actually a good idea to make these measurements before you make the system characterization measurements, as this ensures that the infotainment system is properly installed in the vehicle under test

You can also use this test as an end-of-line check to verify vehicle integrity.

There are several methods of measuring impulsive distortion. The AES White Paper suggests a crest factor measurement with a logarithmic sine sweep and a tracking high pass filter, to evaluate impulsive distortion at 80 and 90 dBA. Sine waves have a crest factor of 3dB, and transients, such as rattling wires, loose fasteners, and noise, for example background noise, typically have a crest factor greater than 8dB. Generally speaking, crest factors over 3 dB, may indicate buzz, squeak or rattle. However, you have to be a bit careful as background noise, especially in a noisy factory, can result in similar Crest Factor results. You have to be very careful to minimize background noise and make sure that the results correlate with what you can hear.

I prefer to use perceptual Rub & Buzz and Transient distortion versus time instead, as they are less sensitive to background noise, and only highlight distortion sounds that are audible to humans. Perceptual Rub & Buzz uses masking curves to simulate the performance of the human ear to measure only audible distortion.  Transient distortion versus time measurement tracks individual events in the time domain to reveal any loose particles or rattling wires. It offers greater precision than frequency domain measurements since it tracks individual transient events.

I’ll measure both these parameters simultaneously, using a stepped sine sweep stimulus.

There’s a couple of frequencies there where I could hear some buzzing or rattling sound, I’m not sure if you could hear it. Let’s see if we pick that up in the measurement.

OK,  so here’s our recorded time waveform of all 6 mics.

And here… we can see the perceptual rub and buzz and indeed there’s a little bit of a peak going on at around 224 Hz and probably at a higher frequency here to around 340 Hz. These are the little buzzing sounds that we heard during the sweep.

Now, if we go to the bottom waveform graph, we can actually see if there’s any transients. Those are typically caused by things rattling around.

We don’t have much here – at low frequencies we don’t have a lot of output, so I suspect this is just background noise. So this car isn’t bad – just a little bit of Rub & Buzz and no transient artifacts.

I actually tried cranking the SPL up to 90dB to try to get some distortion at higher volumes, and here’s what I got…

Let’s just take a listen to the recorded response…. At this volume you can hear the distortion a lot more clearly.

Here we have the results of crest factor, Perceptual Rub & buzz and transient distortion.

The distortion is so obvious at this volume that it even shows up on the Crest Factor response – you can see the Crest Factor is above 8dB between 200 – 300 Hz.

It’s also much more obvious on the PRB curve – you can see a peak in the same point showing it correlates well. This is a little more sensitive than crest factor though –  we can also see a smaller, sharper bump at 600 Hz which is not perceptible using crest factor measurement, even though I could hear it during the sweep. This measurement technique is also considerably more reliable in a noisy environment.

This 3rd graph shows the time transients of the impulsive distortion measurement. You can see the constant background noise as a steady noise floor and impulsive distortion is highlighted as well-defined transient spikes. You can see transient spikes from 2 of the microphones around 11-12 seconds into the sweep. These are closer to the driver side door where a door panel is rattling at low frequencies, around 200-300 Hz, in the sine sweep. A neat trick with this measurement method is that you can actually listen to the recording without the fundamental, let me just play that back now… and that really highlights the audible distortion.

So that pretty much concludes our suite of measurements. There are of course many variations of these measurements as well as other things you could measure with the same physical hardware setup, but that’s all we have time for today. There are some more in-depth automotive audio testing videos on our website and YouTube channel, so if you want to learn more, check them out.

https://www.listeninc.com/wp/media/2025/07/Car-Audio-Demo-Part-Two-TN-scaled.png 1440 2560 Julius Wijono https://www.listeninc.com/wp/media/logo.png Julius Wijono2025-07-29 07:00:262026-08-28 14:26:17Car Audio Measurement – Part Two

Using Masking Curves for Measurement Insights

July 22, 2025/in Blog, SoundCheck Tips Videos/by Julius Wijono

Discover how masking curves in SoundCheck 23 bring psychoacoustics into your measurements with real-time tonal masking and threshold of hearing visualization – an industry first. In this video, we’ll show you how to use this new feature for production failure analysis and R&D insights by correlating what you see with what you hear.

Additional Resources for SoundCheck

Detailed explanations of how to use SoundCheck can be found in the SoundCheck manual.

