Complete End-of-Line Speaker Test (includes ePRB and eLP)
This sequence is an example of the many types of tests that can be performed quickly and simultaneously on a loudspeaker production line. A stepped sine sweep (StweepTM) from 20 kHz to 50 Hz is played through the speaker under test and measured via two channels of the audio interface. A calibrated reference microphone is connected to one of the channels and an impedance reference built into the SC Amp or AmpConnect is connected to the other. A HarmonicTrak™ Analysis step analyzes the recorded waveform from the reference microphone and outputs Frequency Response, THD, Normalized Rub & Buzz, Perceptual Rub & Buzz (ePRB), Loose Particle Prominence and Threshold (eLP) and Polarity. A Post-Processing step calculates the Average Sensitivity from 100 – 10kHz. A second Analysis step analyzes the recorded waveform from the impedance reference and outputs a curve of impedance versus frequency. A Post Processing step performs a curve fit of the impedance curve and calculates the max impedance (Zmax), precise resonance frequency (f0), and the quality factor (Q) of the resonance peak. All measurements and parameters are tested against limits in Limit steps. All these limits can be adjusted to suit your own DUT.








This sequence measures the anechoic response of a loudspeaker in an ordinary room using both a near field and time-windowed far field measurement “spliced” together to cover the full bandwidth of the loudspeaker’s response from 20 Hz to 40 kHz. First, the microphone is placed very close to the low frequency driver (less than an inch from the woofer), and the near field frequency response measured using a 1/12th octave stepped sine). Next, the microphone is placed in the far field and the frequency response is measured using a continuous log sweep with the Time Selective Response analysis algorithm. An option is available for measuring a ported loudspeaker. The sequence displays both measurements on a graph, showing the overlap range where the measurements are equal. From this, the user selects the precise frequency at which to splice the two halves of the measurements together to obtain the full range free field response of the loudspeaker.