Video Transcript: Using Masking Curves for Measurement Insights

A great new feature in SoundCheck 23 is the introduction of real-time tonal masking and threshold of hearing curves in the spectrum analyzer—an industry first. This lets you visualize how a dominant tone audibly masks other frequencies for a visual correlation between what we measure and what we hear. Let’s take a look at how to use it.

In production, it can give a deeper insight into failure analysis. Here, I have a small micro speaker. These designs are notorious for having rub and buzz problems around resonance due to their single-point suspensions. Let’s run our test sequence and examine the results.

The upper XY graph shows the fundamental and the enhanced perceptual Rub & Buzz (EPRB) curve. There’s a strong EPRB component focused right around 600 Hz. In the lower XY graph, we’re plotting the EPRB curve along with the electrical impedance curve, and we can see a strong correlation between the defect and the resonant frequency of the loudspeaker. On the waveform graph, zoomed in around 600 Hz, we can clearly see how distorted the waveform is.

Now, let’s use the masking curve tool to investigate this defect further. I’ll open up a saved virtual instrument configuration that contains a signal generator and the FFT analyzer – the two tools you need to use masking curves.

The test level in our sequence was 200 milliVolts, but I’ll start the signal generator at 70 milliVolts and 600 Hz. At this level, a couple of harmonics are visible. Now let’s add our masking curve. We’ll add a calculation and select “Masking Curve” from the dropdown list. Our calculation is now a masking curve. Its name is calculation one and our operand is the FFT1 live curve. Now on our graph we can see our fundamental tone, our masking curve, and we can see that harmonics 2 and 3 are well below the masking curve, suggesting they should be inaudible.

But now, watch what happens as we increase the test level. Around 150 mV is when perceptual Rub & Buzz really takes off. Now nearly all harmonics above the fifth up to the 20th or so are above the masking curve. Now when we bring this up to our final test level of 200 mV, nearly every harmonic up to the 30th is touching or above the masking curve, so we’d expect this to sound pretty bad. Let’s take a quick listen… and as we would expect, we can hear a lot of distortion.  

Finally, I’m going to remove the cursor and increase the frequency up to the point where the measured EPRB in our sequence should drop down. It’s doing some averaging, lets wait for it to settle. Now we can see at 800 hertz things have calmed down quite a bit. There’s still some visible harmonics but they’re pretty much at or below the masking curve. Let’s take it up to a kilohertz, now all our harmonics are below the masking curve and we should have a nice pure tone when we listen to it. 

So there’s a look at how one might use this new feature for failure analysis on a production line. It also has R&D applications, such as monitoring the effects of component size and quality during product development—for example, the contributions of the voice coil and magnet system to harmonic distortion. To learn more, check out the SoundCheck manual.

https://www.listeninc.com/wp/media/2025/07/Masking-Curves-Blog-TN-1.png 1080 1080 Julius Wijono https://www.listeninc.com/wp/media/logo.png Julius Wijono2025-07-22 07:00:342026-08-27 13:58:46Using Masking Curves for Measurement Insights

The NEW AudioConnect 8×8™ Audio Interface

July 18, 2025/in Blog, Product Demo Videos/by Julius Wijono

Introducing AudioConnect 8×8, our latest audio interface engineered specifically for test and measurement applications. With 8 analog inputs and 8 outputs, expandable up to 32 in/32 out channels, this powerful, interface is ideal for audio test environments such as microphone arrays, loudspeaker directivity measurements, and automotive acoustic testing. It supports sample rates up to 192 kHz and offers built-in constant voltage and constant current power for a wide range of transducers, including SCM and IEPE microphones, accelerometers, and couplers. This eliminates the need for external power supplies and simplifies your setup.In this video, we’ll demonstrate its key features: secure BNC connections, selectable input gain with overload indicators, TEDS support for faster calibration, input monitoring, and seamless integration with SoundCheck software. You’ll also see how its configuration can be locked into test sequences to ensure consistency across labs and production lines.With simple setup and calibration, and fast configuration across multiple stations, AudioConnect 8×8 brings accuracy, control, and scalability to your audio testing workflow. Watch now to see how it can optimize your setup and improve efficiency in both R&D and manufacturing environments.

AudioConnect 8×8™ Product Page

An introduction and overview to the AudioConnect 8×8™.

Additional Resources for SoundCheck

Detailed explanations of how to use SoundCheck can be found in the SoundCheck manual.

Video Transcript: The NEW AudioConnect 8×8™ Audio Interface

AudioConnect 8 by 8 is our first 8 in, 8 out audio interface that can be expanded up to 32 in, 32 out channels. Like our other interfaces, it’s specifically designed for audio measurements, with a host of design features to simplify your measurements and optimize your performance.

Let’s take a look.

On the front here we have our 8 analog input and output channels. These support sample rates up to 192 kHz so it’s great for high-resolution measurements. BNC connectors are used for secure cable connection and there are no knobs or buttons on the front panel.  All the inputs provide both constant voltage for our SCM microphones and constant current for IEPE microphones and accelerometers. This means you can directly connect a wide range of transducers –  microphones, head and torso simulators, couplers, test heads etc. Because you don’t need an additional power supply, this saves money especially if you are using a lot of channels for microphone arrays.  Each input channel has several selectable gain options from -20 to +30dB, and includes level and overload indicators to ensure you’re operating within the optimal dynamic range. TEDS support is also included, which speeds the transducer calibration setup. 

One other thing that’s pretty nice about the inputs is that you can monitor any of them if you want to listen to the response signal. In SoundCheck, you can assign an output to any input, then you can connect a headphone or loudspeaker on that output to monitor it.

Now let’s take a look at the back. Here you’ll see two power options – either a regular 100 to 240V supply, or a 12V DC supply which means that you can power it from a car or power bank out in the field. There’s S/PDIF in and out for a digital signal – BNC connectors again – and a USB-C connection to the computer.

Here we have our expansion ports. These 4 connectors let us synchronize up to 4 AudioConnect 8x8s together for a total of up to 32 input and output channels.  I can plug in these 3 units to my master unit here, connect the master unit to the computer, and now I have 32 synchronized channels, and this is something you can’t do with most other interfaces.

This feature is really useful if you’re making directivity measurement with a large microphone array, or measuring large speaker arrays, or even making automotive measurements with a large number of microphones or speakers. 

You’ll notice there are no physical knobs or buttons on the unit. All the functionality is controlled by SoundCheck to eliminate the risk of accidental gain or configuration changes. If you configure the hardware as part of a test sequence, it can’t be changed without editing the sequence. This means if you’re sharing sequences within your organization or with manufacturing partners, you can be 100% sure all the audio interface settings are correct and the tests are run exactly to your specifications.

Like our other hardware, setup is quick and easy. All channels are internally routed, so the only external connection required is a single USB cable to your computer. The device is supplied fully-calibrated, and when it’s connected to SoundCheck, the software automatically reads the calibration data from the firmware. This ensures a fully calibrated signal path with no manual input of sensitivity (Vp) values. You can see here the interface also auto-populates the input channels with appropriate sampling rates. It can also read and apply TEDS data if your microphones or accelerometers provide that.

It’s also quick and easy to setup multiple production line stations. Once you’ve configured it once, you can copy that configuration and each computer will automatically recognize the specific device connected to it. This also makes it easy to replace interfaces without recalibrating the signal path.

To learn more, check out the full specs on our website, www.listeninc.com, or contact your local sales engineer or rep for an in-person demo or pricing.

https://www.listeninc.com/wp/media/2025/07/AudioConnect-8x8-TN.png 1080 1920 Julius Wijono https://www.listeninc.com/wp/media/logo.png Julius Wijono2025-07-18 07:00:202026-08-28 14:27:38The NEW AudioConnect 8×8™ Audio Interface

How to View Frequency in the Time Domain

July 8, 2025/in Blog, SoundCheck Tips Videos/by Julius Wijono

Curious how to view frequency directly in the time domain? In this video, we demonstrate how to use SoundCheck’s new Stimulus Frequency Cursor to pinpoint the frequency of transient events on recorded waveforms.

Additional Resources for SoundCheck

Detailed explanations of how to use SoundCheck can be found in the SoundCheck manual.

Video Transcript: How to View Frequency in the Time Domain

Today, I’m going to show you how to use SoundCheck’s Stimulus Frequency Cursor. This is a new feature we introduced in SoundCheck 23 that lets you see the exact frequency of any transient event on a recorded time waveform.

This feature can be used with:

  • Frequency Stepped Sweeps/Stweeps 
  • Frequency Log Sweep
  • Log Amplitude Sweep
  • Two-tone options
    • Intermodulation
    • Difference Frequency
  • Loose Particle and Enhanced Loose Particle Waveform and Time Envelopes

Here I have a short sequence I’ll use for demonstration purposes. The first part uses play and record acquisition and harmonic track analysis, and the second part recalls some enhanced loose particle waveforms.

Let’s start the sequence and take a look at our recorded time waveform. We can see in our table here that the record delay is 1.11 milliseconds and we can clearly see that down here in the waveform graph. Let’s expand this graph so we can look at this new feature.

Now one thing that’s important to know when you’re using this feature, is that delay compensation must be added to our waveform. If I try to enable the stimulus frequency cursor now, you can see that it’s grayed out.

So, I’ll just add delay compensation in our analysis step…  you can see here on the delay tab there’s a new function called “output auto-delayed waveforms” so I’ll select this and apply. If you keep your eye on the memory list and you’ll see a new waveform appear with the name “auto delayed recorded time waveform”.

Let’s bring this over to our waveform graph, and we can see this has essentially moved the start

of the recorded time waveform to time equals zero. Let’s remove the original one. Now we’ve done that, I can drop my stimulus frequency cursor onto this recorded time waveform. We can now see that we have the time and magnitude coordinates for our auto-delayed waveform, and here we have the frequency value. You can see these values changing as I drag the cursor across the waveform. 

Now let’s take a look at how we can use the stimulus frequency cursor with loose particle analysis. We’ll continue running the sequence and it’s going to recall a previously recorded time waveform and perform an enhanced loose particle analysis on it.

Here we’ve got the recorded time waveform and down below is the enhanced loose particle waveform. 

Let’s add our stimulus frequency cursor to the enhanced loose particle waveform. You can see that it’s already enabled – that’s because by default the ELP waveform is already delay compensated so we can jump right in and enable our stimulus frequency cursor and see the readout here. I can also use some of the other cursor functions like snap to max to see where the largest transient is on the graph – it’s telling me it’s at 200 hertz. Again, I can drag the cursor and see the frequencies change… we can see just by looking at it that the largest concentration of loose particle transient events occurs between 132 hertz and 250 hertz so that might help us understand a little bit more about the behavior of the loudspeaker.

So, that’s how we use the stimulus frequency cursor. If you want to learn more about this feature, check out the SoundCheck manual, or ask your sales engineer.

https://www.listeninc.com/wp/media/2025/07/Frequency-Time-Domain-Blog-TN.png 1080 1080 Julius Wijono https://www.listeninc.com/wp/media/logo.png Julius Wijono2025-07-08 11:44:392026-08-27 14:22:14How to View Frequency in the Time Domain

Auto-incrementing Signal Test Levels in SoundCheck

June 24, 2025/in Blog, SoundCheck Tips Videos/by Julius Wijono

Explore how to automatically increment signal test levels using SoundCheck’s loop functionality. This technique is perfect for displaying measurements across a range of signal test levels, determining voltage-to-SPL relationships, or assessing distortion once a target level is reached.

Additional Resources for SoundCheck

Detailed explanations of how to use SoundCheck can be found in the SoundCheck manual.

Video Transcript: Auto-incrementing Signal Test Levels in SoundCheck

SoundCheck’s loop functionality offers a lot of flexibility, for example you can use it with sequence logic for pass/fail or yes/no scenarios, or to run tests in a loop and perform statistical analysis. 

However, one of my favorite applications of this feature is for auto-incrementing the test signal level. This is useful, for example, to display measurements across different test signal levels, to ascertain the  voltage required to achieve a specific sound pressure level or to measure distortion of a device once a desired sound pressure level is achieved. 

In SoundCheck, when you create a loop, a memory list value called “loop index” is created and the steps are indented  in the sequence editor. 

In the step configuration window we can control the level at which the tests starts, and the increment amount. Here, I’ve  set it to start at 100mV and increment in 100mV steps. This loop runs a total of 5 times and I have a table to reflect the test level for each cycle. 

Now, let’s make sure our stimulus is using our incremental level. Open the stimulus step, and select “Memory List Selection” in the “level” section. Click on the dropdown and navigate to “loop index”, and change the axis to the Y-axis selection. You may get a prompt after doing this to disable the preload stimulus when using a memory list selection to control your test level. We do this by unchecking the “Preload Stimulus” option in the  “Overall Sequence” configuration. 

Now let’s run the sequence… 

This table here displays the test level at every loop and our frequency responses, THD measurements, and recorded time waveforms are displayed for all 5 test runs. 

Check it out, and if you have questions, please contact the Listen Support team.

https://www.listeninc.com/wp/media/2025/06/Signal-Test-Levels-Blog-TN.png 1080 1080 Julius Wijono https://www.listeninc.com/wp/media/logo.png Julius Wijono2025-06-24 05:00:222026-08-27 14:18:19Auto-incrementing Signal Test Levels in SoundCheck

SoundCheck 23 New Features

June 18, 2025/in Blog, Product Demo Videos, SoundCheck Functionality Videos/by Julius Wijono

Check out our short demo video for a brief introduction to all the new features in SoundCheck 23. From real-time masking curves and multichannel oscilloscope support to ISO 532-3 loudness measurements and enhanced sequence editing, this release is packed with powerful features for both R&D and production.

SoundCheck 23 New Features

Ready to try SoundCheck 23 for yourself?

If you are ready to upgrade your system to SoundCheck 23, or want to discuss how SoundCheck 23 can help your testing needs, contact your local sales engineer or sales@listeninc.com with any questions.

Learn more

Download the PDF for SoundCheck 23 New Features here.

For detailed information, visit the SoundCheck What’s New page.

To see some of the other great features, algorithms, and functionality from previous SoundCheck versions, check out our version timeline to learn more about Listen’s 20 years of innovation.

SoundCheck 23 New Features Intro

Hello, I’m Steve Temme and today I’m going to demonstrate the new features in SoundCheck 23. This release is a big one for us as this year marks our 30th anniversary. When I created the first version of SoundCheck from the corner of my bedroom back in 1995, I had no idea that it would evolve into such a sophisticated audio test toolkit, or that some of those early algorithms I developed would go on to become industry standard test methods. 

This new release offers new functionality and performance improvements for both R&D and production testing. These include real-time tonal masking curves for detailed perceptual audio analysis, a new multi-channel oscilloscope, a new time/ frequency cursor for recorded Stweep waveforms, and support for AudioConnect 8×8, our newest multi-channel interface. We’ve also improved performance, particularly for graphical display, and updated the sequence editor for faster test development. Let’s take a look.

https://www.listeninc.com/wp/media/2025/06/New-Features-Thumbnail-1.png 1080 1920 Julius Wijono https://www.listeninc.com/wp/media/logo.png Julius Wijono2025-06-18 15:33:062026-08-21 12:34:27SoundCheck 23 New Features
Page 3 of 22‹12345›»

Audio Measurement Expertise


How Changing Industry Needs are Shaping Audio Test and Measurement

Smarter SoundCheck Sequences with Loops and Logic

Audio Basics: Polarity

How to Measure: Haptics

The Value of Big Data

Audio Basics: Phase Response

view all

Latest News


2026 End Of Year Promotions

Celebrating 30 years: Listening – The Secret Of Our Success

Automotive Test Sequence Including BSR, Max SPL and Frequency Response

Listen Introduces AudioConnect 2, a New Portable Dual-Channel Audio Interface

SoundCheck 21 Brings Enhanced Loose Particle Detection, Multichannel FFT, Metadata, Sequence Protection and more


Audio Measurement Expertise – Delivered Monthly

 

ABOUT LISTEN INC

Listen is a global leader in audio measurement and analysis, with over 30 years’ experience developing innovative test methods and algorithms. SoundCheck, our powerful software-based audio analyzer, pairs with our test interfaces, precision microphones, and accessories to offer a complete solution for testing loudspeakers, headphones, microphones, smart devices, communication systems, hearing aids, automotive audio, and more. Trusted by engineers worldwide, Listen delivers the accuracy and flexibility essential for modern audio testing, from the R&D lab to the production line.

PRODUCTS
APPLICATIONS
SUPPORT
RESOURCES
NEWS & EVENTS
ABOUT

CONNECT

YouTube
LinkedIn
LinkedIn
Share
Instagram

Copyright © Listen, Inc.   |   Privacy Policy   |   AI Disclosure
  • Instagram
  • LinkedIn
  • Youtube
  • Mail
Scroll to top